Abstract

Education and diagnostic tests capable of early detection represent our most effective means of preventing transmission of human immunodeficiency virus (HIV). The importance of early detection is underlined by studies demonstrating increased life expectancy following early initiation of antiviral treatment. The Elecsys® HIV combi PT assay is a fourth-generation antigen–antibody combination assay developed to allow earlier detection of seroconversion, and to have increased sensitivity and improved specificity. We aimed to determine how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay’s specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors. Samples were identified as positive by the Elecsys® assay 4.9 days after a positive polymerase chain reaction result (as determined by the panel supplier), which was earlier than the 5.3–7.1 days observed with comparators. The analytical sensitivity of the Elecsys® HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the comparator assays. In addition, the Elecsys® assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. Overall, the specificity of the Elecsys® assay was 99.88 % using samples from blood donors and 99.81 % when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys® HIV combi PT assay is a sensitive and specific assay that has been granted the CE mark according to Directive 2009/886/EC.
Literature
2.
go back to reference Hemelaar J, Gouws E, Ghys PD, Osmanov S (2006) Global and regional distribution of HIV-1 genetic subtypes and recombinants in 2004. AIDS 20:W13–W23PubMedCrossRef Hemelaar J, Gouws E, Ghys PD, Osmanov S (2006) Global and regional distribution of HIV-1 genetic subtypes and recombinants in 2004. AIDS 20:W13–W23PubMedCrossRef
3.
go back to reference Fanales-Belasio E, Raimondo M, Suligoi B, Butt S (2010) HIV virology and pathogenetic mechanisms of infection: a brief overview. Ann Ist Super Sanita 46:5–14PubMed Fanales-Belasio E, Raimondo M, Suligoi B, Butt S (2010) HIV virology and pathogenetic mechanisms of infection: a brief overview. Ann Ist Super Sanita 46:5–14PubMed
4.
go back to reference Plantier JC, Leoz M, Dickerson JE, De Oliveira F, Cordonnier F, Lemée V, Damond F, Robertson DL, Simon F (2009) A new human immunodeficiency virus derived from gorillas. Nat Med 15:871–872PubMedCrossRef Plantier JC, Leoz M, Dickerson JE, De Oliveira F, Cordonnier F, Lemée V, Damond F, Robertson DL, Simon F (2009) A new human immunodeficiency virus derived from gorillas. Nat Med 15:871–872PubMedCrossRef
5.
go back to reference McGowan JP, Shah SS (2000) Prevention of perinatal HIV transmission during pregnancy. J Antimicrob Chemother 46:657–668PubMedCrossRef McGowan JP, Shah SS (2000) Prevention of perinatal HIV transmission during pregnancy. J Antimicrob Chemother 46:657–668PubMedCrossRef
6.
go back to reference Kleinman SH, Lelie N, Busch MP (2009) Infectivity of human immunodeficiency virus-1, hepatitis C virus, and hepatitis B virus and risk of transmission by transfusion. Transfusion 49:2454–2489PubMedCrossRef Kleinman SH, Lelie N, Busch MP (2009) Infectivity of human immunodeficiency virus-1, hepatitis C virus, and hepatitis B virus and risk of transmission by transfusion. Transfusion 49:2454–2489PubMedCrossRef
7.
go back to reference Tang S, Zhao J, Wang A, Viswanath R, Harma H, Little RF, Yarchoan R, Stramer SL, Nyambi PN, Lee S, Wood O, Wong EY, Wang X, Hewlett IK (2010) Characterization of immune responses to capsid protein p24 of human immunodeficiency virus type 1 and implications for detection. Clin Vaccine Immunol 17:1244–1251PubMedCrossRef Tang S, Zhao J, Wang A, Viswanath R, Harma H, Little RF, Yarchoan R, Stramer SL, Nyambi PN, Lee S, Wood O, Wong EY, Wang X, Hewlett IK (2010) Characterization of immune responses to capsid protein p24 of human immunodeficiency virus type 1 and implications for detection. Clin Vaccine Immunol 17:1244–1251PubMedCrossRef
8.
go back to reference Miller WC, Rosenberg NE, Rutstein SE, Powers KA (2010) Role of acute and early HIV infection in the sexual transmission of HIV. Curr Opin HIV AIDS 5:277–282PubMedCrossRef Miller WC, Rosenberg NE, Rutstein SE, Powers KA (2010) Role of acute and early HIV infection in the sexual transmission of HIV. Curr Opin HIV AIDS 5:277–282PubMedCrossRef
9.
go back to reference Thompson MA, Aberg JA, Cahn P, Montaner JSG, Rizzardini G, Telenti A, Gatell JM, Günthard HF, Hammer SM, Hirsch MS, Jacobsen DM, Reiss P, Richman DD, Volberding PA, Yeni P, Schooley RT (2010) Antiretroviral treatment of adult HIV infection: 2010 recommendations of the international AIDS society USA Panel. JAMA 304:321–333PubMedCrossRef Thompson MA, Aberg JA, Cahn P, Montaner JSG, Rizzardini G, Telenti A, Gatell JM, Günthard HF, Hammer SM, Hirsch MS, Jacobsen DM, Reiss P, Richman DD, Volberding PA, Yeni P, Schooley RT (2010) Antiretroviral treatment of adult HIV infection: 2010 recommendations of the international AIDS society USA Panel. JAMA 304:321–333PubMedCrossRef
10.
go back to reference Losina E, Schackman BR, Sadownik SN, Gebo KA, Walensky RP, Chiosi JJ, Weinstein MC, Hicks PL, Aaronson WH, Moore RD, Paltiel AD, Freedberg KA (2009) Racial and sex disparities in life expectancy losses among HIV-infected persons in the United States: impact of risk behavior, late initiation, and early discontinuation of antiretroviral therapy. Clin Infect Dis 49:1570–1578PubMedCrossRef Losina E, Schackman BR, Sadownik SN, Gebo KA, Walensky RP, Chiosi JJ, Weinstein MC, Hicks PL, Aaronson WH, Moore RD, Paltiel AD, Freedberg KA (2009) Racial and sex disparities in life expectancy losses among HIV-infected persons in the United States: impact of risk behavior, late initiation, and early discontinuation of antiretroviral therapy. Clin Infect Dis 49:1570–1578PubMedCrossRef
11.
go back to reference Weber B, Orazi B, Ranieri A, Thorstensson R, Bürgisser P, Mühlbacher A, Areal C, Eiras A, Villaescusa R, Camacho R, Ciogo I, Roth HJ, Zahn I, Bartel J, Bossi V, Piro F, Atamasirikul K, Permpikul P, Webber L, Singh S (2006) Multicenter evaluation of a new 4th generation HIV screening assay Elecsys® HIV combi. Clin Lab 52:463–473PubMed Weber B, Orazi B, Ranieri A, Thorstensson R, Bürgisser P, Mühlbacher A, Areal C, Eiras A, Villaescusa R, Camacho R, Ciogo I, Roth HJ, Zahn I, Bartel J, Bossi V, Piro F, Atamasirikul K, Permpikul P, Webber L, Singh S (2006) Multicenter evaluation of a new 4th generation HIV screening assay Elecsys® HIV combi. Clin Lab 52:463–473PubMed
13.
go back to reference Malm K, von Sydow M, Andersson S (2009) Performance of the three automated fourth-generation combined HIV antigen/antibody assays in large-scale screening of blood donors and clinical samples. Transfus Med 19:78–88PubMedCrossRef Malm K, von Sydow M, Andersson S (2009) Performance of the three automated fourth-generation combined HIV antigen/antibody assays in large-scale screening of blood donors and clinical samples. Transfus Med 19:78–88PubMedCrossRef
14.
go back to reference Roche (2010) Elecsys® HIV combi PT assay package insert Roche (2010) Elecsys® HIV combi PT assay package insert
19.
go back to reference Couroucé AM and groupe de travail Rétrovirus de la S.F.T.S (1999) Tests de dépistage combiné des anticorps anti-VIH et de l’antigène p24. Gaz Transfus Sang 155:4–18 Couroucé AM and groupe de travail Rétrovirus de la S.F.T.S (1999) Tests de dépistage combiné des anticorps anti-VIH et de l’antigène p24. Gaz Transfus Sang 155:4–18
20.
go back to reference Weber B, Berger A, Rabenau H, Doerr HW (2002) Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra. J Clin Microbiol 40:1420–1426PubMedCrossRef Weber B, Berger A, Rabenau H, Doerr HW (2002) Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra. J Clin Microbiol 40:1420–1426PubMedCrossRef
21.
go back to reference Ly TD, Ebel A, Faucher V, Fihman V, Laperche S (2007) Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays? J Virol Methods 143:86–94PubMedCrossRef Ly TD, Ebel A, Faucher V, Fihman V, Laperche S (2007) Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays? J Virol Methods 143:86–94PubMedCrossRef
22.
go back to reference Kwon JA, Yoon SY, Lee CK, Lim CS, Lee KN, Sung HJ, Brennan CA, Devare SG (2006) Performance evaluation of three automated human immunodeficiency virus antigen–antibody combination immunoassays. J Virol Methods 133:20–26PubMedCrossRef Kwon JA, Yoon SY, Lee CK, Lim CS, Lee KN, Sung HJ, Brennan CA, Devare SG (2006) Performance evaluation of three automated human immunodeficiency virus antigen–antibody combination immunoassays. J Virol Methods 133:20–26PubMedCrossRef
23.
go back to reference Miedouge M, Grèze M, Bailly A, Izopet J (2011) Analytical sensitivity of four HIV combined antigen/antibody assays using the p24 WHO standard. J Clin Virol 50:57–60PubMedCrossRef Miedouge M, Grèze M, Bailly A, Izopet J (2011) Analytical sensitivity of four HIV combined antigen/antibody assays using the p24 WHO standard. J Clin Virol 50:57–60PubMedCrossRef
24.
go back to reference Ly TD, Martin L, Daghfal D, Sandridge A, West D, Bristow R, Chalouas L, Qui X, Lou SC, Hunt JC, Schochetman G, Davare SG (2001) Seven human immunodeficiency virus (HIV) antigen–antibody combination assays: evaluation of HIV seroconversion sensitivity and subtype detection. J Clin Microbiol 39:3122–3128PubMedCrossRef Ly TD, Martin L, Daghfal D, Sandridge A, West D, Bristow R, Chalouas L, Qui X, Lou SC, Hunt JC, Schochetman G, Davare SG (2001) Seven human immunodeficiency virus (HIV) antigen–antibody combination assays: evaluation of HIV seroconversion sensitivity and subtype detection. J Clin Microbiol 39:3122–3128PubMedCrossRef
25.
go back to reference Henquell C, Jacomet C, Antoniotti O, Chaib A, Regagnon C, Brunet S, Peigue-Lafeuille H, Barin F (2008) Difficulties in diagnosing group O human immunodeficiency virus type 1 acute primary infection. J Clin Microbiol 46:2453–2456PubMedCrossRef Henquell C, Jacomet C, Antoniotti O, Chaib A, Regagnon C, Brunet S, Peigue-Lafeuille H, Barin F (2008) Difficulties in diagnosing group O human immunodeficiency virus type 1 acute primary infection. J Clin Microbiol 46:2453–2456PubMedCrossRef
26.
go back to reference Nie J, Song A, Xu S, Li X, Want Y (2010) The effect of human immunodeficiency virus type 1 (HIV 1) gp41 variability on antibody detection. Arch Virol 155:1813–1822PubMedCrossRef Nie J, Song A, Xu S, Li X, Want Y (2010) The effect of human immunodeficiency virus type 1 (HIV 1) gp41 variability on antibody detection. Arch Virol 155:1813–1822PubMedCrossRef
27.
go back to reference Speers D, Phillips P, Dyer J (2005) Combination assay detecting both human immunodeficiency virus (HIV) p24 antigen and anti-HIV antibodies opens a second diagnostic window. J Clin Microbiol 43:5397–5399PubMedCrossRef Speers D, Phillips P, Dyer J (2005) Combination assay detecting both human immunodeficiency virus (HIV) p24 antigen and anti-HIV antibodies opens a second diagnostic window. J Clin Microbiol 43:5397–5399PubMedCrossRef
28.
go back to reference Niederhauser C, Ströhle A, Stolz M, Müller F, Tinguely C (2009) The risk of a second diagnostic window with 4th generation HIV assays: two cases. J Clin Virol 45:367–369PubMedCrossRef Niederhauser C, Ströhle A, Stolz M, Müller F, Tinguely C (2009) The risk of a second diagnostic window with 4th generation HIV assays: two cases. J Clin Virol 45:367–369PubMedCrossRef
29.
go back to reference Gürtler L, Mühlbacher A, Michl U, Hofmann H, Paggi GG, Bossi V, Thorstensson R, Villaescusa RG, Eiras A, Hernandez JH, Melchior W, Donié F, Weber B (1998) Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay. J Virol Methods 75:27–38PubMedCrossRef Gürtler L, Mühlbacher A, Michl U, Hofmann H, Paggi GG, Bossi V, Thorstensson R, Villaescusa RG, Eiras A, Hernandez JH, Melchior W, Donié F, Weber B (1998) Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay. J Virol Methods 75:27–38PubMedCrossRef
30.
go back to reference Weber B, Gürtler L, Thorstensson R, Michl U, Mühlbacher A, Bürgisser P, Villaescusa R, Eiras A, Gabriel C, Stekel H, Tanprasert S, Oota S, Silvestre M-J, Marques C, Laderia M, Rabenau H, Berger A, Schmitt U, Melchior W (2002) Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity. J Clin Microbiol 40:1938–1946PubMedCrossRef Weber B, Gürtler L, Thorstensson R, Michl U, Mühlbacher A, Bürgisser P, Villaescusa R, Eiras A, Gabriel C, Stekel H, Tanprasert S, Oota S, Silvestre M-J, Marques C, Laderia M, Rabenau H, Berger A, Schmitt U, Melchior W (2002) Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity. J Clin Microbiol 40:1938–1946PubMedCrossRef
31.
go back to reference Pumarola T, Freeman J, Saxton E, Dillon P, Bal T, van Helden J (2010) Performance evaluation of the ADVIA Centaur® HIV Ag/Ab Combo assay. J Virol Methods 170:16–20PubMedCrossRef Pumarola T, Freeman J, Saxton E, Dillon P, Bal T, van Helden J (2010) Performance evaluation of the ADVIA Centaur® HIV Ag/Ab Combo assay. J Virol Methods 170:16–20PubMedCrossRef
32.
go back to reference Sickinger E, Jonas G, Yem AW, Goller A, Stieler M, Brennan C, Hausmann M, Schochetman G, Devare SG, Hunt JC, Kapprell HP, Bryant JD (2008) Performance evaluation of the new fully automated human immunodeficiency virus antigen–antibody combination assay designed for blood screening. Transfusion 48:584–593PubMedCrossRef Sickinger E, Jonas G, Yem AW, Goller A, Stieler M, Brennan C, Hausmann M, Schochetman G, Devare SG, Hunt JC, Kapprell HP, Bryant JD (2008) Performance evaluation of the new fully automated human immunodeficiency virus antigen–antibody combination assay designed for blood screening. Transfusion 48:584–593PubMedCrossRef
Metadata
Title
Performance evaluation of a new fourth-generation HIV combination antigen–antibody assay
Authors
A. Mühlbacher
H. Schennach
J. van Helden
T. Hebell
G. Pantaleo
P. Bürgisser
C. Cellerai
P. Permpikul
M. I. Rodriguez
A. Eiras
F. Alborino
P. Cunningham
M. Axelsson
S. Andersson
O. Wetlitzky
C. Kaiser
P. Möller
G. de Sousa
Publication date
01-02-2013
Publisher
Springer-Verlag
Published in
Medical Microbiology and Immunology / Issue 1/2013
Print ISSN: 0300-8584
Electronic ISSN: 1432-1831
DOI
https://doi.org/10.1007/s00430-012-0250-5

Other articles of this Issue 1/2013

Medical Microbiology and Immunology 1/2013 Go to the issue