Skip to main content
Top
Published in: Langenbeck's Archives of Surgery 7/2017

Open Access 01-11-2017 | ORIGINAL ARTICLE

Localization of parathyroid adenomas using 11C-methionine pet after prior inconclusive imaging

Authors: Milou E Noltes, Annemieke M Coester, Anouk N A van der Horst-Schrivers, Bart Dorgelo, Liesbeth Jansen, Walter Noordzij, Clara Lemstra, Adrienne H Brouwers, Schelto Kruijff

Published in: Langenbeck's Archives of Surgery | Issue 7/2017

Login to get access

Abstract

Purpose

Minimally invasive parathyroidectomy (MIP) is the recommended treatment in primary hyperparathyroidism (pHPT) for which accurate preoperative localization is essential. The current imaging standard consists of cervical ultrasonography (cUS) and MIBI-SPECT/CT. 11C-MET PET/CT has a higher resolution than MIBI-SPECT/CT. The aim of this study was to determine the diagnostic performance of 11C-MET PET/CT after initial inconclusive or negative localization.

Methods

We performed a retrospective single center cohort study of patients with pHPT undergoing parathyroid surgery after prior negative imaging and later localization by means of 11C-MET PET/CT between 2006 and 2014. Preoperative localization by 11C-MET PET/CT was compared with later surgical localization, intraoperative quick PTH (IOPTH), duration of surgery, histopathology, and follow-up data. Also, differences in duration of surgery between the groups with and without correct preoperative localization were analyzed.

Results

In 18/28 included patients a positive 11C-MET-PET/CT result corresponded to the surgical localized adenoma (64%). In 3/28 patients imaging was false positive and no adenoma was found. In 7/28 patients imaging was false negative at the side of the surgically identified adenoma. Sensitivity of 11C-MET PET/CT was 72% (18/25). Duration of surgery of correctly localized patients was significantly shorter compared to falsely negative localized patients (p = 0.045).

Conclusion

In an intention to treat 11C-MET-PET/CT correctly localized the parathyroid adenoma in 18/28 (64%) patients, after previous negative imaging. A preoperatively correct localized adenoma leads to a more focused surgical approach (MIP) potentially reducing duration of surgery and potentially healthcare costs.
Literature
2.
go back to reference Clark OH, Duh Q, Kebebew E (2005) Textbook of endocrine surgery, 2nd edition ed. Elsevier Saunders, Philadelphia, pp 366–371 Clark OH, Duh Q, Kebebew E (2005) Textbook of endocrine surgery, 2nd edition ed. Elsevier Saunders, Philadelphia, pp 366–371
4.
go back to reference Hindié E, Ugur O, Fuster D, O'Doherty M, Grassetto G, Ureña P, Kettle A, Gulec SA, Pons F, Rubello D, Parathyroid Task Group of the EANM (2009) 2009 EANM parathyroid guidelines. Eur J Nucl Med Mol Imaging 36:1201–1216. doi:10.1007/s00259-009-1131-z CrossRefPubMed Hindié E, Ugur O, Fuster D, O'Doherty M, Grassetto G, Ureña P, Kettle A, Gulec SA, Pons F, Rubello D, Parathyroid Task Group of the EANM (2009) 2009 EANM parathyroid guidelines. Eur J Nucl Med Mol Imaging 36:1201–1216. doi:10.​1007/​s00259-009-1131-z CrossRefPubMed
5.
go back to reference Wei WJ, Shen CT, Song HJ, Qiu ZL, Luo QY (2015) Comparison of SPET/CT, SPET and planar imaging using 99mTc-MIBI as independent techniques to support minimally invasive parathyroidectomy in primary hyperparathyroidism: a meta-analysis. Hell J Nucl Med 18:127–135. doi:10.1967/s002449910207 PubMed Wei WJ, Shen CT, Song HJ, Qiu ZL, Luo QY (2015) Comparison of SPET/CT, SPET and planar imaging using 99mTc-MIBI as independent techniques to support minimally invasive parathyroidectomy in primary hyperparathyroidism: a meta-analysis. Hell J Nucl Med 18:127–135. doi:10.​1967/​s002449910207 PubMed
6.
go back to reference García-Talavera P, Díaz-Soto G, Montes AA, Villanueva JG, Cobo A, Gamazo C, Ruiz MÁ, González-Selma ML (2016) Contribution of early SPECT/CT to 99mTc-MIBI double phase scintigraphy in primary hyperparathyroidism: Diagnostic value and correlation between uptake and biological parameters. Rev Esp Med Nucl Imagen Mol S2253-654X:00043–00043. doi:10.1016/j.remn.2016.03.001 García-Talavera P, Díaz-Soto G, Montes AA, Villanueva JG, Cobo A, Gamazo C, Ruiz MÁ, González-Selma ML (2016) Contribution of early SPECT/CT to 99mTc-MIBI double phase scintigraphy in primary hyperparathyroidism: Diagnostic value and correlation between uptake and biological parameters. Rev Esp Med Nucl Imagen Mol S2253-654X:00043–00043. doi:10.​1016/​j.​remn.​2016.​03.​001
7.
go back to reference Lee GS, McKenzie TJ, Mullan BP, Farley DR, Thompson GB, Richards ML (2016) A multimodal imaging protocol,123I/99Tc-sestamibi, SPECT, and SPECT/CT, in primary hyperparathyroidism adds limited benefit for preoperative localization. World J Surg 40:589–594. doi:10.1007/s00268-015-3389-6 CrossRefPubMed Lee GS, McKenzie TJ, Mullan BP, Farley DR, Thompson GB, Richards ML (2016) A multimodal imaging protocol,123I/99Tc-sestamibi, SPECT, and SPECT/CT, in primary hyperparathyroidism adds limited benefit for preoperative localization. World J Surg 40:589–594. doi:10.​1007/​s00268-015-3389-6 CrossRefPubMed
8.
go back to reference Joliat GR, Demartines N, Portmann L, Boubaker A, Matter M (2015) Successful minimally invasive surgery for primary hyperparathyroidism: influence of preoperative imaging and intraoperative parathyroid hormone levels. Langenbeck's Arch Surg 400:937–944. doi:10.1007/s00423-015-1358-z CrossRef Joliat GR, Demartines N, Portmann L, Boubaker A, Matter M (2015) Successful minimally invasive surgery for primary hyperparathyroidism: influence of preoperative imaging and intraoperative parathyroid hormone levels. Langenbeck's Arch Surg 400:937–944. doi:10.​1007/​s00423-015-1358-z CrossRef
9.
go back to reference Michaud L, Balogova S, Burgess A, Ohnona J, Huchet V, Kerrou K, Lefèvre M, Tassart M, Montravers F, Périé S, Talbot JN (2015) A pilot comparison of 18F-fluorocholine PET/CT, ultrasonography and 123I/99mTc-sestaMIBI dual-phase dual-isotope scintigraphy in the preoperative localization of hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism: influence of thyroid anomalies. Medicine 94:e1701. doi:10.1097/MD.0000000000001701 CrossRefPubMedPubMedCentral Michaud L, Balogova S, Burgess A, Ohnona J, Huchet V, Kerrou K, Lefèvre M, Tassart M, Montravers F, Périé S, Talbot JN (2015) A pilot comparison of 18F-fluorocholine PET/CT, ultrasonography and 123I/99mTc-sestaMIBI dual-phase dual-isotope scintigraphy in the preoperative localization of hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism: influence of thyroid anomalies. Medicine 94:e1701. doi:10.​1097/​MD.​0000000000001701​ CrossRefPubMedPubMedCentral
10.
go back to reference Krakauer M, Wieslander B, Myschetzky PS, Lundstrøm A, Bacher T, Sørensen CH, Trolle W, Nygaard B, Bennedbæk FN (2016) A prospective comparative study of parathyroid dual-phase scintigraphy, dual-isotope subtraction scintigraphy, 4D-CT, and ultrasonography in primary hyperparathyroidism. Clin Nucl Med 41:93–100. doi:10.1097/RLU.0000000000000988 CrossRefPubMed Krakauer M, Wieslander B, Myschetzky PS, Lundstrøm A, Bacher T, Sørensen CH, Trolle W, Nygaard B, Bennedbæk FN (2016) A prospective comparative study of parathyroid dual-phase scintigraphy, dual-isotope subtraction scintigraphy, 4D-CT, and ultrasonography in primary hyperparathyroidism. Clin Nucl Med 41:93–100. doi:10.​1097/​RLU.​0000000000000988​ CrossRefPubMed
11.
14.
go back to reference Sukan A, Reyhan M, Aydin M, Yapar AF, Sert Y, Canpolat T, Aktas A (2008) Preoperative evaluation of hyperparathyroidism: the role of dual-phase parathyroid scintigraphy and ultrasound imaging. Ann Nucl Med 22:123–131. doi:10.1007/s12149-007-0086-z CrossRefPubMed Sukan A, Reyhan M, Aydin M, Yapar AF, Sert Y, Canpolat T, Aktas A (2008) Preoperative evaluation of hyperparathyroidism: the role of dual-phase parathyroid scintigraphy and ultrasound imaging. Ann Nucl Med 22:123–131. doi:10.​1007/​s12149-007-0086-z CrossRefPubMed
16.
go back to reference Patel CN, Salahudeen HM, Lansdown M, Scarsbrook AF (2010) Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism. Clin Radiol 65:278–287. doi:10.1016/j.crad.2009.12.005 CrossRefPubMed Patel CN, Salahudeen HM, Lansdown M, Scarsbrook AF (2010) Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism. Clin Radiol 65:278–287. doi:10.​1016/​j.​crad.​2009.​12.​005 CrossRefPubMed
18.
go back to reference Otto D, Boerner AR, Hofmann M, Brunkhorst T, Meyer GJ, Petrich T, Scheumann GF, Knapp WH (2004) Pre-operative localisation of hyperfunctional parathyroid tissue with 11C-methionine PET. Eur J Nucl Med Mol Imaging 31:1405–1412. doi:10.1007/s00259-004-1610-1 CrossRefPubMed Otto D, Boerner AR, Hofmann M, Brunkhorst T, Meyer GJ, Petrich T, Scheumann GF, Knapp WH (2004) Pre-operative localisation of hyperfunctional parathyroid tissue with 11C-methionine PET. Eur J Nucl Med Mol Imaging 31:1405–1412. doi:10.​1007/​s00259-004-1610-1 CrossRefPubMed
19.
20.
go back to reference Chun IK, Cheon GJ, Paeng JC, Kang KW, Chung JK, Lee DS (2013) Detection and characterization of parathyroid adenoma/hyperplasia for preoperative localization: comparison between 11C-methionine PET/CT and99mTc-sestamibi scintigraphy. Nucl Med Mol Imaging 47:166–172. doi:10.1007/s13139-013-0212-x CrossRefPubMedPubMedCentral Chun IK, Cheon GJ, Paeng JC, Kang KW, Chung JK, Lee DS (2013) Detection and characterization of parathyroid adenoma/hyperplasia for preoperative localization: comparison between 11C-methionine PET/CT and99mTc-sestamibi scintigraphy. Nucl Med Mol Imaging 47:166–172. doi:10.​1007/​s13139-013-0212-x CrossRefPubMedPubMedCentral
21.
go back to reference Greenspan BS, Dillehay G, Intenzo C, Lavely WC, O'Doherty M, Palestro CJ, Scheve W, Stabin MG, Sylvestros D, Tulchinsky M (2012) SNM practice guideline for parathyroid scintigraphy 4.0. J Nucl Med Technol 40:111–118. doi:10.2967/jnmt.112.105122 CrossRefPubMed Greenspan BS, Dillehay G, Intenzo C, Lavely WC, O'Doherty M, Palestro CJ, Scheve W, Stabin MG, Sylvestros D, Tulchinsky M (2012) SNM practice guideline for parathyroid scintigraphy 4.0. J Nucl Med Technol 40:111–118. doi:10.​2967/​jnmt.​112.​105122 CrossRefPubMed
24.
go back to reference Braeuning U, Pfannenberg C, Gallwitz B, Teichmann R, Mueller M, Dittmann H, Reimold M, Bares R (2015) 11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism. Nuklearmedizin 54:26–30. doi:10.3413/Nukmed-0686-14-07 CrossRefPubMed Braeuning U, Pfannenberg C, Gallwitz B, Teichmann R, Mueller M, Dittmann H, Reimold M, Bares R (2015) 11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism. Nuklearmedizin 54:26–30. doi:10.​3413/​Nukmed-0686-14-07 CrossRefPubMed
25.
go back to reference Traub-Weidinger T, Mayerhoefer ME, Koperek O, Mitterhauser M, Duan H, Karanikas G, Niederle B, Hoffmann M (2014) 11C-methionine PET/CT imaging of 99mTc-MIBI-SPECT/CT-negative patients with primary hyperparathyroidism and previous neck surgery. J Clin Endocrinol Metab 99:4199–4205. doi:10.1210/jc.2014-1267 CrossRefPubMed Traub-Weidinger T, Mayerhoefer ME, Koperek O, Mitterhauser M, Duan H, Karanikas G, Niederle B, Hoffmann M (2014) 11C-methionine PET/CT imaging of 99mTc-MIBI-SPECT/CT-negative patients with primary hyperparathyroidism and previous neck surgery. J Clin Endocrinol Metab 99:4199–4205. doi:10.​1210/​jc.​2014-1267 CrossRefPubMed
26.
go back to reference Martinez-Rodriguez I, Martínez-Amador N, Arcocha-Torres M, Quirce R, Ortega-Nava F, Ibáñez-Bravo S, Lavado-Pérez C, Bravo-Ferrer Z, Carril JM (2014) Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism. Rev Esp Med Nucl Imagen Mol 33:93–98. doi:10.1016/j.remn.2013.08.002 PubMed Martinez-Rodriguez I, Martínez-Amador N, Arcocha-Torres M, Quirce R, Ortega-Nava F, Ibáñez-Bravo S, Lavado-Pérez C, Bravo-Ferrer Z, Carril JM (2014) Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism. Rev Esp Med Nucl Imagen Mol 33:93–98. doi:10.​1016/​j.​remn.​2013.​08.​002 PubMed
27.
go back to reference Brown SJ, Lee JC, Christie J, Maher R, Sidhu SB, Sywak MS, Delbridge LW (2015) Four-dimensional computed tomography for parathyroid localization: a new imaging modality. ANZ J Surg 85:483–487CrossRefPubMed Brown SJ, Lee JC, Christie J, Maher R, Sidhu SB, Sywak MS, Delbridge LW (2015) Four-dimensional computed tomography for parathyroid localization: a new imaging modality. ANZ J Surg 85:483–487CrossRefPubMed
28.
go back to reference Hinson AM, Lee DR, Hobbs BA, Fitzgerald RT, Bodenner DL, Stack BC Jr (2015) Preoperative 4D CT localization of nonlocalizing parathyroid adenomas by ultrasound and SPECT-CT. Otolaryngol Head Neck Surg 153:775–778CrossRefPubMed Hinson AM, Lee DR, Hobbs BA, Fitzgerald RT, Bodenner DL, Stack BC Jr (2015) Preoperative 4D CT localization of nonlocalizing parathyroid adenomas by ultrasound and SPECT-CT. Otolaryngol Head Neck Surg 153:775–778CrossRefPubMed
29.
go back to reference Kluijfhout WP, Vriens MR, Borel Rinkes IH, Valk GD, de Klerk JM, de Keizer B (2015) 18F-fluorocholine PET-CT for localization of parathyroid adenomas. Ned Tijdschr Geneeskd 159:A8840PubMed Kluijfhout WP, Vriens MR, Borel Rinkes IH, Valk GD, de Klerk JM, de Keizer B (2015) 18F-fluorocholine PET-CT for localization of parathyroid adenomas. Ned Tijdschr Geneeskd 159:A8840PubMed
30.
go back to reference Michaud L, Burgess A, Huchet V, Lefèvre M, Tassart M, Ohnona J, Kerrou K, Balogova S, Talbot JN, Périé S (2014) Is 18F-fluorocholine-poistron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism? J Clin Endocrinol Metab 99:4531–4536CrossRefPubMed Michaud L, Burgess A, Huchet V, Lefèvre M, Tassart M, Ohnona J, Kerrou K, Balogova S, Talbot JN, Périé S (2014) Is 18F-fluorocholine-poistron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism? J Clin Endocrinol Metab 99:4531–4536CrossRefPubMed
Metadata
Title
Localization of parathyroid adenomas using 11C-methionine pet after prior inconclusive imaging
Authors
Milou E Noltes
Annemieke M Coester
Anouk N A van der Horst-Schrivers
Bart Dorgelo
Liesbeth Jansen
Walter Noordzij
Clara Lemstra
Adrienne H Brouwers
Schelto Kruijff
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
Langenbeck's Archives of Surgery / Issue 7/2017
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-017-1549-x

Other articles of this Issue 7/2017

Langenbeck's Archives of Surgery 7/2017 Go to the issue