Skip to main content
Top
Published in: European Journal of Applied Physiology 10/2011

01-10-2011 | Original Article

Are fixed-rate step tests medically safe for assessing physical fitness?

Authors: Dominique Hansen, Nele Jacobs, Steven Bex, Goedele D’Haene, Paul Dendale, Neree Claes

Published in: European Journal of Applied Physiology | Issue 10/2011

Login to get access

Abstract

Maximal oxygen uptake (VO2max) can be predicted by fixed-rate step tests. However, it remains to be analyzed as to what exercise intensities are reached during such tests to address medical safety. In this study, we compared the physiological response to a standardized fixed-rate step test with maximal cardiopulmonary exercise testing (CPET). One hundred and thirteen healthy adults executed a maximal CPET on bike, followed by a standardized fixed-rate step test 1 week later. During these tests, heart rate (HR) and VO2 were monitored continuously. From the maximal CPET, the ventilatory threshold (VT) was calculated. Next, the physiological response between maximal CPET and step testing was compared. The step test intensity was 85 ± 24% CPET VO2max and 88 ± 11% CPET HRmax (VO2max and HRmax were significantly different between CPET and step testing; p < 0.01). In 41% of the subjects, step test exercise intensities >95% CPET VO2max were noted. A greater step testing exercise intensity (%CPET VO2max) was independently related to higher body mass index, and lower body height, exercise capacity (p < 0.05). Standardized fixed-rate step tests elicit vigorous exercise intensities, especially in small, obese, and/or physically deconditioned subjects. Medical supervision might therefore be required during these tests.
Literature
go back to reference Albert CM, Mittleman MA, Chae CU, Lee IM, Hennekens CH, Manson JE (2000) Triggering of sudden death from cardiac causes by vigorous exertion. N Engl J Med 343:1355–1361PubMedCrossRef Albert CM, Mittleman MA, Chae CU, Lee IM, Hennekens CH, Manson JE (2000) Triggering of sudden death from cardiac causes by vigorous exertion. N Engl J Med 343:1355–1361PubMedCrossRef
go back to reference Bartsch P (1999) Platelet activation with exercise and risk of cardiac events. Lancet 354:1747–1748PubMedCrossRef Bartsch P (1999) Platelet activation with exercise and risk of cardiac events. Lancet 354:1747–1748PubMedCrossRef
go back to reference Beaver WL, Wasserman K, Whipp BJ (1986) A new method for detecting anaerobic threshold by gas exchange. J Appl Physiol 60:2020–2027PubMed Beaver WL, Wasserman K, Whipp BJ (1986) A new method for detecting anaerobic threshold by gas exchange. J Appl Physiol 60:2020–2027PubMed
go back to reference Buchfuhrer MJ, Hansen JE, Robinson TE, Sue DY, Wasserman K, Whipp BJ (1983) Optimizing the exercise protocol for cardiopulmonary assessment. J Appl Physiol 55:1558–1564PubMed Buchfuhrer MJ, Hansen JE, Robinson TE, Sue DY, Wasserman K, Whipp BJ (1983) Optimizing the exercise protocol for cardiopulmonary assessment. J Appl Physiol 55:1558–1564PubMed
go back to reference Buckley JP, Sim J, Eston RG, Hession R, Fox R (2004) Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise. Br J Sports Med 38:197–205PubMedCrossRef Buckley JP, Sim J, Eston RG, Hession R, Fox R (2004) Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise. Br J Sports Med 38:197–205PubMedCrossRef
go back to reference Cadroy Y, Pillard F, Sakariassen KS, Thalamas C, Boneu B, Riviere D (2002) Strenuous but not moderate exercise increases the thrombotic tendency in healthy sedentary male volunteers. J Appl Physiol 93:829–833PubMed Cadroy Y, Pillard F, Sakariassen KS, Thalamas C, Boneu B, Riviere D (2002) Strenuous but not moderate exercise increases the thrombotic tendency in healthy sedentary male volunteers. J Appl Physiol 93:829–833PubMed
go back to reference Craig CL, Marshall AL, Sjöström M, Bauman AE, Booth ML, Ainsworth BE, Pratt M, Ekelund U, Yngve A, Sallis JF, Oja P (2003) International physical activity questionnaire: 12-country reliability and validity. Med Sci Sports Exerc 35:1381–1395PubMedCrossRef Craig CL, Marshall AL, Sjöström M, Bauman AE, Booth ML, Ainsworth BE, Pratt M, Ekelund U, Yngve A, Sallis JF, Oja P (2003) International physical activity questionnaire: 12-country reliability and validity. Med Sci Sports Exerc 35:1381–1395PubMedCrossRef
go back to reference Fairbarn MS, Blackie SP, McElvaney NG, Wiggs BR, Paré PD, Pardy RL (1994) Prediction of heart rate and oxygen uptake during incremental and maximal exercise in healthy adults. Chest 105:1365–1369PubMedCrossRef Fairbarn MS, Blackie SP, McElvaney NG, Wiggs BR, Paré PD, Pardy RL (1994) Prediction of heart rate and oxygen uptake during incremental and maximal exercise in healthy adults. Chest 105:1365–1369PubMedCrossRef
go back to reference Fletcher GF, Balady GJ, Amsterdam EA, Chaitman B, Eckel R, Fleg J, Froelicher VF, Leon AS, Piña IL, Rodney R, Simons-Morton DA, Williams MA, Bazzarre T (2001) Exercise standards for testing and training: a statement for healthcare professionals from the American Heart Association. Circulation 104:1694–1740PubMedCrossRef Fletcher GF, Balady GJ, Amsterdam EA, Chaitman B, Eckel R, Fleg J, Froelicher VF, Leon AS, Piña IL, Rodney R, Simons-Morton DA, Williams MA, Bazzarre T (2001) Exercise standards for testing and training: a statement for healthcare professionals from the American Heart Association. Circulation 104:1694–1740PubMedCrossRef
go back to reference Hansen D, Dendale P, Berger J, Meeusen R (2007) Low agreement of ventilatory threshold between training modes in cardiac patients. Eur J Appl Physiol 101:547–554PubMedCrossRef Hansen D, Dendale P, Berger J, Meeusen R (2007) Low agreement of ventilatory threshold between training modes in cardiac patients. Eur J Appl Physiol 101:547–554PubMedCrossRef
go back to reference Hilberg T, Menzel K, Glaser D, Zimmermann S, Gabriel HH (2008) Exercise intensity: platelet function and platelet-leukocyte conjugate formation in untrained subjects. Thromb Res 122:77–84PubMedCrossRef Hilberg T, Menzel K, Glaser D, Zimmermann S, Gabriel HH (2008) Exercise intensity: platelet function and platelet-leukocyte conjugate formation in untrained subjects. Thromb Res 122:77–84PubMedCrossRef
go back to reference Ikarugi H, Shibata M, Shibata S, Ishii H, Taka T, Yamamoto J (2003) High intensity exercise enhances platelet reactivity to shear stress and coagulation during and after exercise. Pathophysiol Haemost Thromb 33:127–133PubMedCrossRef Ikarugi H, Shibata M, Shibata S, Ishii H, Taka T, Yamamoto J (2003) High intensity exercise enhances platelet reactivity to shear stress and coagulation during and after exercise. Pathophysiol Haemost Thromb 33:127–133PubMedCrossRef
go back to reference Jones PW, Wakefield JM, Kontaki E (1987) A simple and portable paced step test for reproducible measurements of ventilation and oxygen consumption during exercise. Thorax 42:136–143PubMedCrossRef Jones PW, Wakefield JM, Kontaki E (1987) A simple and portable paced step test for reproducible measurements of ventilation and oxygen consumption during exercise. Thorax 42:136–143PubMedCrossRef
go back to reference McArdle WD, Katch FI, Katch VL (2010) Individual differences and measurement of energy capacities. Exercise physiology, 7th edn. Lippincott Williams & Wilkins, Philadelphia, pp 225–247 McArdle WD, Katch FI, Katch VL (2010) Individual differences and measurement of energy capacities. Exercise physiology, 7th edn. Lippincott Williams & Wilkins, Philadelphia, pp 225–247
go back to reference Myers J, Arena R, Franklin B, Pina I, Kraus WE, McInnis K, Balady GJ (2009) Recommendations for clinical exercise laboratories. A scientific statement from the American Heart Association. Circulation 119:3144–3161PubMedCrossRef Myers J, Arena R, Franklin B, Pina I, Kraus WE, McInnis K, Balady GJ (2009) Recommendations for clinical exercise laboratories. A scientific statement from the American Heart Association. Circulation 119:3144–3161PubMedCrossRef
go back to reference Noonan V, Dean E (2000) Submaximal exercise testing: clinical application and interpretation. Phys Ther 80:782–807PubMed Noonan V, Dean E (2000) Submaximal exercise testing: clinical application and interpretation. Phys Ther 80:782–807PubMed
go back to reference Olson MS, Williford HN, Blessing DL, Greathouse R (1991) The cardiovascular and metabolic effects of bench stepping exercise in females. Med Sci Sports Exerc 23:1311–1317PubMed Olson MS, Williford HN, Blessing DL, Greathouse R (1991) The cardiovascular and metabolic effects of bench stepping exercise in females. Med Sci Sports Exerc 23:1311–1317PubMed
go back to reference Petrella RJ, Koval JJ, Cunningham DA, Paterson DH (2001) A self-paced step test to predict aerobic fitness in older adults in the primary care clinic. J Am Geriatr Soc 49:632–638PubMedCrossRef Petrella RJ, Koval JJ, Cunningham DA, Paterson DH (2001) A self-paced step test to predict aerobic fitness in older adults in the primary care clinic. J Am Geriatr Soc 49:632–638PubMedCrossRef
go back to reference Petrella RJ, Koval JJ, Cunningham DA, Paterson DH (2003) Can primary care doctors prescribe exercise to improve fitness? The step test exercise prescription (STEP) project. Am J Prev Med 24:316–322PubMedCrossRef Petrella RJ, Koval JJ, Cunningham DA, Paterson DH (2003) Can primary care doctors prescribe exercise to improve fitness? The step test exercise prescription (STEP) project. Am J Prev Med 24:316–322PubMedCrossRef
go back to reference Poole DC, Wilkerson DP, Jones AM (2008) Validity of criteria for establishing maximal O2 uptake during ramp exercise tests. Eur J Appl Physiol 102:403–410PubMedCrossRef Poole DC, Wilkerson DP, Jones AM (2008) Validity of criteria for establishing maximal O2 uptake during ramp exercise tests. Eur J Appl Physiol 102:403–410PubMedCrossRef
go back to reference Renehan AG, Howell A (2005) Preventing cancer, cardiovascular disease, and diabetes. Lancet 365:1449–1451PubMedCrossRef Renehan AG, Howell A (2005) Preventing cancer, cardiovascular disease, and diabetes. Lancet 365:1449–1451PubMedCrossRef
go back to reference Richardson S, Hardman AE (1989) Endurance fitness and blood lactate concentration during stepping exercise in untrained subjects. Br J Sports Med 23:190–193PubMedCrossRef Richardson S, Hardman AE (1989) Endurance fitness and blood lactate concentration during stepping exercise in untrained subjects. Br J Sports Med 23:190–193PubMedCrossRef
go back to reference Siconolfi SF, Garber CE, Lasater TM, Carleton RA (1985) A simple, valid step test for estimating maximal oxygen uptake in epidemiologic studies. Am J Epidemiol 121:382–390PubMed Siconolfi SF, Garber CE, Lasater TM, Carleton RA (1985) A simple, valid step test for estimating maximal oxygen uptake in epidemiologic studies. Am J Epidemiol 121:382–390PubMed
go back to reference Stanforth D, Stanforth PR, Velasquez KS (1993) Aerobic requirement of bench stepping. Int J Sports Med 14:129–133PubMedCrossRef Stanforth D, Stanforth PR, Velasquez KS (1993) Aerobic requirement of bench stepping. Int J Sports Med 14:129–133PubMedCrossRef
go back to reference Thomas SC, Weller IM, Cox MH (1993) Sources of variation in oxygen consumption during a stepping task. Med Sci Sports Exerc 25:139–144PubMedCrossRef Thomas SC, Weller IM, Cox MH (1993) Sources of variation in oxygen consumption during a stepping task. Med Sci Sports Exerc 25:139–144PubMedCrossRef
go back to reference Thompson PD, Franklin BA, Balady GJ, Blair SN, Corrado D, Estes NA 3rd, Fulton JE, Gordon NF, Haskell WL, Link MS, Maron BJ, Mittleman MA, Pelliccia A, Wenger NK, Willich SN, Costa F (2007) Exercise and acute cardiovascular events placing the risks into perspective: a scientific statement from the American Heart Association Council on Nutrition, Physical Activity, and Metabolism and the Council on Clinical Cardiology. Circulation 115:2358–2368PubMedCrossRef Thompson PD, Franklin BA, Balady GJ, Blair SN, Corrado D, Estes NA 3rd, Fulton JE, Gordon NF, Haskell WL, Link MS, Maron BJ, Mittleman MA, Pelliccia A, Wenger NK, Willich SN, Costa F (2007) Exercise and acute cardiovascular events placing the risks into perspective: a scientific statement from the American Heart Association Council on Nutrition, Physical Activity, and Metabolism and the Council on Clinical Cardiology. Circulation 115:2358–2368PubMedCrossRef
Metadata
Title
Are fixed-rate step tests medically safe for assessing physical fitness?
Authors
Dominique Hansen
Nele Jacobs
Steven Bex
Goedele D’Haene
Paul Dendale
Neree Claes
Publication date
01-10-2011
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 10/2011
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-011-1886-3

Other articles of this Issue 10/2011

European Journal of Applied Physiology 10/2011 Go to the issue