Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 10/2022

28-05-2022 | Cataract | Cataract

Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses

Authors: Jung Wan Kim, Youngsub Eom, Wonkyung Park, Jong Suk Song, Ji Won Jeong, Seh Kwang Park, Hyo Myung Kim

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 10/2022

Login to get access

Abstract

Purpose

To compare visual outcomes between two types of mix-and-match implanted trifocal extended-depth-of-focus (EDoF) and trifocal intraocular lenses (IOLs).

Methods

A total of 212 eyes of 106 subjects with mix-and-match implanted FineVision Triumf and FineVision HP IOLs (Triumf–HP group) and 212 eyes of 106 subjects with mix-and-match implanted Zeiss AT LARA and AT LISA IOLs (AT LARA–LISA group) were enrolled in this retrospective case–control study. Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), and binocular distance-corrected defocus curves were measured between 6 and 10 weeks after cataract surgery.

Results

There was no significant difference in UDVA among the four IOLs. UNVA was the best in eyes with the FineVision HP IOL (0.04 ± 0.06 logMAR), followed by eyes with the AT LISA IOL (0.07 ± 0.07 logMAR), the FineVision Triumf IOL (0.09 ± 0.09 logMAR), and the AT LARA IOL (0.11 ± 0.08 logMAR), respectively. The AT LARA–LISA group had better visual acuity than the Triumf–HP group between − 1.00 D and − 1.50 D of defocus, and the Triumf–HP group had better visual acuity than the AT LARA–LISA group between − 3.00 D and − 4.00 D of defocus.

Conclusion

Mix-and-match implantation of trifocal EDoF and trifocal IOLs provided good visual outcomes in far, intermediate, and near distances. The mix-and-match implantation of Triumf–HP IOLs led to better visual outcomes in near vision, while that of the AT LARA–LISA IOLs led to better visual outcomes in intermediate vision.
Literature
4.
go back to reference Chaves MA, Hida WT, Tzeliks PF, Gonçalves MR, Nogueira Fde B, Nakano CT, Motta AF, Araújo AG, Alves MR (2016) Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis ® ZMB00 and AcrySof ® IQ ReSTOR ® Multifocal IOL SN6AD1. Arq Bras Oftalmol 79:171–176. https://doi.org/10.5935/0004-2749.20160050CrossRefPubMed Chaves MA, Hida WT, Tzeliks PF, Gonçalves MR, Nogueira Fde B, Nakano CT, Motta AF, Araújo AG, Alves MR (2016) Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis ® ZMB00 and AcrySof ® IQ ReSTOR ® Multifocal IOL SN6AD1. Arq Bras Oftalmol 79:171–176. https://​doi.​org/​10.​5935/​0004-2749.​20160050CrossRefPubMed
11.
go back to reference Kim JH, Eom Y, Park SY, Choi SY, Hwang HS, Kim JH, Song JS, Kim HM (2020) Rainbow halos occur less following implantation of extended range of vision one-piece intraocular lenses vs diffractive bifocal intraocular lenses. Int J Ophthalmol 13:913–919. https://doi.org/10.18240/ijo.2020.06.09 Kim JH, Eom Y, Park SY, Choi SY, Hwang HS, Kim JH, Song JS, Kim HM (2020) Rainbow halos occur less following implantation of extended range of vision one-piece intraocular lenses vs diffractive bifocal intraocular lenses. Int J Ophthalmol 13:913–919. https://​doi.​org/​10.​18240/​ijo.​2020.​06.​09
18.
19.
go back to reference de Medeiros AL, de Araújo Rolim AG, Motta AFP, Ventura BV, Vilar C, Chaves M, Carricondo PC, Hida WT (2017) Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens. Clin Ophthalmol 11:1911–1916. https://doi.org/10.2147/opth.S145945CrossRefPubMedPubMedCentral de Medeiros AL, de Araújo Rolim AG, Motta AFP, Ventura BV, Vilar C, Chaves M, Carricondo PC, Hida WT (2017) Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens. Clin Ophthalmol 11:1911–1916. https://​doi.​org/​10.​2147/​opth.​S145945CrossRefPubMedPubMedCentral
20.
29.
go back to reference Koga T, Koga T (2015) Factors affecting uncorrected visual acuity following implantation of apodized diffractive intraocular lenses. Nippon Ganka Gakkai Zasshi 119:846–854PubMed Koga T, Koga T (2015) Factors affecting uncorrected visual acuity following implantation of apodized diffractive intraocular lenses. Nippon Ganka Gakkai Zasshi 119:846–854PubMed
Metadata
Title
Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses
Authors
Jung Wan Kim
Youngsub Eom
Wonkyung Park
Jong Suk Song
Ji Won Jeong
Seh Kwang Park
Hyo Myung Kim
Publication date
28-05-2022
Publisher
Springer Berlin Heidelberg
Keyword
Cataract
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 10/2022
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-022-05710-w

Other articles of this Issue 10/2022

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2022 Go to the issue