Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 12/2013

01-12-2013 | Glaucoma

Width of anterior chamber angle determined by OCT, and correlation to refraction and age in a German working population: the MIPH Eye&Health Study

Authors: Urs Vossmerbaeumer, Alexander K. Schuster, Joachim E. Fischer

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 12/2013

Login to get access

Abstract

Background

Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the chamber angle. We performed bilateral spectral-domain OCT measurements in healthy, emmetropic, hyperopic, and myopic subjects to establish correlations between the width of the angle, the refraction, and intraocular pressure of the test persons.

Methods

Out of 4,617 eyes (2,309 subjects), those with refractive errors of < −4 or > +3 diopters were identified by objective refraction measurement (KR-8800 Kerato-Refractometer, Topcon Inc., Japan) and examined using the anterior segment mode of a spectral-domain 3D OCT-2000 (Topcon Inc., Japan). Non-contact tonometry was performed (CT-80, Topcon Inc., Japan). One hundred and eight eyes of 54 emmetropic subjects (± 0.5 dpt) served as reference group. Previous ocular surgery was exclusion criterion in all groups. Width of the chamber angle was determined using semi-automated software tools and statistical analysis of the data (Pearson correlation, ANOVA with post-hoc test and Bonferroni correction, regression analysis) was performed using SPSS software (SPSS 19.0, Chicago, IL, USA).

Results

Six hundred and sixty-eight eyes of 398 persons (292 male, 96 female) were included in the study. Mean hyperopic refraction was +4.24 (+3  to +7.75) dpt, mean myopic refraction was −5.86 (−4 to −11.75) dpt. Valid chamber angle OCT measurements could be obtained from 50 (69.4 %) hyperopic and 400 (71.4 %) myopic eyes meeting the inclusion criteria. The mean width of the chamber angle was determined as 31.8° (range: 13.5 to 45.6, SD 7.49) in the hyperopic group, 40.8° (range: 19.3 to 66.0, SD 8.1) in the myopic group, and 36.3° (range: 21.1 to 51.8, SD 6.8) in the emmetropic reference group. Correlation was highly significant (p > 0.001) between refractive error and the aperture of the chamber angle as measured from OCT. The association of the intraocular pressure and the refraction was also highly significant (p > 0.001) for the three groups.

Conclusion

The spectral-domain OCT yielded measurements that could be used for digital analysis of the chamber angle geometry. Our results highlight the correlation between refraction and aperture of the angle in hyperopia and myopia as determined by the 3D OCT-2000: hyperopia is associated with a narrower chamber angle, myopia with a wider aperture of the angle.
Literature
1.
go back to reference Aung T, Nolan WP, Machin D, Seah SK, Baasanhu J, Khaw PT, Johnson GJ, Foster PJ (2005) Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations. Arch Ophthalmol 123:527–532PubMedCrossRef Aung T, Nolan WP, Machin D, Seah SK, Baasanhu J, Khaw PT, Johnson GJ, Foster PJ (2005) Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations. Arch Ophthalmol 123:527–532PubMedCrossRef
2.
go back to reference Scheie HG (1957) Width and pigmentation of the angle of the anterior chamber; a system of grading by gonioscopy. AMA Arch Ophthalmol 58:510–512PubMedCrossRef Scheie HG (1957) Width and pigmentation of the angle of the anterior chamber; a system of grading by gonioscopy. AMA Arch Ophthalmol 58:510–512PubMedCrossRef
3.
go back to reference Shaffer RN (1962) Stereoscopic manual of gonioscopy. Mosby, St Louis Shaffer RN (1962) Stereoscopic manual of gonioscopy. Mosby, St Louis
4.
go back to reference Spaeth GL (1971) The normal development of the human anterior chamber angle: a new system of descriptive grading. Trans Ophthalmol Soc U K 91:709–739PubMed Spaeth GL (1971) The normal development of the human anterior chamber angle: a new system of descriptive grading. Trans Ophthalmol Soc U K 91:709–739PubMed
5.
go back to reference Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936PubMedCrossRef Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936PubMedCrossRef
6.
go back to reference Tomoyose E, Higa A, Sakai H, Sawaguchi S, Iwase A, Tomidokoro A, Amano S, Araie M (2010) Intraocular pressure and related systemic and ocular biometric factors in a population-based study in Japan: the Kumejima study. Am J Ophthalmol 150:279–286PubMedCrossRef Tomoyose E, Higa A, Sakai H, Sawaguchi S, Iwase A, Tomidokoro A, Amano S, Araie M (2010) Intraocular pressure and related systemic and ocular biometric factors in a population-based study in Japan: the Kumejima study. Am J Ophthalmol 150:279–286PubMedCrossRef
7.
go back to reference Wojciechowski R, Congdon N, Anninger W, Teo Broman A (2003) Age, gender, biometry, refractive error, and the anterior chamber angle among Alaskan Eskimos. Ophthalmology 110:365–375PubMedCentralPubMedCrossRef Wojciechowski R, Congdon N, Anninger W, Teo Broman A (2003) Age, gender, biometry, refractive error, and the anterior chamber angle among Alaskan Eskimos. Ophthalmology 110:365–375PubMedCentralPubMedCrossRef
8.
go back to reference Tarongoy P, Ho CL, Walton DS (2009) Angle-closure glaucoma: the role of the lens in the pathogenesis, prevention, and treatment. Surv Ophthalmol 54:211–225PubMedCrossRef Tarongoy P, Ho CL, Walton DS (2009) Angle-closure glaucoma: the role of the lens in the pathogenesis, prevention, and treatment. Surv Ophthalmol 54:211–225PubMedCrossRef
9.
go back to reference Fontana ST, Brubaker RF (1980) Volume and depth of the anterior chamber in the normal aging human eye. Arch Ophthalmol 98:1803–1808PubMedCrossRef Fontana ST, Brubaker RF (1980) Volume and depth of the anterior chamber in the normal aging human eye. Arch Ophthalmol 98:1803–1808PubMedCrossRef
10.
go back to reference Congdon NG, Foster PJ, Wamsley S, Gutmark J, Nolan W, Seah SK, Johnson GJ, Broman AT (2002) Biometric gonioscopy and the effects of age, race, and sex on the anterior chamber angle. Br J Ophthalmol 86:18–22PubMedCentralPubMedCrossRef Congdon NG, Foster PJ, Wamsley S, Gutmark J, Nolan W, Seah SK, Johnson GJ, Broman AT (2002) Biometric gonioscopy and the effects of age, race, and sex on the anterior chamber angle. Br J Ophthalmol 86:18–22PubMedCentralPubMedCrossRef
11.
go back to reference Oh YG, Minelli S, Spaeth GL, Steinman WC (1994) The anterior chamber angle is different in different racial groups: a gonioscopic study. Eye (Lond) 8(Pt 1):104–108CrossRef Oh YG, Minelli S, Spaeth GL, Steinman WC (1994) The anterior chamber angle is different in different racial groups: a gonioscopic study. Eye (Lond) 8(Pt 1):104–108CrossRef
12.
go back to reference Lowe RF (1970) Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. Br J Ophthalmol 54:161–169PubMedCentralPubMedCrossRef Lowe RF (1970) Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. Br J Ophthalmol 54:161–169PubMedCentralPubMedCrossRef
13.
go back to reference Grewal DS, Brar GS, Jain R, Grewal SP (2011) Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles. Eye (Lond) 25:603–611CrossRef Grewal DS, Brar GS, Jain R, Grewal SP (2011) Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles. Eye (Lond) 25:603–611CrossRef
15.
go back to reference Kempen JH, Mitchell P, Lee KE, Tielsch JM, Broman AT, Taylor HR, Ikram MK, Congdon NG, O’Colmain BJ, Eye Diseases Prevalence Research G (2004) The prevalence of refractive errors among adults in the United States, Western Europe, and Australia. Arch Ophthalmol 122:495–505PubMedCrossRef Kempen JH, Mitchell P, Lee KE, Tielsch JM, Broman AT, Taylor HR, Ikram MK, Congdon NG, O’Colmain BJ, Eye Diseases Prevalence Research G (2004) The prevalence of refractive errors among adults in the United States, Western Europe, and Australia. Arch Ophthalmol 122:495–505PubMedCrossRef
Metadata
Title
Width of anterior chamber angle determined by OCT, and correlation to refraction and age in a German working population: the MIPH Eye&Health Study
Authors
Urs Vossmerbaeumer
Alexander K. Schuster
Joachim E. Fischer
Publication date
01-12-2013
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 12/2013
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-013-2472-7

Other articles of this Issue 12/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 12/2013 Go to the issue