Abstract

Background

Transbronchial lung biopsy (TBBX) is a common respiratory diagnostic procedure performed to investigate several lung diseases. There are different types of forceps used to perform this procedure. The alligator and cupped (oval) forceps are most commonly used ones. To date, there are few studies that have compared the efficacy of these two types of forceps. This study compares the two types of forceps relating to the rate of complications and diagnostic value.

Methods

In this retrospective observational study, 40 patients who underwent TBBX using the alligator forceps were compared to a previous group of 40 patients who underwent the same procedure using the cupped forceps. The two groups were compared with respect to the rate of complications (bleeding and pneumothorax), diagnostic value and size of biopsies.

Results

The rate of complications was higher in patients who underwent TBBX using alligator forceps, in which seven patients (17.5%) had significant bleeding in the group that used alligator forceps versus three patients (7.5%) in cupped forceps group. Pneumothorax developed in three patients, all of whom were in the alligator forceps group. While there was no significant difference in the adequacy and size of the samples, the diagnostic yield was higher in the cupped forceps group.

Conclusions

The results of the study showed that using cupped forceps in performing TBBX had fewer complications (pneumothorax and bleeding) and a higher diagnostic yield in comparison with alligator forceps, but the difference did not reach a statistical significant value.
Literature
2.
go back to reference De Fenoyl O, Capron F, Lebeau B, Rochemaure J (1989) Transbronchial biopsy without fluoroscopy: a five year experience in outpatients. Thorax 44(11):956–959CrossRefPubMedPubMedCentral De Fenoyl O, Capron F, Lebeau B, Rochemaure J (1989) Transbronchial biopsy without fluoroscopy: a five year experience in outpatients. Thorax 44(11):956–959CrossRefPubMedPubMedCentral
3.
4.
go back to reference Pue CA, Pacht ER (1995) Complications of fiberoptic bronchoscopy at a university hospital. Chest 107:430CrossRefPubMed Pue CA, Pacht ER (1995) Complications of fiberoptic bronchoscopy at a university hospital. Chest 107:430CrossRefPubMed
5.
go back to reference Jabbardarjani H, Eslaminejad A, Mohammadtaheri Z, Kiani A, Arab A, Masjedi MR (2010) The effect of cup versus alligator forceps on the results of transbronchial lung biopsy. J Bronchol Interv Pulmonol 17(2):117–121CrossRef Jabbardarjani H, Eslaminejad A, Mohammadtaheri Z, Kiani A, Arab A, Masjedi MR (2010) The effect of cup versus alligator forceps on the results of transbronchial lung biopsy. J Bronchol Interv Pulmonol 17(2):117–121CrossRef
6.
go back to reference Sehgal IS, Bal A, Dhooria S, Agrawal P, Gupta N, Ram B, Aggarwal AN, Behera D, Agarwal R (2016) A prospective randomized controlled trial comparing the efficacy and safety of cup vs alligator forceps for performing transbronchial lung biopsy in patients with sarcoidosis. Chest 149(6):1584–1586CrossRefPubMed Sehgal IS, Bal A, Dhooria S, Agrawal P, Gupta N, Ram B, Aggarwal AN, Behera D, Agarwal R (2016) A prospective randomized controlled trial comparing the efficacy and safety of cup vs alligator forceps for performing transbronchial lung biopsy in patients with sarcoidosis. Chest 149(6):1584–1586CrossRefPubMed
7.
go back to reference Hautmann H, Henke MO, Bitterling H (2010) High diagnostic yield from transbronchial biopsy of solitary pulmonary nodules using low dose CT guidance. Respirology 15:677CrossRefPubMed Hautmann H, Henke MO, Bitterling H (2010) High diagnostic yield from transbronchial biopsy of solitary pulmonary nodules using low dose CT guidance. Respirology 15:677CrossRefPubMed
8.
go back to reference Rittirak W, Sompradeekul S (2007) Diagnostic yield of fluoroscopy-guided transbronchial lung biopsy in non-endobronchial lung lesion. J Med Assoc Thai 90(Suppl 2):68–73PubMed Rittirak W, Sompradeekul S (2007) Diagnostic yield of fluoroscopy-guided transbronchial lung biopsy in non-endobronchial lung lesion. J Med Assoc Thai 90(Suppl 2):68–73PubMed
9.
go back to reference Curley FJ, Johal JS, Burke ME et al (1998) Transbronchial lung biopsy: can specimen quality be predicted at the time of biopsy. Chest 113:1037–1041CrossRefPubMed Curley FJ, Johal JS, Burke ME et al (1998) Transbronchial lung biopsy: can specimen quality be predicted at the time of biopsy. Chest 113:1037–1041CrossRefPubMed
Metadata
Title
The Effect of Using Different Types of Forceps in the Efficacy of Transbronchial Lung Biopsy
Authors
Abdulrahman Almadani
Melissa N. Y. Ping
Anu Deenadayalu
Jean Saunders
Aidan O’Brien
Publication date
01-02-2019
Publisher
Springer US
Published in
Lung / Issue 1/2019
Print ISSN: 0341-2040
Electronic ISSN: 1432-1750
DOI
https://doi.org/10.1007/s00408-018-0179-6

Other articles of this Issue 1/2019

Lung 1/2019 Go to the issue