Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 3/2017

01-03-2017 | Miscellaneous

Validation study of WatchPat 200 for diagnosis of OSA in an Asian cohort

Authors: Yijin Jereme Gan, Louis Lim, Yaw Khian Chong

Published in: European Archives of Oto-Rhino-Laryngology | Issue 3/2017

Login to get access

Abstract

To validate a wrist-worn portable device (WatchPat 200) to diagnose OSA in an Asian cohort. To evaluate its cost-effectiveness. Twenty patients with suspected OSA were recruited and had simultaneous polysomnography (PSG) and WatchPAT assessments concurrently within the hospital’s sleep laboratory. The study population consisted of 18 male and 2 female patients, whose mean age was 39 (±16) years, mean BMI was 27.2 (±5.5) kg/m2, mean Epworth Sleepiness score was 8.55 (±4.8). The correlation between the AHI was assessed using Spearman’s correlation coefficient and agreement was tested via the Bland Altman plot. Sensitivities and specificities were then applied to the various AHI groups. Spearman’s coefficient was 0.94, which suggested that a very strong correlation between the AHI recorded by the WatchPat and the PSG. Bland–Altman plot showed good agreement with the AHI mean difference of about 4.23 with a slight tendency to overscore the AHI at the mild range of OSA and underscore the range at the severe end of OSA. The WatchPat showed 100% sensitivity when compared to PSG for mild OSA and is thus a good screening test for the undiagnosed general population. Furthermore, it also showed 100% specificity when compared to PSG for severe OSA suggesting that it is a good diagnostic test for people with a high suspicion of OSA. This facilitates a timelier diagnosis and a more economical approach with potential cost savings of up to $900 per patient.
Literature
1.
go back to reference Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S (1993) The occurrence of sleep-disordered breathing among middle aged adults. N Engl J Med 328:1230–1235CrossRefPubMed Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S (1993) The occurrence of sleep-disordered breathing among middle aged adults. N Engl J Med 328:1230–1235CrossRefPubMed
2.
go back to reference Sharma SK, Agrawal S, Damodaran D et al (2011) CPAP for the metabolic syndrome in patients with obstructive sleep apnea. N Engl J Med 365:2277–2286CrossRefPubMed Sharma SK, Agrawal S, Damodaran D et al (2011) CPAP for the metabolic syndrome in patients with obstructive sleep apnea. N Engl J Med 365:2277–2286CrossRefPubMed
3.
go back to reference Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnoea. J Clin Sleep Med 3:737–747PubMedCentral Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnoea. J Clin Sleep Med 3:737–747PubMedCentral
4.
go back to reference Bar A, Pillar G, Dvir I et al (2003) Evaluation of a portable device based on peripheral arterial tone for unatended home sleep studies. Chest 123:695–703CrossRefPubMed Bar A, Pillar G, Dvir I et al (2003) Evaluation of a portable device based on peripheral arterial tone for unatended home sleep studies. Chest 123:695–703CrossRefPubMed
5.
go back to reference Johns MW (1991) A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep 14:540–545CrossRefPubMed Johns MW (1991) A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep 14:540–545CrossRefPubMed
6.
go back to reference Berry R, Budhiraja R, Gottlieb DJ et al (2012) Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. J Clin Sleep Med 88:597–619 Berry R, Budhiraja R, Gottlieb DJ et al (2012) Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. J Clin Sleep Med 88:597–619
7.
go back to reference Ayas NT, Pittman S, MacDonald M, White DP (2003) Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 4:435–442CrossRefPubMed Ayas NT, Pittman S, MacDonald M, White DP (2003) Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 4:435–442CrossRefPubMed
8.
go back to reference Li W, Wang R, Huang D, Liu X, Jin W, Yang S (2013) Assessment of a portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea. Eur Arch Otorhinolaryngol 270:3099–4015CrossRef Li W, Wang R, Huang D, Liu X, Jin W, Yang S (2013) Assessment of a portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea. Eur Arch Otorhinolaryngol 270:3099–4015CrossRef
9.
go back to reference Pittman SD, Ayas NT, Macdonald MM et al (2004) using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnoea. Sleep 27:923–933PubMedPubMedCentral Pittman SD, Ayas NT, Macdonald MM et al (2004) using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnoea. Sleep 27:923–933PubMedPubMedCentral
10.
go back to reference Chan YH (2003) Biostatistics 104: correlational Analysis. Singapore Med J 44:614–619PubMed Chan YH (2003) Biostatistics 104: correlational Analysis. Singapore Med J 44:614–619PubMed
11.
go back to reference Pillar G, Bar A, Betito M et al (2003) Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 4:207–212CrossRefPubMed Pillar G, Bar A, Betito M et al (2003) Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 4:207–212CrossRefPubMed
12.
go back to reference Schnall RP, Shlitner A, Sheffy J, Kedar R, Lavie P (1999) Periodic, profound peripheral vasoconstriction—a new marker of obstructive sleep apnea. Sleep 22:939–946PubMed Schnall RP, Shlitner A, Sheffy J, Kedar R, Lavie P (1999) Periodic, profound peripheral vasoconstriction—a new marker of obstructive sleep apnea. Sleep 22:939–946PubMed
13.
go back to reference O’Donnell CP, Allan L, Atkinson P, Schwartz AR (2002) The effect of upper airway obstruction and arousal on peripheral arterial tonometry in obstructive sleep apnea. Am J Respir Crit Care Med 166:965–971CrossRefPubMed O’Donnell CP, Allan L, Atkinson P, Schwartz AR (2002) The effect of upper airway obstruction and arousal on peripheral arterial tonometry in obstructive sleep apnea. Am J Respir Crit Care Med 166:965–971CrossRefPubMed
14.
go back to reference Silva E, Balieiro FO, Xavier SD et al (2013) Comparative analysis of diagnostic methods in obstructive sleep apnea syndrome: polysomnography and use Watch Pat 200. Otolaryngol Head Neck Surg 149:267–270CrossRef Silva E, Balieiro FO, Xavier SD et al (2013) Comparative analysis of diagnostic methods in obstructive sleep apnea syndrome: polysomnography and use Watch Pat 200. Otolaryngol Head Neck Surg 149:267–270CrossRef
Metadata
Title
Validation study of WatchPat 200 for diagnosis of OSA in an Asian cohort
Authors
Yijin Jereme Gan
Louis Lim
Yaw Khian Chong
Publication date
01-03-2017
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 3/2017
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-016-4351-4

Other articles of this Issue 3/2017

European Archives of Oto-Rhino-Laryngology 3/2017 Go to the issue