Published in: European Archives of Oto-Rhino-Laryngology 7/2016

Open Access 01-07-2016 | Otology

Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability

Authors: Rik C. Nelissen, Christine A. den Besten, Hubert T. Faber, Catharina A. J. Dun, Emmanuel A. M. Mylanus, Myrthe K. S. Hol

Published in: European Archives of Oto-Rhino-Laryngology | Issue 7/2016

Login to get access

Abstract

The objective of this study was to ascertain the long-term safety of loading osseointegrated implants for bone conduction hearing 3 weeks post-surgery. Thirty consecutive adult patients were implanted with the Baha BI300 (Cochlear Bone Anchored Solutions) in our tertiary referral center. Implants were loaded with the sound processor 3 weeks post-surgery. Follow-up examinations were performed at 10 days; 3, 4, 6, 8, and 12 weeks; 6 months; and 1, 2, and 3 years after implant surgery. At each follow-up visit, implant stability quotient (ISQ) values were recorded by means of resonance frequency analysis, and soft tissue status was evaluated according to Holgers’ classification. ISQ trends, implant survival, and soft tissue reactions were compared to a population of 52 patients with the same type of implants loaded from 6 weeks post-surgery as part of another study. Subjective benefit was measured by means of the Glasgow Benefit Inventory (GBI). After an initial dip in ISQ at 10 days after implantation, a gradually increasing trend in ISQ was found until 6 months in both populations, after which ISQ values remained above baseline values. Implant survival was 97 % in the study population and 96 % in the comparison population. Clinically relevant soft tissue reactions were found in 0.9 % (study population) and 1.7 % (comparison population) of all visits. Patients reported subjective benefit; the mean GBI score was 22.8. In conclusion, loading these implants at 3 weeks post-surgery is safe based on the current study, as long-term results show high ISQ values and good implant survival and tolerability.
Literature
1.
go back to reference Tjellström A, Lindström J, Hallén O et al (1981) Osseointegrated titanium implants in the temporal bone. A clinical study on bone-anchored hearing aids. Am J Otol 2:304–310PubMed Tjellström A, Lindström J, Hallén O et al (1981) Osseointegrated titanium implants in the temporal bone. A clinical study on bone-anchored hearing aids. Am J Otol 2:304–310PubMed
2.
go back to reference Snik AFM, Mylanus EAM, Proops DW et al (2005) Consensus statements on the BAHA system: where do we stand at present? Ann Otol Rhinol Laryngol 114(195):1–12 Snik AFM, Mylanus EAM, Proops DW et al (2005) Consensus statements on the BAHA system: where do we stand at present? Ann Otol Rhinol Laryngol 114(195):1–12
3.
go back to reference Tjellström A, Lindström J, Hallén O et al (1983) Direct bone anchorage of external hearing aids. J Biomed Eng 5:59–63CrossRefPubMed Tjellström A, Lindström J, Hallén O et al (1983) Direct bone anchorage of external hearing aids. J Biomed Eng 5:59–63CrossRefPubMed
4.
go back to reference Tjellström A, Granström G (1995) One-stage procedure to establish osseointegration: a zero to five years follow-up report. J Laryngol Otol 109:593–598CrossRefPubMed Tjellström A, Granström G (1995) One-stage procedure to establish osseointegration: a zero to five years follow-up report. J Laryngol Otol 109:593–598CrossRefPubMed
11.
12.
go back to reference Nelissen RC, Stalfors J, de Wolf MJF et al (2014) Long-term stability, survival, and tolerability of a novel osseointegrated implant for bone conduction hearing: 3-year data from a multicenter, randomized, controlled, clinical investigation. Otol Neurotol 35:1486–1491. doi:10.1097/MAO.0000000000000533 CrossRefPubMed Nelissen RC, Stalfors J, de Wolf MJF et al (2014) Long-term stability, survival, and tolerability of a novel osseointegrated implant for bone conduction hearing: 3-year data from a multicenter, randomized, controlled, clinical investigation. Otol Neurotol 35:1486–1491. doi:10.​1097/​MAO.​0000000000000533​ CrossRefPubMed
13.
go back to reference Robinson K, Gatehouse S, Browning GG (1996) Measuring patient benefit from otorhinolaryngological surgery and therapy. Ann Otol Rhinol Laryngol 105:415–422CrossRefPubMed Robinson K, Gatehouse S, Browning GG (1996) Measuring patient benefit from otorhinolaryngological surgery and therapy. Ann Otol Rhinol Laryngol 105:415–422CrossRefPubMed
16.
go back to reference Holgers KM, Tjellström A, Bjursten LM, Erlandsson BE (1988) Soft tissue reactions around percutaneous implants: a clinical study of soft tissue conditions around skin-penetrating titanium implants for bone-anchored hearing aids. Am J Otol 9:56–59PubMed Holgers KM, Tjellström A, Bjursten LM, Erlandsson BE (1988) Soft tissue reactions around percutaneous implants: a clinical study of soft tissue conditions around skin-penetrating titanium implants for bone-anchored hearing aids. Am J Otol 9:56–59PubMed
23.
Metadata
Title
Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
Authors
Rik C. Nelissen
Christine A. den Besten
Hubert T. Faber
Catharina A. J. Dun
Emmanuel A. M. Mylanus
Myrthe K. S. Hol
Publication date
01-07-2016
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 7/2016
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-015-3746-y

Other articles of this Issue 7/2016

European Archives of Oto-Rhino-Laryngology 7/2016 Go to the issue