Published in: European Archives of Oto-Rhino-Laryngology 4/2014

01-04-2014 | Otology

Presentation of floating mass transducer and Vibroplasty Couplers on CT and Cone Beam CT

Authors: Robert Mlynski, Thi Dao Nguyen, Stefan K. Plontke, Sabrina Kösling

Published in: European Archives of Oto-Rhino-Laryngology | Issue 4/2014

Login to get access

Abstract

Various titanium coupling elements, Vibroplasty Couplers, maintaining the attachment of the Floating Mass Transducer (FMT) of the active middle ear implant Vibrant Soundbridge (VSB) to the round window, the stapes suprastructure or the stapes footplate are in use to optimally transfer energy from the FMT to the inner ear fluids. In certain cases it is of interest to radiologically verify the correct position of the FMT coupler assembly. The imaging appearance of FMT connected to these couplers, however, is not well known. The aim of this study was to present the radiological appearance of correctly positioned Vibroplasty Couplers together with the FMT using two different imaging techniques. Vibroplasty Couplers were attached to the FMT of a Vibrant Soundbridge and implanted in formalin fixed human temporal bones. Five FMT coupler assemblies were implanted in different positions: conventionally to the incus, a Bell-Coupler, a CliP-Coupler, a Round Window-Coupler and an Oval Window-Coupler. High spatial resolution imaging with Multi-Detector CT (MDCT) and Cone Beam CT (CBCT) was performed in each specimen. Images were blind evaluated by two radiologists on a visual basis. Middle ear details, identification of FMT and coupler, position of FMT coupler assembly and artefacts were assessed. CBCT showed a better spatial resolution and a higher visual image quality than MDCT, but there was no significant advantage over MDCT in delineating the structures or the temporal bone of the FMT Coupler assemblies. The FMT with its coupler element could be clearly identified in the two imaging techniques. The correct positioning of the FMT and all types of couplers could be demonstrated. Both methods, MDCT and CBCT, are appropriate methods for postoperative localization of FMT in combination with Vibroplasty Couplers and for verifying their correct position. If CBCT is available, this method is recommended due to the better spatial resolution and less metal artifacts.
Literature
1.
go back to reference Barillari M, Cerini R, Carner M, Cacciatori C, Spagnolli F, Cardobi N, Mandala M, Colletti L, Colletti V, Pozzi Mucelli R (2012) Congenital aural atresia treated with floating mass transducer on the round window: 5 years of imaging experience. Radiol Med 117:488–499PubMedCrossRef Barillari M, Cerini R, Carner M, Cacciatori C, Spagnolli F, Cardobi N, Mandala M, Colletti L, Colletti V, Pozzi Mucelli R (2012) Congenital aural atresia treated with floating mass transducer on the round window: 5 years of imaging experience. Radiol Med 117:488–499PubMedCrossRef
2.
go back to reference Baumgartner WD, Boheim K, Hagen R, Muller J, Lenarz T, Reiss S, Schlogel M, Mlynski R, Mojallal H, Colletti V, Opie J (2010) The vibrant soundbridge for conductive and mixed hearing losses: European multicenter study results. Adv Otorhinolaryngol 69:38–50PubMed Baumgartner WD, Boheim K, Hagen R, Muller J, Lenarz T, Reiss S, Schlogel M, Mlynski R, Mojallal H, Colletti V, Opie J (2010) The vibrant soundbridge for conductive and mixed hearing losses: European multicenter study results. Adv Otorhinolaryngol 69:38–50PubMed
3.
go back to reference Beleites T, Neudert M, Beutner D, Huttenbrink KB, Zahnert T (2011) Experience with vibroplasty couplers at the stapes head and footplate. Otol Neurotol 32:1468–1472PubMedCrossRef Beleites T, Neudert M, Beutner D, Huttenbrink KB, Zahnert T (2011) Experience with vibroplasty couplers at the stapes head and footplate. Otol Neurotol 32:1468–1472PubMedCrossRef
4.
go back to reference Beutner D, Luers JC, Huttenbrink KB (2008) Cartilage ‘shoe’: a new technique for stabilisation of titanium total ossicular replacement prosthesis at centre of stapes footplate. J Laryngol Otol 122:682–686PubMedCrossRef Beutner D, Luers JC, Huttenbrink KB (2008) Cartilage ‘shoe’: a new technique for stabilisation of titanium total ossicular replacement prosthesis at centre of stapes footplate. J Laryngol Otol 122:682–686PubMedCrossRef
5.
go back to reference Boheim K, Mlynski R, Lenarz T, Schlogel M, Hagen R (2012) Round window vibroplasty: Long-term results. Acta Otolaryngol 132:1042–1048PubMedCrossRef Boheim K, Mlynski R, Lenarz T, Schlogel M, Hagen R (2012) Round window vibroplasty: Long-term results. Acta Otolaryngol 132:1042–1048PubMedCrossRef
6.
go back to reference Bozzato A, Struffert T, Hertel V, Iro H, Hornung J (2010) Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses. Eur Radiol 20:566–571PubMedCrossRef Bozzato A, Struffert T, Hertel V, Iro H, Hornung J (2010) Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses. Eur Radiol 20:566–571PubMedCrossRef
7.
go back to reference Huber AM, Mlynski R, Muller J, Dillier N, Holzmann D, Wolframm MD, Hagen R (2012) A new vibroplasty coupling technique as a treatment for conductive and mixed hearing losses: a report of 4 cases. Otol Neurotol 33:613–617PubMedCrossRef Huber AM, Mlynski R, Muller J, Dillier N, Holzmann D, Wolframm MD, Hagen R (2012) A new vibroplasty coupling technique as a treatment for conductive and mixed hearing losses: a report of 4 cases. Otol Neurotol 33:613–617PubMedCrossRef
8.
go back to reference Huttenbrink KB, Beutner D, Zahnert T (2010) Clinical results with an active middle ear implant in the oval window. Adv Otorhinolaryngol 69:27–31PubMed Huttenbrink KB, Beutner D, Zahnert T (2010) Clinical results with an active middle ear implant in the oval window. Adv Otorhinolaryngol 69:27–31PubMed
9.
go back to reference Huttenbrink KB, Zahnert T, Bornitz M, Beutner D (2008) TORP-vibroplasty: a new alternative for the chronically disabled middle ear. Otol Neurotol 29:965–971PubMedCrossRef Huttenbrink KB, Zahnert T, Bornitz M, Beutner D (2008) TORP-vibroplasty: a new alternative for the chronically disabled middle ear. Otol Neurotol 29:965–971PubMedCrossRef
10.
go back to reference Jager L, Bonell H, Liebl M, Srivastav S, Arbusow V, Hempel M, Reiser M (2005) CT of the normal temporal bone: comparison of multi- and single-detector row CT. Radiology 235:133–141PubMedCrossRef Jager L, Bonell H, Liebl M, Srivastav S, Arbusow V, Hempel M, Reiser M (2005) CT of the normal temporal bone: comparison of multi- and single-detector row CT. Radiology 235:133–141PubMedCrossRef
11.
go back to reference Knoergen M, Brandt S, Koesling S (2012) Comparison of dosage and spatial resolution of digital X-Ray devices with 3D-capability in head and neck imaging. RöFo 184:1153–1160 Knoergen M, Brandt S, Koesling S (2012) Comparison of dosage and spatial resolution of digital X-Ray devices with 3D-capability in head and neck imaging. RöFo 184:1153–1160
12.
13.
go back to reference Kurzweg T, Dalchow CV, Bremke M, Majdani O, Kureck I, Knecht R, Werner JA, Teymoortash A (2010) The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens. Ear Hear 31:413–419PubMedCrossRef Kurzweg T, Dalchow CV, Bremke M, Majdani O, Kureck I, Knecht R, Werner JA, Teymoortash A (2010) The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens. Ear Hear 31:413–419PubMedCrossRef
14.
go back to reference Vibrant Med-El (2012) Fürstenweg 77, A-6020 Innsbruck Austria Vibrant Med-El (2012) Fürstenweg 77, A-6020 Innsbruck Austria
15.
go back to reference Mlynski R, Mueller J, Hagen R (2010) Surgical approaches to position the Vibrant Soundbridge in conductive and mixed hearing loss. Op Tech Otolaryngol 21:272–277CrossRef Mlynski R, Mueller J, Hagen R (2010) Surgical approaches to position the Vibrant Soundbridge in conductive and mixed hearing loss. Op Tech Otolaryngol 21:272–277CrossRef
16.
go back to reference Penninger RT, Tavassolie TS, Carey JP (2011) Cone-beam volumetric tomography for applications in the temporal bone. Otol Neurotol 32:453–460PubMedCrossRef Penninger RT, Tavassolie TS, Carey JP (2011) Cone-beam volumetric tomography for applications in the temporal bone. Otol Neurotol 32:453–460PubMedCrossRef
17.
go back to reference Schwab B, Salcher RB, Maier H, Kontorinis G (2012) Oval window membrane vibroplasty for direct acoustic cochlear stimulation: treating severe mixed hearing loss in challenging middle ears. Otol Neurotol 33:804–809PubMedCrossRef Schwab B, Salcher RB, Maier H, Kontorinis G (2012) Oval window membrane vibroplasty for direct acoustic cochlear stimulation: treating severe mixed hearing loss in challenging middle ears. Otol Neurotol 33:804–809PubMedCrossRef
18.
go back to reference Snik AF, Mylanus EA, Cremers CW, Dillier N, Fisch U, Gnadeberg D, Lenarz T, Mazolli M, Babighian G, Uziel AS, Cooper HR, O’Connor AF, Fraysse B, Charachon R, Shehata-Dieler WE (2001) Multicenter audiometric results with the Vibrant Soundbridge, a semi-implantable hearing device for sensorineural hearing impairment. Otolaryngol Clin North Am 34:373–388PubMedCrossRef Snik AF, Mylanus EA, Cremers CW, Dillier N, Fisch U, Gnadeberg D, Lenarz T, Mazolli M, Babighian G, Uziel AS, Cooper HR, O’Connor AF, Fraysse B, Charachon R, Shehata-Dieler WE (2001) Multicenter audiometric results with the Vibrant Soundbridge, a semi-implantable hearing device for sensorineural hearing impairment. Otolaryngol Clin North Am 34:373–388PubMedCrossRef
19.
go back to reference Struffert T, Hertel V, Kyriakou Y, Krause J, Engelhorn T, Schick B, Iro H, Hornung J, Doerfler A (2010) Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose. Acta Otolaryngol 130:443–452PubMedCrossRef Struffert T, Hertel V, Kyriakou Y, Krause J, Engelhorn T, Schick B, Iro H, Hornung J, Doerfler A (2010) Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose. Acta Otolaryngol 130:443–452PubMedCrossRef
20.
go back to reference Teymoortash A, Hamzei S, Murthum T, Eivazi B, Kureck I, Werner JA (2011) Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study. Surg Radiol Anat 33:123–128PubMedCrossRef Teymoortash A, Hamzei S, Murthum T, Eivazi B, Kureck I, Werner JA (2011) Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study. Surg Radiol Anat 33:123–128PubMedCrossRef
21.
go back to reference Zaoui K, Kromeier J, Neudert M, Boedeker CC, Zahnert T, Laszig R, Offergeld C (2012) Flat panel CT following stapes prosthesis insertion: an experimental and clinical study. Eur Radiol 22:837–844PubMedCrossRef Zaoui K, Kromeier J, Neudert M, Boedeker CC, Zahnert T, Laszig R, Offergeld C (2012) Flat panel CT following stapes prosthesis insertion: an experimental and clinical study. Eur Radiol 22:837–844PubMedCrossRef
Metadata
Title
Presentation of floating mass transducer and Vibroplasty Couplers on CT and Cone Beam CT
Authors
Robert Mlynski
Thi Dao Nguyen
Stefan K. Plontke
Sabrina Kösling
Publication date
01-04-2014
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 4/2014
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-013-2457-5

Other articles of this Issue 4/2014

European Archives of Oto-Rhino-Laryngology 4/2014 Go to the issue