01-03-2010 | Computed Tomography

Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses

Authors: Alessandro Bozzato, Tobias Struffert, Victoria Hertel, Heinrich Iro, Joachim Hornung

Published in: European Radiology | Issue 3/2010

Login to get access

Abstract

Purpose

Severe cochleovestibulopathy is a complication after stapes plasty and CT may be needed to assess intravestibular intrusion depth of the stapes piston. The accuracy of modern CT systems in this task has not been established.

Methods

Stapes plasty was performed on six cadaver ears, and Soft CliP titanium pistons were inserted. Specimens were then examined using three different CT systems: single source 64-row, dual source 64-row and flat-panel computed tomography (FD-CT). Piston length, width and intravestibular intrusion were measured by four independent observers. Temporal bone dissection was then performed and vestibular piston intrusion measured microscopically.

Results

Piston dimensions were overestimated by all observers and CT systems. Intravestibular penetration as assessed by CT was consistently greater than the value found on cadaveric anatomical dissection. On average, the CT measurement of width was 0.176 mm (44%) greater, length 0.125 mm (6.25%) greater and intrusion 0.333 mm (39.2%) greater than the anatomical measurements. FD-CT showed better image quality and partly less bias in several measurements, but penetration depth was still variably overestimated.

Conclusion

CT measurement consistently overestimated intravestibular piston dimensions and vestibular intrusion. Modern temporal bone imaging systems are not yet able to depict the stapes piston position with a sufficient degree of accuracy.
Literature
1.
go back to reference Hausler R (2007) General history of stapedectomy. Adv Otorhinolaryngol 65:1–5PubMed Hausler R (2007) General history of stapedectomy. Adv Otorhinolaryngol 65:1–5PubMed
2.
go back to reference Kosling S, Brandt S, Bloching M, Bohme S (2004) Indications of HR-CT in the early postoperative phase of stapedotomy. Rofo 176:1122–1126PubMed Kosling S, Brandt S, Bloching M, Bohme S (2004) Indications of HR-CT in the early postoperative phase of stapedotomy. Rofo 176:1122–1126PubMed
3.
go back to reference Oberascher G, Grobovschek M (1987) High-resolution computed tomography in stapes surgery. HNO 35:255–261PubMed Oberascher G, Grobovschek M (1987) High-resolution computed tomography in stapes surgery. HNO 35:255–261PubMed
4.
go back to reference Oberascher G, Grobovschek M (1988) Identification of middle ear implants in high-resolution computerized tomography. Laryngol Rhinol Otol (Stuttg) 67:17–22CrossRef Oberascher G, Grobovschek M (1988) Identification of middle ear implants in high-resolution computerized tomography. Laryngol Rhinol Otol (Stuttg) 67:17–22CrossRef
5.
go back to reference Woldag K, Meister EF, Kosling S (1995) Diagnosis in persistent vertigo after stapes surgery. Laryngorhinootologie 74:403–407CrossRefPubMed Woldag K, Meister EF, Kosling S (1995) Diagnosis in persistent vertigo after stapes surgery. Laryngorhinootologie 74:403–407CrossRefPubMed
6.
go back to reference Albera R, Canale A, Lacilla M, Cavalot AL, Ferrero V (2004) Delayed vertigo after stapes surgery. Laryngoscope 114:860–862CrossRefPubMed Albera R, Canale A, Lacilla M, Cavalot AL, Ferrero V (2004) Delayed vertigo after stapes surgery. Laryngoscope 114:860–862CrossRefPubMed
7.
go back to reference Backous DD, Minor LB, Aboujaoude ES, Nager GT (1999) Relationship of the utriculus and sacculus to the stapes footplate: anatomic implications for sound-and/or pressure-induced otolith activation. Ann Otol Rhinol Laryngol 108:548–553PubMed Backous DD, Minor LB, Aboujaoude ES, Nager GT (1999) Relationship of the utriculus and sacculus to the stapes footplate: anatomic implications for sound-and/or pressure-induced otolith activation. Ann Otol Rhinol Laryngol 108:548–553PubMed
8.
go back to reference Pauw BK, Pollak AM, Fisch U (1991) Utricle, saccule, and cochlear duct in relation to stapedotomy. A histologic human temporal bone study. Ann Otol Rhinol Laryngol 100:966–970PubMed Pauw BK, Pollak AM, Fisch U (1991) Utricle, saccule, and cochlear duct in relation to stapedotomy. A histologic human temporal bone study. Ann Otol Rhinol Laryngol 100:966–970PubMed
9.
go back to reference Hahn Y, Diaz R, Hartman J, Bobinski M, Brodie H (2009) Assessing stapes piston position using computed tomography: a cadaveric study. Otol Neurotol 30(2):223–230CrossRefPubMed Hahn Y, Diaz R, Hartman J, Bobinski M, Brodie H (2009) Assessing stapes piston position using computed tomography: a cadaveric study. Otol Neurotol 30(2):223–230CrossRefPubMed
10.
go back to reference Kosling S, Woldag K, Meister EF, Reschke I, Heywang-Kobrunner SH (1995) Value of computed tomography in patients with persistent vertigo after stapes surgery. Invest Radiol, 30:712–715CrossRef Kosling S, Woldag K, Meister EF, Reschke I, Heywang-Kobrunner SH (1995) Value of computed tomography in patients with persistent vertigo after stapes surgery. Invest Radiol, 30:712–715CrossRef
11.
go back to reference Roosli C, Hoffmann A, Treumann T, Linder TE (2008) Significance of computed tomography evaluation before revision stapes surgery. HNO 56:895–900CrossRefPubMed Roosli C, Hoffmann A, Treumann T, Linder TE (2008) Significance of computed tomography evaluation before revision stapes surgery. HNO 56:895–900CrossRefPubMed
12.
go back to reference Warren FM, Riggs S, Wiggins RH 3rd (2008) Computed tomographic imaging of stapes implants. Otol Neurotol 29:586–592CrossRefPubMed Warren FM, Riggs S, Wiggins RH 3rd (2008) Computed tomographic imaging of stapes implants. Otol Neurotol 29:586–592CrossRefPubMed
13.
go back to reference Swartz JD, Lansman AK, Berger AS et al (1986) Stapes prosthesis: evaluation with CT. Radiology, 158:179–182 Swartz JD, Lansman AK, Berger AS et al (1986) Stapes prosthesis: evaluation with CT. Radiology, 158:179–182
14.
go back to reference Pickuth D, Brandt S, Berghaus A, Spielmann RP, Heywang-Kobrunner SH (2000) Vertigo after stapes surgery: the role of high resolution CT. Br J Radiol 73:1021–1023PubMed Pickuth D, Brandt S, Berghaus A, Spielmann RP, Heywang-Kobrunner SH (2000) Vertigo after stapes surgery: the role of high resolution CT. Br J Radiol 73:1021–1023PubMed
15.
go back to reference Henrot P, Iochum S, Batch T, Coffinet L, Blum A, Roland J (2005) Current multiplanar imaging of the stapes. AJNR Am J Neuroradiol 26:2128–2133PubMed Henrot P, Iochum S, Batch T, Coffinet L, Blum A, Roland J (2005) Current multiplanar imaging of the stapes. AJNR Am J Neuroradiol 26:2128–2133PubMed
16.
go back to reference Chakeres DW (1984) Clinical significance of partial volume averaging of the temporal bone. AJNR Am J Neuroradiol 5:297–302PubMed Chakeres DW (1984) Clinical significance of partial volume averaging of the temporal bone. AJNR Am J Neuroradiol 5:297–302PubMed
Metadata
Title
Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses
Authors
Alessandro Bozzato
Tobias Struffert
Victoria Hertel
Heinrich Iro
Joachim Hornung
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
European Radiology / Issue 3/2010
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1582-4

Other articles of this Issue 3/2010

European Radiology 3/2010 Go to the issue