Skip to main content
Top
Published in: Archives of Gynecology and Obstetrics 5/2017

Open Access 01-05-2017 | Maternal-Fetal Medicine

Double-balloon catheter for induction of labour in women with a previous cesarean section, could it be the best choice?

Authors: Carlos De Bonrostro Torralba, Eva Lucía Tejero Cabrejas, Sabina Marti Gamboa, María Lapresta Moros, Jose Manuel Campillos Maza, Sergio Castán Mateo

Published in: Archives of Gynecology and Obstetrics | Issue 5/2017

Login to get access

Abstract

Introduction

We analysed the efficacy and safety of double-balloon catheter for cervical ripening in women with a previous cesarean section and which were the most important variables associated with an increased risk of repeated cesarean delivery.

Materials and methods

We designed an observational retrospective study of 418 women with unfavourable cervices (Bishop Score <5), a prior cesarean delivery, and induction of labour with a double-balloon catheter. Baseline maternal data and perinatal outcomes were recorded for a descriptive, bivariate, and multivariate analysis. A p value <0.05 was considered statistically significant.

Results

Most women improved their initial Bishop Score (89.5%) although only a 20.8% of them went into spontaneous active labour. Finally, 51.4% of the women achieved a vaginal delivery. Five cases of intrapartum uterine rupture (1.2%) occurred. After multivariate analysis, main risk factors for repeated cesarean section were dystocia in the previous pregnancy (OR 1.744; CI 95% 1.066–2.846), the absence of previous vaginal delivery (OR 2.590; CI 95% 1.066–6.290), suspected fetal macrosomia (OR 2.410; CI 95% 0.959–6.054), and duration of oxytocin induction period (OR 1.005; CI 95% 1.004–1.006). The area under the curve was 0.789 (p < 0.001).

Conclusions

Double-balloon catheter seems to be safe and effective for cervical ripening in women with a previous cesarean delivery and unfavourable cervix. In our study, most women could have a vaginal delivery in spite of their risk factors for cesarean delivery. A multivariate model based on some clinical variables has moderate predictive value for intrapartum cesarean section.
Literature
1.
go back to reference Vogel JP, Gulmezoglu AMM, Hofmeyr GJ, Temmerman M (2014) Global perspectives on elective induction of labor. Clin Obstet Gynecol 57:331–342CrossRefPubMed Vogel JP, Gulmezoglu AMM, Hofmeyr GJ, Temmerman M (2014) Global perspectives on elective induction of labor. Clin Obstet Gynecol 57:331–342CrossRefPubMed
2.
3.
go back to reference Chen W, Xue J, Peprah MK, Wen SW, Walker M, Gao Y, Tang Y (2016) A systematic review and network meta-analysis comparing the use of Foley catheters, misoprostol, and dinoprostone for cervical ripening in the induction of labour. BJOG 123:346–354 Chen W, Xue J, Peprah MK, Wen SW, Walker M, Gao Y, Tang Y (2016) A systematic review and network meta-analysis comparing the use of Foley catheters, misoprostol, and dinoprostone for cervical ripening in the induction of labour. BJOG 123:346–354
5.
go back to reference Rossi AC, Prefumo F (2015) Pregnancy outcomes of induced labor in women with previous cesarean section: a systematic review and meta-analysis. Arch Gynecol Obstet 291(2):273–280CrossRefPubMed Rossi AC, Prefumo F (2015) Pregnancy outcomes of induced labor in women with previous cesarean section: a systematic review and meta-analysis. Arch Gynecol Obstet 291(2):273–280CrossRefPubMed
6.
go back to reference Kwee A, Bots ML, Visser GH, Bruinse HW (2007) Obstetric management and outcome of pregnancy in women with a history of caesarean section in the Netherlands. Eur J Obstet Gynecol Reprod Biol 132(2):171–176CrossRefPubMed Kwee A, Bots ML, Visser GH, Bruinse HW (2007) Obstetric management and outcome of pregnancy in women with a history of caesarean section in the Netherlands. Eur J Obstet Gynecol Reprod Biol 132(2):171–176CrossRefPubMed
7.
go back to reference Jozwiak M, Bloemenkamp KW, Kelly AJ, Mol BW, Irion O, Boulvain M (2012) Mechanical methods for induction of labour. Cochrane Database Syst Rev 14(3):CD001233 Jozwiak M, Bloemenkamp KW, Kelly AJ, Mol BW, Irion O, Boulvain M (2012) Mechanical methods for induction of labour. Cochrane Database Syst Rev 14(3):CD001233
9.
go back to reference Rossard L, Arlicot C, Blasco H, Potin J, Denis C, Mercier D et al (2013) Cervical ripening with balloon catheter for scared uterus: a three-year retrospective study. J Gynecol Obstet Biol Reprod 42:480–487CrossRef Rossard L, Arlicot C, Blasco H, Potin J, Denis C, Mercier D et al (2013) Cervical ripening with balloon catheter for scared uterus: a three-year retrospective study. J Gynecol Obstet Biol Reprod 42:480–487CrossRef
10.
go back to reference Al-Zirqi I, Stray-Pedersen B, Forsén L, Vangen S (2010) Uterine rupture after previous caesarean section. BJOG 117:809–820CrossRefPubMed Al-Zirqi I, Stray-Pedersen B, Forsén L, Vangen S (2010) Uterine rupture after previous caesarean section. BJOG 117:809–820CrossRefPubMed
11.
go back to reference Boyon C, Monsarrat N, Clouqueur E, Deruelle P (2014) Cervical ripening: is there an advantage for a double-balloon device in labor induction? Gynecol Obstet Fertil 42:674–680CrossRefPubMed Boyon C, Monsarrat N, Clouqueur E, Deruelle P (2014) Cervical ripening: is there an advantage for a double-balloon device in labor induction? Gynecol Obstet Fertil 42:674–680CrossRefPubMed
13.
go back to reference Khotaba S, Volfson M, Tarazova L, Odeh M, Barenboym R, Fait V et al (2001) Induction of labor in women with previous cesarean section using the double balloon device. Acta Obstet Gynecol Scand 80:1041–1042CrossRefPubMed Khotaba S, Volfson M, Tarazova L, Odeh M, Barenboym R, Fait V et al (2001) Induction of labor in women with previous cesarean section using the double balloon device. Acta Obstet Gynecol Scand 80:1041–1042CrossRefPubMed
14.
go back to reference Miller TD, Davis G (2005) Use of the Atad catheter for the induction of labour in women who have had a previous Cesarean section—a case series. Aust N Z J Obstet Gynaecol 45(4):325–327CrossRefPubMed Miller TD, Davis G (2005) Use of the Atad catheter for the induction of labour in women who have had a previous Cesarean section—a case series. Aust N Z J Obstet Gynaecol 45(4):325–327CrossRefPubMed
15.
go back to reference Ferradas E, Alvarado I, Gabilondo M, Diez-Itza I, García-Adánez J (2013) Double balloon device compared to oxytocin for induction of labour after previous cesarean section. Open J Obstet Gynecol 3:212–216CrossRef Ferradas E, Alvarado I, Gabilondo M, Diez-Itza I, García-Adánez J (2013) Double balloon device compared to oxytocin for induction of labour after previous cesarean section. Open J Obstet Gynecol 3:212–216CrossRef
16.
go back to reference Ebeid E, Nassif N (2013) Induction of labor using double balloon cervical device in women with previous cesarean section: experience and review. Open J Obstet Gynecol 3:301–305CrossRef Ebeid E, Nassif N (2013) Induction of labor using double balloon cervical device in women with previous cesarean section: experience and review. Open J Obstet Gynecol 3:301–305CrossRef
17.
go back to reference Cheuk QK, Lo TK, Lee CP, Yeung AP (2015) Double balloon catheter for induction of labour in Chinese women with previous cesarean section: one-year experience and literature review. Hong Kong Med J 21(3):243–250PubMed Cheuk QK, Lo TK, Lee CP, Yeung AP (2015) Double balloon catheter for induction of labour in Chinese women with previous cesarean section: one-year experience and literature review. Hong Kong Med J 21(3):243–250PubMed
18.
go back to reference Agnew G, Turner MJ (2009) Vaginal prostaglandin gel to induce labour in women with one previous caesarean section. J Obstet Gynaecol 29:209–211CrossRefPubMed Agnew G, Turner MJ (2009) Vaginal prostaglandin gel to induce labour in women with one previous caesarean section. J Obstet Gynaecol 29:209–211CrossRefPubMed
19.
go back to reference Kehl, Sven, Weiss, Christel, Rath, Werner (2016) Balloon catheters for induction of labor at term after previous cesarean section: a systematic review. Eur J Obstet Gynecol Reprod Biol 204:44–50CrossRefPubMed Kehl, Sven, Weiss, Christel, Rath, Werner (2016) Balloon catheters for induction of labor at term after previous cesarean section: a systematic review. Eur J Obstet Gynecol Reprod Biol 204:44–50CrossRefPubMed
20.
go back to reference Jozwiak M, van de Lest HA, Burger NB, Dijksterhuis MG, De Leeuw JW (2014) Cervical ripening with Foley catheter for induction of labor after cesarean section: a cohort study. Acta Obstet Gynecol Scand 93(3):296–301CrossRefPubMed Jozwiak M, van de Lest HA, Burger NB, Dijksterhuis MG, De Leeuw JW (2014) Cervical ripening with Foley catheter for induction of labor after cesarean section: a cohort study. Acta Obstet Gynecol Scand 93(3):296–301CrossRefPubMed
23.
go back to reference Melamed N, Yariv O, Hiersch L, Wiznitzer A, Meizner I, Yogev Y (2013) Labor induction with prostaglandin E2: characteristics of response and prediction of failure. J Matern Fetal Neonatal Med 26:132–136CrossRefPubMed Melamed N, Yariv O, Hiersch L, Wiznitzer A, Meizner I, Yogev Y (2013) Labor induction with prostaglandin E2: characteristics of response and prediction of failure. J Matern Fetal Neonatal Med 26:132–136CrossRefPubMed
24.
go back to reference Kolkman DG, Verhoeven CJ, Brinkhorst SJ, van der Post JA, Pajkrt E, Opmeer BC et al. (2013) The Bishop score as a predictor of labor induction success: a systematic review. Am J Perinatol 30:625–630CrossRefPubMed Kolkman DG, Verhoeven CJ, Brinkhorst SJ, van der Post JA, Pajkrt E, Opmeer BC et al. (2013) The Bishop score as a predictor of labor induction success: a systematic review. Am J Perinatol 30:625–630CrossRefPubMed
25.
go back to reference Cheung, Chun Wai, Leung, Tak Yeung, Sahota, Daljit Singh, Chan, Oi Ka, Chan, Lin Wai, Fung, Tak Yuen, Lau, Tze Kin (2010) Outcome of induction of labour using maternal characteristics, ultrasound assessment and biochemical state of the cervix. J Matern Fetal Neonat Med 23(12):1406–1412CrossRef Cheung, Chun Wai, Leung, Tak Yeung, Sahota, Daljit Singh, Chan, Oi Ka, Chan, Lin Wai, Fung, Tak Yuen, Lau, Tze Kin (2010) Outcome of induction of labour using maternal characteristics, ultrasound assessment and biochemical state of the cervix. J Matern Fetal Neonat Med 23(12):1406–1412CrossRef
26.
go back to reference Ezebialu IU, Eke AC, Eleje GU, Nwachukwu CE (2015) Methods for assessing pre-induction cervical ripening. Cochrane Database Syst Rev 6:1–31 Ezebialu IU, Eke AC, Eleje GU, Nwachukwu CE (2015) Methods for assessing pre-induction cervical ripening. Cochrane Database Syst Rev 6:1–31
27.
go back to reference Grobman WA, Lai Y, Landon MB, Spong CY, Leveno KJ, Rouse DJ, Varner MW et al. (2007) Development of a nomogram for prediction of vaginal birth after cesarean delivery. Obstet Gynecol 109:806–812CrossRefPubMed Grobman WA, Lai Y, Landon MB, Spong CY, Leveno KJ, Rouse DJ, Varner MW et al. (2007) Development of a nomogram for prediction of vaginal birth after cesarean delivery. Obstet Gynecol 109:806–812CrossRefPubMed
Metadata
Title
Double-balloon catheter for induction of labour in women with a previous cesarean section, could it be the best choice?
Authors
Carlos De Bonrostro Torralba
Eva Lucía Tejero Cabrejas
Sabina Marti Gamboa
María Lapresta Moros
Jose Manuel Campillos Maza
Sergio Castán Mateo
Publication date
01-05-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Gynecology and Obstetrics / Issue 5/2017
Print ISSN: 0932-0067
Electronic ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-017-4343-7

Other articles of this Issue 5/2017

Archives of Gynecology and Obstetrics 5/2017 Go to the issue