Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 8/2017

01-08-2017 | Orthopaedic Surgery

Intraoperative adjustment of alignment under valgus stress reduces outliers in patients undergoing medial opening-wedge high tibial osteotomy

Authors: Man Soo Kim, Jong Min Son, In Jun Koh, Ji Hoon Bahk, Yong In

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 8/2017

Login to get access

Abstract

Introduction

A considerable percentage of outliers with under- or over-correction continue to be reported despite precise preoperative planning and cautious intraoperative correction of lower limb alignment in medial opening-wedge high tibial osteotomy (MOWHTO). The purpose of this study was to determine whether our novel technique for the intraoperative adjustment of alignment under valgus stress reduces the number of outliers in patients undergoing MOWHTO compared to the conventional technique, which corrects alignment according to the cable method only.

Materials and methods

One hundred seventeen consecutive knees were enrolled in this case–control study. The first 52 knees (51 patients) were corrected in accordance with preoperative plans using the Dugdale method with modification with an intraoperative cable (group 1). In the other 65 knees (60 patients), the angle was corrected using the Dugdale method and limb alignment was adjusted using the intraoperative cable technique by applying valgus stress to the knee joint (group 2). The postoperative weight bearing line ratios and mechanical axis of the lower limb were compared at postoperative one year. Each knee was evaluated according to the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score preoperatively and at postoperative one year.

Results

A significant reduction in the number of outliers was seen in group 2 compared to group 1 (group 1 = 48.1%, group 2 = 9.2%, p < 0.001). Nineteen of 52 knees (36.5%) were under-corrected in group 1, whereas 6 of 65 knees (9.2%) were under-corrected in group 2 (p < 0.001). Six of 52 knees (11.6%) were over-corrected in group 1, whereas 0 of 65 knees (0.0%) were over-corrected in group 2 (p = 0.005). At one -year after operation, group 2 showed significantly lower WOMAC score than group 1 (p = 0.014).

Conclusions

Intraoperative adjustment of alignment under valgus stress significantly reduced the number of outliers compared to a technique that corrected alignment using the cable method in patients undergoing MOWHTO.

Level of evidence

Level III, retrospective comparative study.
Literature
1.
go back to reference Hankemeier S, Mommsen P, Krettek C, Jagodzinski M, Brand J, Meyer C, Meller R (2010) Accuracy of high tibial osteotomy: comparison between open- and closed-wedge technique. Knee Surg Sports Traumatol Arthrosc 18:1328–1333. doi:10.1007/s00167-009-1020-9 CrossRefPubMed Hankemeier S, Mommsen P, Krettek C, Jagodzinski M, Brand J, Meyer C, Meller R (2010) Accuracy of high tibial osteotomy: comparison between open- and closed-wedge technique. Knee Surg Sports Traumatol Arthrosc 18:1328–1333. doi:10.​1007/​s00167-009-1020-9 CrossRefPubMed
2.
6.
go back to reference Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195CrossRefPubMed Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195CrossRefPubMed
7.
go back to reference Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Jt Surg Am 85-a:469–474CrossRef Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Jt Surg Am 85-a:469–474CrossRef
9.
go back to reference Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 274:248–264 Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 274:248–264
10.
go back to reference El-Azab HM, Morgenstern M, Ahrens P, Schuster T, Imhoff AB, Lorenz SG (2011) Limb alignment after open-wedge high tibial osteotomy and its effect on the clinical outcome. Orthopedics 34:e622–e628. doi:10.3928/01477447-20110826-02 PubMed El-Azab HM, Morgenstern M, Ahrens P, Schuster T, Imhoff AB, Lorenz SG (2011) Limb alignment after open-wedge high tibial osteotomy and its effect on the clinical outcome. Orthopedics 34:e622–e628. doi:10.​3928/​01477447-20110826-02 PubMed
12.
go back to reference Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227 Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227
13.
go back to reference Kendoff D, Board TN, Citak M, Gardner MJ, Hankemeier S, Ostermeier S, Krettek C, Hufner T (2008) Navigated lower limb axis measurements: influence of mechanical weight-bearing simulation. J Orthop Res 26:553–561. doi:10.1002/jor.20510 CrossRefPubMed Kendoff D, Board TN, Citak M, Gardner MJ, Hankemeier S, Ostermeier S, Krettek C, Hufner T (2008) Navigated lower limb axis measurements: influence of mechanical weight-bearing simulation. J Orthop Res 26:553–561. doi:10.​1002/​jor.​20510 CrossRefPubMed
14.
go back to reference Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 29(Suppl 3):C29–C39CrossRefPubMed Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 29(Suppl 3):C29–C39CrossRefPubMed
15.
go back to reference Lee DH, Han SB, Oh KJ, Lee JS, Kwon JH, Kim JI, Patnaik S, Shetty GM, Nha KW (2014) The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy. Knee 21:451–455. doi:10.1016/j.knee.2012.09.003 CrossRefPubMed Lee DH, Han SB, Oh KJ, Lee JS, Kwon JH, Kim JI, Patnaik S, Shetty GM, Nha KW (2014) The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy. Knee 21:451–455. doi:10.​1016/​j.​knee.​2012.​09.​003 CrossRefPubMed
16.
go back to reference Lee YS, Kim MG, Byun HW, Kim SB, Kim JG (2015) Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 23:846–851CrossRefPubMed Lee YS, Kim MG, Byun HW, Kim SB, Kim JG (2015) Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 23:846–851CrossRefPubMed
17.
go back to reference Liodakis E, Kenawey M, Liodaki E, Mommsen P, Krettek C, Hankemeier S (2010) The axis-board: an alternative to the cable technique for intraoperative assessment of lower limb alignment. Technol Health Care 18:165–171. doi:10.3233/thc-2010-0579 PubMed Liodakis E, Kenawey M, Liodaki E, Mommsen P, Krettek C, Hankemeier S (2010) The axis-board: an alternative to the cable technique for intraoperative assessment of lower limb alignment. Technol Health Care 18:165–171. doi:10.​3233/​thc-2010-0579 PubMed
18.
go back to reference Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426CrossRefPubMed Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426CrossRefPubMed
19.
go back to reference Kyung BS, Kim JG, Jang KM, Chang M, Moon YW, Ahn JH, Wang JH (2013) Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs. Am J Sports Med 41:2368–2374. doi:10.1177/0363546513498062 CrossRefPubMed Kyung BS, Kim JG, Jang KM, Chang M, Moon YW, Ahn JH, Wang JH (2013) Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs. Am J Sports Med 41:2368–2374. doi:10.​1177/​0363546513498062​ CrossRefPubMed
20.
go back to reference Gaasbeek RD, Nicolaas L, Rijnberg WJ, van Loon CJ, van Kampen A (2010) Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy. A one-year randomised controlled study. Int Orthop 34:201–207. doi:10.1007/s00264-009-0861-7 CrossRefPubMed Gaasbeek RD, Nicolaas L, Rijnberg WJ, van Loon CJ, van Kampen A (2010) Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy. A one-year randomised controlled study. Int Orthop 34:201–207. doi:10.​1007/​s00264-009-0861-7 CrossRefPubMed
24.
go back to reference Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
26.
go back to reference Lee DH, Park SC, Park HJ, Han SB (2015) Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3682-9 Lee DH, Park SC, Park HJ, Han SB (2015) Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3682-9
27.
go back to reference Ogata K, Yoshii I, Kawamura H, Miura H, Arizono T, Sugioka Y (1991) Standing radiographs cannot determine the correction in high tibial osteotomy. J Bone Jt Surg Br 73:927–931 Ogata K, Yoshii I, Kawamura H, Miura H, Arizono T, Sugioka Y (1991) Standing radiographs cannot determine the correction in high tibial osteotomy. J Bone Jt Surg Br 73:927–931
28.
go back to reference Na YG, Eom SH, Kim SJ, Chang MJ, Kim TK (2016) The use of navigation in medial opening wedge high tibial osteotomy can improve tibial slope maintenance and reduce radiation exposure. Int Orthop 40:499–507. doi:10.1007/s00264-015-2880-x CrossRefPubMed Na YG, Eom SH, Kim SJ, Chang MJ, Kim TK (2016) The use of navigation in medial opening wedge high tibial osteotomy can improve tibial slope maintenance and reduce radiation exposure. Int Orthop 40:499–507. doi:10.​1007/​s00264-015-2880-x CrossRefPubMed
29.
go back to reference Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed
30.
go back to reference Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 28:85–94. doi:10.1016/j.arthro.2011.06.034 CrossRefPubMed Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 28:85–94. doi:10.​1016/​j.​arthro.​2011.​06.​034 CrossRefPubMed
31.
go back to reference Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25:379–386PubMed Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25:379–386PubMed
33.
go back to reference Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 246:250–259 Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 246:250–259
35.
go back to reference Insall JN, Joseph DM, Msika C (1984) High tibial osteotomy for varus gonarthrosis. A long-term follow-up study. J Bone Jt Surg Am 66:1040–1048CrossRef Insall JN, Joseph DM, Msika C (1984) High tibial osteotomy for varus gonarthrosis. A long-term follow-up study. J Bone Jt Surg Am 66:1040–1048CrossRef
36.
go back to reference Kim SJ, Koh YG, Chun YM, Kim YC, Park YS, Sung CH (2009) Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: a 1-year retrospective, comparative study. Knee Surg Sports Traumatol Arthrosc 17:128–134. doi:10.1007/s00167-008-0630-y CrossRefPubMed Kim SJ, Koh YG, Chun YM, Kim YC, Park YS, Sung CH (2009) Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: a 1-year retrospective, comparative study. Knee Surg Sports Traumatol Arthrosc 17:128–134. doi:10.​1007/​s00167-008-0630-y CrossRefPubMed
37.
go back to reference Lutzner J, Gross AF, Gunther KP, Kirschner S (2010) Precision of navigated and conventional open-wedge high tibial osteotomy in a cadaver study. Eur J Med Res 15:117–120CrossRefPubMedPubMedCentral Lutzner J, Gross AF, Gunther KP, Kirschner S (2010) Precision of navigated and conventional open-wedge high tibial osteotomy in a cadaver study. Eur J Med Res 15:117–120CrossRefPubMedPubMedCentral
39.
go back to reference Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2012) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593. doi:10.1007/s00167-011-1616-8 CrossRefPubMed Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2012) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593. doi:10.​1007/​s00167-011-1616-8 CrossRefPubMed
40.
go back to reference Iorio R, Pagnottelli M, Vadala A, Giannetti S, Di Sette P, Papandrea P, Conteduca F, Ferretti A (2013) Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 21:113–119. doi:10.1007/s00167-011-1785-5 CrossRefPubMed Iorio R, Pagnottelli M, Vadala A, Giannetti S, Di Sette P, Papandrea P, Conteduca F, Ferretti A (2013) Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 21:113–119. doi:10.​1007/​s00167-011-1785-5 CrossRefPubMed
41.
go back to reference Maurer F, Wassmer G (2006) High tibial osteotomy: does navigation improve results? Orthopedics 29:S130–S132PubMed Maurer F, Wassmer G (2006) High tibial osteotomy: does navigation improve results? Orthopedics 29:S130–S132PubMed
42.
go back to reference Gebhard F, Krettek C, Hufner T, Grutzner PA, Stockle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P (2011) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131:297–302. doi:10.1007/s00402-010-1145-9 CrossRefPubMed Gebhard F, Krettek C, Hufner T, Grutzner PA, Stockle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P (2011) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131:297–302. doi:10.​1007/​s00402-010-1145-9 CrossRefPubMed
43.
44.
go back to reference Dexel J, Fritzsche H, Beyer F, Harman MK, Lutzner J (2015) Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3730-5 Dexel J, Fritzsche H, Beyer F, Harman MK, Lutzner J (2015) Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3730-5
47.
go back to reference van Raaij TM, Brouwer RW, de Vlieger R, Reijman M, Verhaar JA (2008) Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique. Acta Orthop 79:508–514. doi:10.1080/17453670710015508 CrossRefPubMed van Raaij TM, Brouwer RW, de Vlieger R, Reijman M, Verhaar JA (2008) Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique. Acta Orthop 79:508–514. doi:10.​1080/​1745367071001550​8 CrossRefPubMed
48.
go back to reference Nakamura R, Komatsu N, Murao T, Okamoto Y, Nakamura S, Fujita K, Nishimura H, Katsuki Y (2015) The validity of the classification for lateral hinge fractures in open wedge high tibial osteotomy. Bone Jt J 97-b:1226–1231. doi:10.1302/0301-620x.97b9.34949 CrossRef Nakamura R, Komatsu N, Murao T, Okamoto Y, Nakamura S, Fujita K, Nishimura H, Katsuki Y (2015) The validity of the classification for lateral hinge fractures in open wedge high tibial osteotomy. Bone Jt J 97-b:1226–1231. doi:10.​1302/​0301-620x.​97b9.​34949 CrossRef
49.
50.
go back to reference Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (Position HTO plate) without bone substitute. Arthroscopy 27:644–652. doi:10.1016/j.arthro.2011.01.008 CrossRefPubMed Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (Position HTO plate) without bone substitute. Arthroscopy 27:644–652. doi:10.​1016/​j.​arthro.​2011.​01.​008 CrossRefPubMed
Metadata
Title
Intraoperative adjustment of alignment under valgus stress reduces outliers in patients undergoing medial opening-wedge high tibial osteotomy
Authors
Man Soo Kim
Jong Min Son
In Jun Koh
Ji Hoon Bahk
Yong In
Publication date
01-08-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2017
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2729-4

Other articles of this Issue 8/2017

Archives of Orthopaedic and Trauma Surgery 8/2017 Go to the issue