Abstract

Purpose

The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy.

Methods

A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip–knee–ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient.

Results

Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p < 0.001). Using the real-size paper template method, the correction angle and height of the osteotomy gap were 11.5° ± 3.4° and 10.9 ± 3.8 mm, respectively. Using the picture-archiving and communications system-photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p < 0.001).

Conclusions

Use of the picture-archiving and communications system-photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.

Level of evidence

III.
Literature
1.
go back to reference Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2011) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593CrossRefPubMed Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2011) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593CrossRefPubMed
2.
go back to reference Amis AA (2012) Biomechanics of high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:197–205CrossRefPubMed Amis AA (2012) Biomechanics of high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:197–205CrossRefPubMed
3.
go back to reference Asada S, Akagi M, Mori S, Matsushita T, Hashimoto K, Hamanishi C (2012) Increase in posterior tibial slope would result in correction loss in frontal plane after medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 20:571–578CrossRefPubMed Asada S, Akagi M, Mori S, Matsushita T, Hashimoto K, Hamanishi C (2012) Increase in posterior tibial slope would result in correction loss in frontal plane after medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 20:571–578CrossRefPubMed
4.
go back to reference Bae DK, Yoon KH, Song SJ, Shin MC, Noh JH (2008) Navigation versus Radiographic Measurements in the Open-Wedge High Tibial Osteotomy using Computer Assisted Surgery (CAS). J Korean Orthop Assoc 43:301–307CrossRef Bae DK, Yoon KH, Song SJ, Shin MC, Noh JH (2008) Navigation versus Radiographic Measurements in the Open-Wedge High Tibial Osteotomy using Computer Assisted Surgery (CAS). J Korean Orthop Assoc 43:301–307CrossRef
5.
go back to reference Brouwer RW, Bierma-Zeinstra SM, van Koeveringe AJ, Verhaar JA (2005) Patellar height and the inclination of the tibial plateau after high tibial osteotomy. The open versus the closed-wedge technique. J Bone Joint Surg Br 87:1227–1232CrossRefPubMed Brouwer RW, Bierma-Zeinstra SM, van Koeveringe AJ, Verhaar JA (2005) Patellar height and the inclination of the tibial plateau after high tibial osteotomy. The open versus the closed-wedge technique. J Bone Joint Surg Br 87:1227–1232CrossRefPubMed
6.
go back to reference Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 248–264 Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 248–264
7.
go back to reference El-Azab H, Halawa A, Anetzberger H, Imhoff AB, Hinterwimmer S (2008) The effect of closed- and open-wedge high tibial osteotomy on tibial slope: a retrospective radiological review of 120 cases. J Bone Joint Surg Br 90:1193–1197CrossRefPubMed El-Azab H, Halawa A, Anetzberger H, Imhoff AB, Hinterwimmer S (2008) The effect of closed- and open-wedge high tibial osteotomy on tibial slope: a retrospective radiological review of 120 cases. J Bone Joint Surg Br 90:1193–1197CrossRefPubMed
8.
go back to reference Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
9.
go back to reference Gebhard F, Krettek C, Hufner T, Grutzner PA, Stockle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P (2010) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131:297–302CrossRefPubMedCentralPubMed Gebhard F, Krettek C, Hufner T, Grutzner PA, Stockle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P (2010) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131:297–302CrossRefPubMedCentralPubMed
10.
go back to reference Hankemeier S, Hufner T, Wang G, Kendoff D, Zeichen J, Zheng G, Krettek C (2006) Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc 14:917–921CrossRefPubMed Hankemeier S, Hufner T, Wang G, Kendoff D, Zeichen J, Zheng G, Krettek C (2006) Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc 14:917–921CrossRefPubMed
11.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354PubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354PubMed
12.
go back to reference Lee DH, Han SB, Oh KJ, Lee JS, Kwon JH, Kim JI, Patnaik S, Shetty GM, Nha KW (2012) The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy. Knee. doi:10.1016/j.knee.2012.09.003 Lee DH, Han SB, Oh KJ, Lee JS, Kwon JH, Kim JI, Patnaik S, Shetty GM, Nha KW (2012) The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy. Knee. doi:10.​1016/​j.​knee.​2012.​09.​003
13.
go back to reference Lee DH, Nha KW, Park SJ, Han SB (2012) Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy. Arthroscopy 28:1842–1850CrossRefPubMed Lee DH, Nha KW, Park SJ, Han SB (2012) Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy. Arthroscopy 28:1842–1850CrossRefPubMed
14.
15.
go back to reference Marx RG, Grimm P, Lillemoe KA, Robertson CM, Ayeni OR, Lyman S, Bogner EA, Pavlov H (2011) Reliability of lower extremity alignment measurement using radiographs and PACS. Knee Surg Sports Traumatol Arthrosc 19:1693–1698CrossRefPubMed Marx RG, Grimm P, Lillemoe KA, Robertson CM, Ayeni OR, Lyman S, Bogner EA, Pavlov H (2011) Reliability of lower extremity alignment measurement using radiographs and PACS. Knee Surg Sports Traumatol Arthrosc 19:1693–1698CrossRefPubMed
16.
go back to reference Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 246:250–259PubMed Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 246:250–259PubMed
17.
go back to reference Pape D, Rupp S (2007) Preoperative Planning for High Tibial Osteotomies. Oper Tech Orthop 17:2–11CrossRef Pape D, Rupp S (2007) Preoperative Planning for High Tibial Osteotomies. Oper Tech Orthop 17:2–11CrossRef
18.
go back to reference Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute. Arthroscopy 27:644–652CrossRefPubMed Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute. Arthroscopy 27:644–652CrossRefPubMed
19.
go back to reference Schroter S, Gunzel J, Freude T, Ateschrang A, Stockle U, Albrecht D (2012) Precision in the planning of open wedge HTO. Z Orthop Unfall 150:368–373PubMed Schroter S, Gunzel J, Freude T, Ateschrang A, Stockle U, Albrecht D (2012) Precision in the planning of open wedge HTO. Z Orthop Unfall 150:368–373PubMed
20.
go back to reference Schroter S, Ihle C, Mueller J, Lobenhoffer P, Stockle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196CrossRefPubMed Schroter S, Ihle C, Mueller J, Lobenhoffer P, Stockle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196CrossRefPubMed
21.
go back to reference Sled EA, Sheehy LM, Felson DT, Costigan PA, Lam M, Cooke TD (2011) Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program. Rheumatol Int 31:71–77CrossRefPubMedCentralPubMed Sled EA, Sheehy LM, Felson DT, Costigan PA, Lam M, Cooke TD (2011) Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program. Rheumatol Int 31:71–77CrossRefPubMedCentralPubMed
22.
go back to reference Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed
23.
go back to reference Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–B62CrossRefPubMed Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–B62CrossRefPubMed
Metadata
Title
Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy
Authors
Yong Seuk Lee
Min Gyu Kim
Hae Won Byun
Sang Bum Kim
Jin Goo Kim
Publication date
01-03-2015
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 3/2015
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2700-z

Other articles of this Issue 3/2015

Knee Surgery, Sports Traumatology, Arthroscopy 3/2015 Go to the issue