Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 3/2017

01-03-2017 | Knee Arthroplasty

Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation

Authors: Kazumasa Yamamura, Yukihide Minoda, Shigekazu Mizokawa, Yoichi Ohta, Ryo Sugama, Suguru Nakamura, Hideki Ueyama, Hiroaki Nakamura

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 3/2017

Login to get access

Abstract

Introduction

This study was designed to evaluate the true accuracy of patient specific instrumentation (PSI) for total knee arthroplasty (TKA) using a new 3D measurement method.

Materials and methods

Consecutive 21 patients (30 knees) who underwent TKA using computed tomography (CT)-based PSI were retrospectively evaluated. Mean patient age was 69.2 years (62 to 77). The postoperative three-dimensional (3D) CT image were superimposed onto the preoperative 3D CT plan and measured the absolute difference in the prosthetic alignment using six parameters: coronal, sagittal, and axial alignment of the femoral and tibial prostheses. Cases in which the difference in the prosthetic alignment was greater than 3° were considered outliers.

Results

For the femoral prosthesis, mean absolute differences between the preoperative 3D CT plan and postoperative 3D CT image were not significantly different and the rates of outliers were 10.0, 33.3, 23.3% in the coronal, sagittal, and axial planes. For the tibial prosthesis, mean absolute differences were significantly larger in the axial plane than in the coronal and sagittal planes (p < 0.001) and the rates of outliers were 23.3, 36.7, 63.3% in the coronal, sagittal, and axial planes. The rates of outliers for the axial alignment of tibial prosthesis were significantly higher than for the other five planes (p = 0.006).

Conclusions

The rotation of the tibial prosthesis with CT-based PSI was less accurate in the axial plane than in the other five planes.
Literature
3.
go back to reference Liu HX, Shang P, Ying XZ, Zhang Y (2015) Shorter survival rate in varus-aligned knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3781-7 Liu HX, Shang P, Ying XZ, Zhang Y (2015) Shorter survival rate in varus-aligned knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3781-7
4.
go back to reference Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G (2012) Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients. J Bone Joint Surg Am 94(11):1023–1029. doi:10.2106/JBJS.K.00927 CrossRefPubMed Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G (2012) Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients. J Bone Joint Surg Am 94(11):1023–1029. doi:10.​2106/​JBJS.​K.​00927 CrossRefPubMed
6.
go back to reference Marimuthu K, Chen DB, Harris IA, Wheatley E, Bryant CJ, MacDessi SJ (2014) A multi-planar CT-based comparative analysis of patient-specific cutting guides with conventional instrumentation in total knee arthroplasty. J Arthroplasty 29(6):1138–1142. doi:10.1016/j.arth.2013.12.019 CrossRefPubMed Marimuthu K, Chen DB, Harris IA, Wheatley E, Bryant CJ, MacDessi SJ (2014) A multi-planar CT-based comparative analysis of patient-specific cutting guides with conventional instrumentation in total knee arthroplasty. J Arthroplasty 29(6):1138–1142. doi:10.​1016/​j.​arth.​2013.​12.​019 CrossRefPubMed
8.
go back to reference Boonen B, Schotanus MG, Kerens B, van der Weegen W, van Drumpt RA, Kort NP (2013) Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial. Knee Surg Sports Traumatol Arthrosc 21(10):2206–2212. doi:10.1007/s00167-013-2620-y CrossRefPubMed Boonen B, Schotanus MG, Kerens B, van der Weegen W, van Drumpt RA, Kort NP (2013) Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial. Knee Surg Sports Traumatol Arthrosc 21(10):2206–2212. doi:10.​1007/​s00167-013-2620-y CrossRefPubMed
9.
10.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMed
11.
go back to reference Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17(1):101–110CrossRefPubMed Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17(1):101–110CrossRefPubMed
13.
15.
go back to reference Hommel H, Perka C, Pfitzner T (2016) Preliminary results of a new surgical technique in total knee arthroplasty (TKA) using the native ligament tension for femoral implant positioning in varus osteoarthritis. Arch Orthop Trauma Surg 136(7):991–997. doi:10.1007/s00402-016-2480-2 CrossRefPubMed Hommel H, Perka C, Pfitzner T (2016) Preliminary results of a new surgical technique in total knee arthroplasty (TKA) using the native ligament tension for femoral implant positioning in varus osteoarthritis. Arch Orthop Trauma Surg 136(7):991–997. doi:10.​1007/​s00402-016-2480-2 CrossRefPubMed
17.
go back to reference Howell SM, Kuznik K, Hull ML, Siston RA (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31(9):857–863CrossRefPubMed Howell SM, Kuznik K, Hull ML, Siston RA (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31(9):857–863CrossRefPubMed
19.
go back to reference Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95-B(3):354–359. doi:10.1302/0301-620X.95B3.29903 CrossRefPubMed Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95-B(3):354–359. doi:10.​1302/​0301-620X.​95B3.​29903 CrossRefPubMed
22.
go back to reference Yan CH, Chiu KY, Ng FY, Chan PK, Fang CX (2015) Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 23(12):3637–3645. doi:10.1007/s00167-014-3264-2 CrossRefPubMed Yan CH, Chiu KY, Ng FY, Chan PK, Fang CX (2015) Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 23(12):3637–3645. doi:10.​1007/​s00167-014-3264-2 CrossRefPubMed
24.
go back to reference Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN, Chin PL (2014) The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(3):630–635. doi:10.1007/s00167-013-2638-1 CrossRefPubMed Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN, Chin PL (2014) The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(3):630–635. doi:10.​1007/​s00167-013-2638-1 CrossRefPubMed
25.
go back to reference Lee YS, Lee BK, Lee SH, Park HG, Jun DS, Moon do H (2013) Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs. Knee Surg Sports Traumatol Arthrosc 21(11):2542–2547. doi:10.1007/s00167-013-2419-x CrossRefPubMed Lee YS, Lee BK, Lee SH, Park HG, Jun DS, Moon do H (2013) Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs. Knee Surg Sports Traumatol Arthrosc 21(11):2542–2547. doi:10.​1007/​s00167-013-2419-x CrossRefPubMed
26.
go back to reference Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg Br 93(5):629–633. doi:10.1302/0301-620X.93B5.25893 CrossRefPubMed Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg Br 93(5):629–633. doi:10.​1302/​0301-620X.​93B5.​25893 CrossRefPubMed
28.
go back to reference Okamoto S, Mizu-Uchi H, Okazaki K, Hamai S, Tashiro Y, Nakahara H, Iwamoto Y (2016) Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24(1):229–235. doi:10.1007/s00167-014-3370-1 CrossRefPubMed Okamoto S, Mizu-Uchi H, Okazaki K, Hamai S, Tashiro Y, Nakahara H, Iwamoto Y (2016) Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24(1):229–235. doi:10.​1007/​s00167-014-3370-1 CrossRefPubMed
30.
31.
go back to reference Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472(1):263–271. doi:10.1007/s11999-013-2997-4 CrossRefPubMed Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472(1):263–271. doi:10.​1007/​s11999-013-2997-4 CrossRefPubMed
Metadata
Title
Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation
Authors
Kazumasa Yamamura
Yukihide Minoda
Shigekazu Mizokawa
Yoichi Ohta
Ryo Sugama
Suguru Nakamura
Hideki Ueyama
Hiroaki Nakamura
Publication date
01-03-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 3/2017
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2628-8

Other articles of this Issue 3/2017

Archives of Orthopaedic and Trauma Surgery 3/2017 Go to the issue