Abstract

Purpose

There are several methods for the refixation of the distal biceps tendon which show a variable complication rate. The aim of the present study was to evaluate the clinical outcome and complication rate after distal biceps repair in cortical button technique.

Methods

Clinical results, complications, strength of elbow flexion and supination and radiological evidence of heterotopic ossification in patients reporting persistent pain were evaluated in 27 male patients after an average of 36.1 month following distal biceps tendon repair in cortical button technique.

Results

The mean Mayo elbow performance score was 95.9 (SD 11.9), the mean disabilities of the arm, shoulder and hand score was 1.9 (SD 4.9) and the mean American shoulder and elbow surgeons (ASES) score was 94.6 (SD 11.6). The mean flexion and supination strength of the involved side relative to the uninvolved side was 91.7 % (SD 12.6) and 87.8 % (SD 15.9). Nine patients had 14 different complications including four transient lesions of the posterior interosseous nerve, two persistent lesions of the superficial branch of the radial nerve, one symptomatic massive heterotopic ossification and one disengaged cortical button. Three patients had six revisions. Patients with complications had a significantly lower relative supination strength, Mayo elbow performance score, ASES score, pain on VAS (p < 0.05 each) and satisfaction (p = 0.005).

Conclusions

As described for other techniques there is a high complication rate of distal biceps tendon repair in cortical button technique which resulted in inferior functional results and satisfaction. Surgeons treating patients with distal biceps tendon rupture should know the specific complications and know how to avoid them.

Level of evidence

Case series with no comparison group, Level IV.
Literature
1.
go back to reference Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using endobutton. J Should Elbow Surg 9:120–126CrossRef Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using endobutton. J Should Elbow Surg 9:120–126CrossRef
2.
go back to reference Baker BE, Bierwagen D (1985) Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Joint Surg Am 67:414–417PubMed Baker BE, Bierwagen D (1985) Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Joint Surg Am 67:414–417PubMed
3.
go back to reference Cain RA, Nydick JA, Stein MI, Williams BD, Polikandriotis JA, Hess AV (2012) Complications following distal biceps repair. J Hand Surg 37:2112–2117CrossRef Cain RA, Nydick JA, Stein MI, Williams BD, Polikandriotis JA, Hess AV (2012) Complications following distal biceps repair. J Hand Surg 37:2112–2117CrossRef
4.
go back to reference Citak M, Backhaus M, Seybold D, Suero EM, Schildhauer TA, Roetman B (2011) Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques. Knee Surg Sports Traumatol Arthrosc 19:1936–1941PubMedCrossRef Citak M, Backhaus M, Seybold D, Suero EM, Schildhauer TA, Roetman B (2011) Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques. Knee Surg Sports Traumatol Arthrosc 19:1936–1941PubMedCrossRef
5.
go back to reference Chavan PR, Duquin TR, Bisson LJ (2008) Repair of the ruptured distal biceps tendon: a systematic review. Am J Sports Med 36:1618–1624PubMedCrossRef Chavan PR, Duquin TR, Bisson LJ (2008) Repair of the ruptured distal biceps tendon: a systematic review. Am J Sports Med 36:1618–1624PubMedCrossRef
6.
go back to reference Chillemi C, Marinelli M, De Cupis V (2007) Rupture of the distal biceps brachii tendon: conservative treatment versus anatomic reinsertion—clinical and radiological evaluation after 2 years. Arch Orthop Trauma Surg 127:705–708PubMedCrossRef Chillemi C, Marinelli M, De Cupis V (2007) Rupture of the distal biceps brachii tendon: conservative treatment versus anatomic reinsertion—clinical and radiological evaluation after 2 years. Arch Orthop Trauma Surg 127:705–708PubMedCrossRef
7.
go back to reference Dillon MT, Lepore DJ (2011) Heterotopic ossification after single-incision distal biceps tendon repair with an endobutton. J Surg Orthop Adv 20:198–201PubMed Dillon MT, Lepore DJ (2011) Heterotopic ossification after single-incision distal biceps tendon repair with an endobutton. J Surg Orthop Adv 20:198–201PubMed
8.
go back to reference Dillon MT, Bollier MJ, King JC (2011) Repair of acute and chronic distal biceps tendon ruptures using the EndoButton. Hand 6:39–46PubMedCrossRef Dillon MT, Bollier MJ, King JC (2011) Repair of acute and chronic distal biceps tendon ruptures using the EndoButton. Hand 6:39–46PubMedCrossRef
9.
go back to reference Freeman CR, McCormick KR, Mahoney D, Baratz M, Lubahn JD (2009) Nonoperative treatment of distal biceps tendon ruptures compared with a historical control group. J Bone Joint Surg Am 91:2329–2334PubMedCrossRef Freeman CR, McCormick KR, Mahoney D, Baratz M, Lubahn JD (2009) Nonoperative treatment of distal biceps tendon ruptures compared with a historical control group. J Bone Joint Surg Am 91:2329–2334PubMedCrossRef
10.
go back to reference Gallinet D, Dietsch E, Barbier-Brion B, Lerais JM, Obert L (2011) Suture anchor reinsertion of distal biceps rupture: clinical results and radiological assessment of tendon healing. Orthop Traumatol Surg Res 97:252–259PubMedCrossRef Gallinet D, Dietsch E, Barbier-Brion B, Lerais JM, Obert L (2011) Suture anchor reinsertion of distal biceps rupture: clinical results and radiological assessment of tendon healing. Orthop Traumatol Surg Res 97:252–259PubMedCrossRef
11.
go back to reference Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Should Elbow Surg 12:484–490CrossRef Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Should Elbow Surg 12:484–490CrossRef
12.
go back to reference Heinzelmann AD, Savoie FH 3rd, Ramsey JR, Field LD, Mazzocca AD (2009) A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw. Am J Sports Med 37:989–994PubMedCrossRef Heinzelmann AD, Savoie FH 3rd, Ramsey JR, Field LD, Mazzocca AD (2009) A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw. Am J Sports Med 37:989–994PubMedCrossRef
13.
go back to reference Hetsroni I, Pilz-Burstein R, Nyska M, Back Z, Barchilon V, Mann G (2008) Avulsion of the distal biceps brachii tendon in middle-aged population: is surgical repair advisable? A comparative study of 22 patients treated with either nonoperative management or early anatomical repair. Injury 39:753–760PubMedCrossRef Hetsroni I, Pilz-Burstein R, Nyska M, Back Z, Barchilon V, Mann G (2008) Avulsion of the distal biceps brachii tendon in middle-aged population: is surgical repair advisable? A comparative study of 22 patients treated with either nonoperative management or early anatomical repair. Injury 39:753–760PubMedCrossRef
14.
go back to reference Kettler M, Tingart MJ, Lunger J, Kuhn V (2008) Reattachment of the distal tendon of biceps: factors affecting the failure strength of the repair. J Bone Joint Surg Br 90:103–106PubMed Kettler M, Tingart MJ, Lunger J, Kuhn V (2008) Reattachment of the distal tendon of biceps: factors affecting the failure strength of the repair. J Bone Joint Surg Br 90:103–106PubMed
15.
go back to reference Lo EY, Li CS, van den Boegaerde JM (2011) The effect of drill trajectory on proximity to the posterior interosseous nerve during cortical button distal biceps repair. Arthroscopy 27:1048–1054PubMedCrossRef Lo EY, Li CS, van den Boegaerde JM (2011) The effect of drill trajectory on proximity to the posterior interosseous nerve during cortical button distal biceps repair. Arthroscopy 27:1048–1054PubMedCrossRef
16.
go back to reference Mazzocca AD, Burton KJ, Romeo AA, Santangelo AS, Adams DA, Arciero DA (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258PubMedCrossRef Mazzocca AD, Burton KJ, Romeo AA, Santangelo AS, Adams DA, Arciero DA (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258PubMedCrossRef
17.
go back to reference Nesterenko S, Domire ZJ, Morrey BF, Sanchez-Sotelo J (2010) Elbow strength and endurance in patients with a ruptured distal biceps tendon. J Should Elbow Surg 19:184–189CrossRef Nesterenko S, Domire ZJ, Morrey BF, Sanchez-Sotelo J (2010) Elbow strength and endurance in patients with a ruptured distal biceps tendon. J Should Elbow Surg 19:184–189CrossRef
18.
go back to reference O’Driscoll SW, Goncalves LB, Dietz P (2007) The hook test for distal biceps tendon avulsion. Am J Sports Med 35:1865–1869PubMedCrossRef O’Driscoll SW, Goncalves LB, Dietz P (2007) The hook test for distal biceps tendon avulsion. Am J Sports Med 35:1865–1869PubMedCrossRef
19.
go back to reference Peeters T, Ching-Soon NG, Jansen N, Sneyers C, Declercq G, Verstreken F (2009) Functional outcome after repair of distal biceps tendon ruptures using endobutton technique. J Should Elbow Surg 18:283–287CrossRef Peeters T, Ching-Soon NG, Jansen N, Sneyers C, Declercq G, Verstreken F (2009) Functional outcome after repair of distal biceps tendon ruptures using endobutton technique. J Should Elbow Surg 18:283–287CrossRef
20.
go back to reference Rose DM, Archibald JD, Sutter EG, Belkoff SM, Wilckens JH (2011) Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire. Knee Surg Sports Traumatol Arthrosc 19:1019–1022PubMedCrossRef Rose DM, Archibald JD, Sutter EG, Belkoff SM, Wilckens JH (2011) Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire. Knee Surg Sports Traumatol Arthrosc 19:1019–1022PubMedCrossRef
21.
go back to reference Siebenlist S, Elser F, Sandmann GH, Buchholz A, Martetschläger F, Stöckle U, Lenich A (2011) The double intramedullary cortical button fixation for distal biceps tendon repair. Knee Surg Sports Traumatol Arthrosc 19:1915–1929CrossRef Siebenlist S, Elser F, Sandmann GH, Buchholz A, Martetschläger F, Stöckle U, Lenich A (2011) The double intramedullary cortical button fixation for distal biceps tendon repair. Knee Surg Sports Traumatol Arthrosc 19:1915–1929CrossRef
22.
go back to reference Schmidt CC, Diaz VA, Weir DM, Latona CR, Miller MC (2012) Repaired distal biceps magnetic resonance imaging anatomy compared with outcome. J Should Elbow Surg 21 Schmidt CC, Diaz VA, Weir DM, Latona CR, Miller MC (2012) Repaired distal biceps magnetic resonance imaging anatomy compared with outcome. J Should Elbow Surg 21
23.
go back to reference Vidal AF, Koonce RC, Wolcott M, Gonzales JB (2012) Extensive heterotopic ossification after suspensory cortical fixation of acute distal biceps tendon ruptures. Arthroscopy 28:1036–1140PubMedCrossRef Vidal AF, Koonce RC, Wolcott M, Gonzales JB (2012) Extensive heterotopic ossification after suspensory cortical fixation of acute distal biceps tendon ruptures. Arthroscopy 28:1036–1140PubMedCrossRef
Metadata
Title
High complication rate following distal biceps refixation with cortical button
Authors
Marc Banerjee
Sven Shafizadeh
Bertil Bouillon
Thorsten Tjardes
Arasch Wafaisade
Maurice Balke
Publication date
01-10-2013
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 10/2013
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-013-1819-1

Other articles of this Issue 10/2013

Archives of Orthopaedic and Trauma Surgery 10/2013 Go to the issue