Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2011

01-06-2011 | Elbow

Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire

Authors: David M. Rose, Jason D. Archibald, Edward G. Sutter, Stephen M. Belkoff, John H. Wilckens

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2011

Login to get access

Abstract

Purpose

Previous studies that have encouraged early postoperative motion after distal biceps repair shows little agreement on exactly when activity should be resumed after surgery or on the level of weight restriction that should be used. The aim of the current study was to define a service load that would permit, without failure, 2,000 cycles of immediate motion after single-incision EndoButton distal biceps repair with FiberWire.

Methods

In each of 15 cadaveric elbows, the distal biceps tendon was divided at its insertion and then repaired using a single-incision EndoButton technique with FiberWire. The repairs were then challenged according to the “staircase method” by cyclically loading the biceps tendon, so that the forearm flexed between 0° and 90°.

Results

The mean failure load of the repair was 166.7 N (95% confidence interval, 132.6–200.8). The data suggested that a 0.9 kg (9-N) weight at the hand was the limit for a 2,000-cycle early rehabilitation protocol after repair of a ruptured distal biceps tendon via a single-incision EndoButton repair technique.

Conclusion

Early active motion with a 0.9-kg weight restriction may therefore be possible in those patients undergoing distal biceps tendon repair using this technique.
Literature
1.
go back to reference An KN, Chao EYS, Kaufman KR (1991) Analysis of muscle and joint loads. In: Mow VC, Hayes WC (eds) Basic orthopaedic biomechanics. Raven Press, New York, pp 1–50 An KN, Chao EYS, Kaufman KR (1991) Analysis of muscle and joint loads. In: Mow VC, Hayes WC (eds) Basic orthopaedic biomechanics. Raven Press, New York, pp 1–50
2.
go back to reference An KN, Hui FC, Morrey BF, Linscheid RL, Chao EY (1981) Muscles across the elbow joint: a biomechanical analysis. J Biomech 14:659–669PubMedCrossRef An KN, Hui FC, Morrey BF, Linscheid RL, Chao EY (1981) Muscles across the elbow joint: a biomechanical analysis. J Biomech 14:659–669PubMedCrossRef
3.
go back to reference Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using the EndoButton. J Shoulder Elbow Surg 9:120–126PubMedCrossRef Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using the EndoButton. J Shoulder Elbow Surg 9:120–126PubMedCrossRef
4.
go back to reference Bisson LJ, de Perio JG, Weber AE, Ehrensberger MT, Buyea C (2007) Is it safe to perform aggressive rehabilitation after distal biceps tendon repair using the modified 2-incision approach? A biomechanical study. Am J Sports Med 35:2045–2050PubMedCrossRef Bisson LJ, de Perio JG, Weber AE, Ehrensberger MT, Buyea C (2007) Is it safe to perform aggressive rehabilitation after distal biceps tendon repair using the modified 2-incision approach? A biomechanical study. Am J Sports Med 35:2045–2050PubMedCrossRef
5.
go back to reference Chavan PR, Duquin TR, Bisson LJ (2008) Repair of the ruptured distal biceps tendon. A systematic review. Am J Sports Med 36:1618–1624PubMedCrossRef Chavan PR, Duquin TR, Bisson LJ (2008) Repair of the ruptured distal biceps tendon. A systematic review. Am J Sports Med 36:1618–1624PubMedCrossRef
6.
go back to reference Cheung EV, Lazarus M, Taranta M (2005) Immediate range of motion after distal biceps tendon repair. J Shoulder Elbow Surg 14:516–518PubMedCrossRef Cheung EV, Lazarus M, Taranta M (2005) Immediate range of motion after distal biceps tendon repair. J Shoulder Elbow Surg 14:516–518PubMedCrossRef
7.
go back to reference Cil A, Merten S, Steinmann SP (2009) Immediate active range of motion after modified 2-incision repair in acute distal biceps tendon rupture. Am J Sports Med 37:130–135PubMedCrossRef Cil A, Merten S, Steinmann SP (2009) Immediate active range of motion after modified 2-incision repair in acute distal biceps tendon rupture. Am J Sports Med 37:130–135PubMedCrossRef
8.
go back to reference Collins JA (1981) Failure of materials in mechanical design. Analysis, prediction, prevention. John Wiley, New York Collins JA (1981) Failure of materials in mechanical design. Analysis, prediction, prevention. John Wiley, New York
9.
go back to reference Collins JA (1981) Fatigue testing procedures and statistical interpretations of data. In: failure of materials in mechanical design analysis, prediction, prevention. John Wiley, New York, pp 360–378 Collins JA (1981) Fatigue testing procedures and statistical interpretations of data. In: failure of materials in mechanical design analysis, prediction, prevention. John Wiley, New York, pp 360–378
10.
go back to reference Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12:484–490PubMedCrossRef Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12:484–490PubMedCrossRef
11.
go back to reference Heinzelmann AD, Savoie FH III, Ramsey JR, Field LD, Mazzocca AD (2009) A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw. Am J Sports Med 37:989–994PubMedCrossRef Heinzelmann AD, Savoie FH III, Ramsey JR, Field LD, Mazzocca AD (2009) A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw. Am J Sports Med 37:989–994PubMedCrossRef
12.
go back to reference Kettler M, Lunger J, Kuhn V, Mutschler W, Tingart MJ (2007) Failure strengths in distal biceps tendon repair. Am J Sports Med 35:1544–1548PubMedCrossRef Kettler M, Lunger J, Kuhn V, Mutschler W, Tingart MJ (2007) Failure strengths in distal biceps tendon repair. Am J Sports Med 35:1544–1548PubMedCrossRef
14.
go back to reference Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adams DA, Arciero RA (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258PubMedCrossRef Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adams DA, Arciero RA (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258PubMedCrossRef
15.
go back to reference Morrey BF, Askew LJ, An KN, Dobyns JH (1985) Rupture of the distal tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 67:418–421PubMed Morrey BF, Askew LJ, An KN, Dobyns JH (1985) Rupture of the distal tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 67:418–421PubMed
16.
go back to reference Peeters T, Ching-Soon NG, Jansen N, Sneyers C, Declercq G, Verstreken F (2009) Functional outcome after repair of distal biceps tendon ruptures using the EndoButton technique. J Shoulder Elbow Surg 18:283–287PubMedCrossRef Peeters T, Ching-Soon NG, Jansen N, Sneyers C, Declercq G, Verstreken F (2009) Functional outcome after repair of distal biceps tendon ruptures using the EndoButton technique. J Shoulder Elbow Surg 18:283–287PubMedCrossRef
17.
go back to reference Safran MR, Graham SM (2002) Distal biceps tendon ruptures. Incidence, demographics, and the effect of smoking. Clin Orthop Relat Res 404:275–283PubMedCrossRef Safran MR, Graham SM (2002) Distal biceps tendon ruptures. Incidence, demographics, and the effect of smoking. Clin Orthop Relat Res 404:275–283PubMedCrossRef
18.
go back to reference Sethi P, Obopilwe E, Rincon L, Miller S, Mazzocca A (2009) Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation. J Shoulder Elbow Surg. doi:10.1016/j.jse.2009.05.007 Sethi P, Obopilwe E, Rincon L, Miller S, Mazzocca A (2009) Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation. J Shoulder Elbow Surg. doi:10.​1016/​j.​jse.​2009.​05.​007
19.
go back to reference Spang JT, Weinhold PS, Karas SG (2006) A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries. J Shoulder Elbow Surg 15:509–514PubMedCrossRef Spang JT, Weinhold PS, Karas SG (2006) A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries. J Shoulder Elbow Surg 15:509–514PubMedCrossRef
20.
go back to reference Spencer EE Jr, Tisdale A, Kostka K, Ivy RE (2008) Is therapy necessary after distal biceps tendon repair? Hand (N Y) 3:316–319 Spencer EE Jr, Tisdale A, Kostka K, Ivy RE (2008) Is therapy necessary after distal biceps tendon repair? Hand (N Y) 3:316–319
21.
go back to reference Sutton KM, Dodds SD, Ahmad CS, Sethi PM (2010) Surgical treatment of distal biceps rupture. J Am Acad Orthop Surg 18:139–148PubMed Sutton KM, Dodds SD, Ahmad CS, Sethi PM (2010) Surgical treatment of distal biceps rupture. J Am Acad Orthop Surg 18:139–148PubMed
Metadata
Title
Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire
Authors
David M. Rose
Jason D. Archibald
Edward G. Sutter
Stephen M. Belkoff
John H. Wilckens
Publication date
01-06-2011
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2011
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1348-1

Other articles of this Issue 6/2011

Knee Surgery, Sports Traumatology, Arthroscopy 6/2011 Go to the issue