Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 8/2012

01-08-2012 | Knee Arthroplasty

Fibrin sealants in orthopaedic surgery: practical experiences derived from use of QUIXIL® in total knee arthroplasty

Authors: Torsten Kluba, Katrin Fiedler, Beate Kunze, Ingmar Ipach, Andreas Suckel

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 8/2012

Login to get access

Abstract

Background

Total knee arthroplasty is associated with a significant postoperative blood loss even without any form of perioperative anticoagulation.

Methods

The potential role of QUIXIL®, a fibrin sealant used in orthopaedic surgery to control blood loss and avoid blood transfusions in patients undergoing total knee arthroplasty was evaluated in a prospective randomized trial with twenty-four patients diagnosed with primary osteoarthritis of the knee.

Results

Results showed that application of 2 ml QUIXIL® adds costs to treatment without reducing the number of transfused red blood cell counts and postoperative haemoglobin loss. However, significant lower levels of postoperative fluid loss (P = 0.026) was detected in QUIXIL® treated patients.

Conclusion

Regarding cost effectiveness and benefit no indication for the use of 2 ml QUIXIL® fibrin sealant in standard knee arthroplasty could be proofed statistically.
Literature
1.
go back to reference Lotke PA, Faralli VJ, Orenstein EM, Ecker ML (1991) Blood loss after total knee replacement: effect of tourniquet release and continuous passive motion. J Bone Joint Surg [Am] 73-A:1037–1040 Lotke PA, Faralli VJ, Orenstein EM, Ecker ML (1991) Blood loss after total knee replacement: effect of tourniquet release and continuous passive motion. J Bone Joint Surg [Am] 73-A:1037–1040
2.
go back to reference Sehat KR, Evans RL, Newman JH (2004) Hidden blood loss following hip and knee arthroplasty. J Bone Joint Surg [Br] 86-B:561–565 Sehat KR, Evans RL, Newman JH (2004) Hidden blood loss following hip and knee arthroplasty. J Bone Joint Surg [Br] 86-B:561–565
3.
go back to reference Tai TW, Lin IM, Chang CW, Lai KA, Yang CY (2011) Tourniquet use in total knee arthroplasty: a meta-analysis. Knee Sports Traumatol Arthroscop 19(7):1121–1130CrossRef Tai TW, Lin IM, Chang CW, Lai KA, Yang CY (2011) Tourniquet use in total knee arthroplasty: a meta-analysis. Knee Sports Traumatol Arthroscop 19(7):1121–1130CrossRef
4.
go back to reference Matziolis D, Perka C, Hube R, Matziolis G (2011) Influence of tourniquet ischemia on perioperative blood loss after total knee arthroplasty. Orthopade 40(2):178–182PubMedCrossRef Matziolis D, Perka C, Hube R, Matziolis G (2011) Influence of tourniquet ischemia on perioperative blood loss after total knee arthroplasty. Orthopade 40(2):178–182PubMedCrossRef
5.
go back to reference Lemaire R (2008) Strategies for blood management in orthopaedic and trauma surgery. J Bone Joint Surg [Br] 90-B:1128–1136CrossRef Lemaire R (2008) Strategies for blood management in orthopaedic and trauma surgery. J Bone Joint Surg [Br] 90-B:1128–1136CrossRef
6.
go back to reference Goodnough LT, Shander A (2007) Blood management. Arch Pathol Lab Med 131:695–701PubMed Goodnough LT, Shander A (2007) Blood management. Arch Pathol Lab Med 131:695–701PubMed
7.
go back to reference Li B, Liu D, Tian L (2011) The effect of knee position on blood loss and range of motion following total knee arthroplasty. Knee Sports Traumatol Arthrosc (Epub ahead) Li B, Liu D, Tian L (2011) The effect of knee position on blood loss and range of motion following total knee arthroplasty. Knee Sports Traumatol Arthrosc (Epub ahead)
8.
go back to reference Kerr Dr, Kohan L (2008) Local infiltration analgesia: a technique for the control of acute postoperative pain following knee and hip surgery: a case study of 325 patients. Acta Orthop 79(2):174–183PubMedCrossRef Kerr Dr, Kohan L (2008) Local infiltration analgesia: a technique for the control of acute postoperative pain following knee and hip surgery: a case study of 325 patients. Acta Orthop 79(2):174–183PubMedCrossRef
9.
go back to reference Aksoy Y, Altinel L, Köse KC (2011) The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthop Traumatol Turc 45(3):190–194PubMedCrossRef Aksoy Y, Altinel L, Köse KC (2011) The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthop Traumatol Turc 45(3):190–194PubMedCrossRef
10.
go back to reference Charoencholvanich K, Siriwattansakul P (2011) Tranexamic acid reduced blood loss and blood transfusion after TKA: a prospective randomized controlled trial. Clin Orthop Relat Res (Epub ahead) Charoencholvanich K, Siriwattansakul P (2011) Tranexamic acid reduced blood loss and blood transfusion after TKA: a prospective randomized controlled trial. Clin Orthop Relat Res (Epub ahead)
11.
go back to reference Gardner MJ, Demetrakopoulos D, Klepchick PR, Mooar PA (2007) The efficacy of autologous platelet gel in pain control and blood loss in total knee arthroplasty. Int Orthop (SICOT) 31:309–313CrossRef Gardner MJ, Demetrakopoulos D, Klepchick PR, Mooar PA (2007) The efficacy of autologous platelet gel in pain control and blood loss in total knee arthroplasty. Int Orthop (SICOT) 31:309–313CrossRef
12.
go back to reference Levy O, Martinovitz U, Oran A, Tauber C, Horoszowski H (1999) The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. a prospective, randomized, multicenter study. J Bone Joint Surg [Am] 81:1580–1588 Levy O, Martinovitz U, Oran A, Tauber C, Horoszowski H (1999) The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. a prospective, randomized, multicenter study. J Bone Joint Surg [Am] 81:1580–1588
13.
go back to reference Everts PAM, Devilee RJJ, Oosterbos CJM, Mahoney CB, Schattenkerk ME, Knape JTA, Van Zundert A (2007) Autologous platelet gel and fibrin sealant enhance the efficacy of total knee arthroplasty: improved range of motion, decreased length of stay and a reduced incidence of arthrofibrosis. Knee Surg Sports Traumatol Arthrosc 15:888–894PubMedCrossRef Everts PAM, Devilee RJJ, Oosterbos CJM, Mahoney CB, Schattenkerk ME, Knape JTA, Van Zundert A (2007) Autologous platelet gel and fibrin sealant enhance the efficacy of total knee arthroplasty: improved range of motion, decreased length of stay and a reduced incidence of arthrofibrosis. Knee Surg Sports Traumatol Arthrosc 15:888–894PubMedCrossRef
14.
go back to reference Mawatari M, Higo T, Tsutsumi Y, Shigematsu M, Hotokebuchi T (2006) Effectiveness of autologous fibrin tissue adhesive in reducing postoperative blood loss during total hip arthroplasty: a prospective randomised study of 100 cases. J Orthop Surgery 14(2):117–121 Mawatari M, Higo T, Tsutsumi Y, Shigematsu M, Hotokebuchi T (2006) Effectiveness of autologous fibrin tissue adhesive in reducing postoperative blood loss during total hip arthroplasty: a prospective randomised study of 100 cases. J Orthop Surgery 14(2):117–121
15.
go back to reference Steinhubl SR, Bhatt DL, Brennan DM, Montalescot G, Hankey GJ, Eikelboom JW, Berger PB, Topol EJ (2009) Aspirin to prevent cardiovascular disease: the association of aspirin dose and clopidogrel with thrombosis and bleeding. Ann Inter Med 150:379–386 Steinhubl SR, Bhatt DL, Brennan DM, Montalescot G, Hankey GJ, Eikelboom JW, Berger PB, Topol EJ (2009) Aspirin to prevent cardiovascular disease: the association of aspirin dose and clopidogrel with thrombosis and bleeding. Ann Inter Med 150:379–386
16.
go back to reference Gogarten W, Van Aken H (2009) Die neue S3-Leitlinie zur Thromboembolieprophylaxe-Bedeutung für unser Fachgebiet. Anästh Intensivmed 50:316–323 Gogarten W, Van Aken H (2009) Die neue S3-Leitlinie zur Thromboembolieprophylaxe-Bedeutung für unser Fachgebiet. Anästh Intensivmed 50:316–323
17.
go back to reference Carless PA, Henry DA, Anthony DM (2003) Fibrin sealant use for minimising per-operative allogenic blood transfusion. Cochrane Database Syst Rev Issue 1. Art. No.: CD004171. doi:10.1002/14651858.CD004171 Carless PA, Henry DA, Anthony DM (2003) Fibrin sealant use for minimising per-operative allogenic blood transfusion. Cochrane Database Syst Rev Issue 1. Art. No.: CD004171. doi:10.​1002/​14651858.​CD004171
19.
go back to reference McManus KT, Velchik MG, Alavi A, Lotke PA (1987) Non-invasive assessment of postoperative bleeding in TKA patients with Tc-99m RBCs. J Nuclear Med 28:565 McManus KT, Velchik MG, Alavi A, Lotke PA (1987) Non-invasive assessment of postoperative bleeding in TKA patients with Tc-99m RBCs. J Nuclear Med 28:565
Metadata
Title
Fibrin sealants in orthopaedic surgery: practical experiences derived from use of QUIXIL® in total knee arthroplasty
Authors
Torsten Kluba
Katrin Fiedler
Beate Kunze
Ingmar Ipach
Andreas Suckel
Publication date
01-08-2012
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2012
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-012-1519-2

Other articles of this Issue 8/2012

Archives of Orthopaedic and Trauma Surgery 8/2012 Go to the issue