Abstract

Complications while removing implants are quite common. In rare cases screw shanks must be left in situ. We present a case of a 38-year-old patient who was treated using a palmar locking plate for a distal radius fracture. After implant removal, one of the screw shanks left in situ penetrated the dorsal cortex of the distal radius into the third extensor tendon compartment and led to irritation of the extensor pollicis longus tendon. We report the unexpected complication and analysis of possible errors of this case to avoid this kind of complication.
Literature
1.
go back to reference Arora R, Lutz M, Hennerbichler A et al (2007) Complications followingp internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322PubMedCrossRef Arora R, Lutz M, Hennerbichler A et al (2007) Complications followingp internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322PubMedCrossRef
2.
go back to reference Hattori Y, Doi K, Sakamoto S et al (2008) Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture. Hand Surg 13(3):183–185PubMedCrossRef Hattori Y, Doi K, Sakamoto S et al (2008) Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture. Hand Surg 13(3):183–185PubMedCrossRef
3.
go back to reference Benson EC, DeCarvalho A, Mikola EA et al (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res. 451:218–222PubMedCrossRef Benson EC, DeCarvalho A, Mikola EA et al (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res. 451:218–222PubMedCrossRef
4.
go back to reference Björkman A, Jörgsholm P (2004) Rupture of the extensor pollicis longus tendon: a study of aetiological factors. Scand J Plast Reconstr Surg Hand Surg 38(1):32–35PubMedCrossRef Björkman A, Jörgsholm P (2004) Rupture of the extensor pollicis longus tendon: a study of aetiological factors. Scand J Plast Reconstr Surg Hand Surg 38(1):32–35PubMedCrossRef
5.
go back to reference Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31(3):359–365PubMedCrossRef Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31(3):359–365PubMedCrossRef
6.
go back to reference Ehlinger M, Adam P, Simon P et al (2009) Technical difficulties in hardware removal in titanium compression plates with locking screws. Orthop Traumatol Surg Res 95(5):373–376PubMedCrossRef Ehlinger M, Adam P, Simon P et al (2009) Technical difficulties in hardware removal in titanium compression plates with locking screws. Orthop Traumatol Surg Res 95(5):373–376PubMedCrossRef
7.
go back to reference Bae JH, Oh JK, Oh CW et al (2009) Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg 129(1):91–95PubMedCrossRef Bae JH, Oh JK, Oh CW et al (2009) Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg 129(1):91–95PubMedCrossRef
8.
go back to reference Hamilton P, Doig S, Williamson O (2004) Technical difficulty of metal removal after LISS plating. Injury 35:626–628PubMedCrossRef Hamilton P, Doig S, Williamson O (2004) Technical difficulty of metal removal after LISS plating. Injury 35:626–628PubMedCrossRef
9.
go back to reference Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium. J Orthop Trauma 21(10 Suppl.):S1–S133PubMedCrossRef Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium. J Orthop Trauma 21(10 Suppl.):S1–S133PubMedCrossRef
10.
go back to reference Orbay JL (2000) The treatment of unstable distal radius fractures with volar fixation. Hand Surg 5(2):103–112PubMedCrossRef Orbay JL (2000) The treatment of unstable distal radius fractures with volar fixation. Hand Surg 5(2):103–112PubMedCrossRef
11.
go back to reference Kirchhoff C, Braunstein, Kirchhoff S et al (2008) Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord 12(9):138CrossRef Kirchhoff C, Braunstein, Kirchhoff S et al (2008) Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord 12(9):138CrossRef
12.
go back to reference Jupiter JB, Fernandez DL, Toh CL (1996) The operative management of volar articular fractures of the distal end of the radius. J Bone Joint Surg Am 78:1817–1828PubMed Jupiter JB, Fernandez DL, Toh CL (1996) The operative management of volar articular fractures of the distal end of the radius. J Bone Joint Surg Am 78:1817–1828PubMed
13.
go back to reference McQueen M, Caspers J (1988) Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Am 70:649–651 McQueen M, Caspers J (1988) Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Am 70:649–651
14.
go back to reference Georgiadis GM, Gove NK, Smith AD et al (2004) Removal of the less invasive stabilization system. J Orthop Trauma 18:562–564PubMedCrossRef Georgiadis GM, Gove NK, Smith AD et al (2004) Removal of the less invasive stabilization system. J Orthop Trauma 18:562–564PubMedCrossRef
15.
go back to reference Pichler W, Grechenig W, Clement H et al (2009) Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius. J Hand Surg Eur Vol 34(3):333–335PubMedCrossRef Pichler W, Grechenig W, Clement H et al (2009) Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius. J Hand Surg Eur Vol 34(3):333–335PubMedCrossRef
Metadata
Title
Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
Authors
Luzian C. P. Haug
Christian Deml
Michael Blauth
Rohit Arora
Publication date
01-09-2011
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 9/2011
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1300-y

Other articles of this Issue 9/2011

Archives of Orthopaedic and Trauma Surgery 9/2011 Go to the issue