Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 4/2011

01-04-2011 | Osteoporotic Fracture Management

Management of proximal humeral fractures in elderly patients with uni- or polyaxial locking osteosynthesis system

Authors: Hong-fei Shi, Jin Xiong, Yi-xin Chen, Jun-fei Wang, Shou-feng Wang, Zhi-jun Chen, Yong Qiu

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 4/2011

Login to get access

Abstract

Introduction

To evaluate the clinical efficacy of uni- and polyaxial locking osteosynthesis systems in the management of proximal humeral fractures in elderly patients, totally 76 cases were reviewed including 18 cases of two-part (Neer classification), 36 cases of three-part, and 22 cases of four-part fractures.

Methods

All the patients received open reduction and internal fixation with proximal humerus internal locking osteosynthesis system (PHILOS) or Numelock systems designed for proximal humerus.

Results

Results showed no significant difference between groups considering the Constant–Murley scores assessed at 6 and 12 months, postoperatively. Satisfactory outcomes were achieved in 73.7 and 75.0% of the patients from the PHILOS and Numelock groups, respectively. Complications included four cases of varus malunion, one case of screw cut-out, and another case of avascular necrosis.

Conclusion

Both of the PHILOS and Numelock systems showed equally good results considering fixation stability and functional outcomes of proximal humeral fractures in elderly patients.
Literature
1.
2.
go back to reference Fakler JK, Hogan C, Heyde CE, John T (2008) Current concepts in the treatment of proximal humeral fractures. Orthopedics 31(1):42–51PubMedCrossRef Fakler JK, Hogan C, Heyde CE, John T (2008) Current concepts in the treatment of proximal humeral fractures. Orthopedics 31(1):42–51PubMedCrossRef
3.
go back to reference Drosdowech DS, Faber KJ, Athwal GS (2008) Open reduction and internal fixation of proximal humerus fractures. Orthop Clin North Am 39(4):429–439PubMedCrossRef Drosdowech DS, Faber KJ, Athwal GS (2008) Open reduction and internal fixation of proximal humerus fractures. Orthop Clin North Am 39(4):429–439PubMedCrossRef
4.
go back to reference Magovern B, Ramsey ML (2008) Percutaneous fixation of proximal humerus fractures. Orthop Clin North Am 39(4):405–416PubMedCrossRef Magovern B, Ramsey ML (2008) Percutaneous fixation of proximal humerus fractures. Orthop Clin North Am 39(4):405–416PubMedCrossRef
5.
go back to reference Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P (2009) Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg 18(6):837–844PubMedCrossRef Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P (2009) Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg 18(6):837–844PubMedCrossRef
6.
go back to reference Mittlmeier TW, Stedtfeld HW, Ewert A, Beck M, Frosch B, Gradl G (2003) Stabilization of proximal humeral fractures with an angular and sliding stable antegrade locking nail (targon ph). J Bone Joint Surg 85A(Suppl 4):136–146 Mittlmeier TW, Stedtfeld HW, Ewert A, Beck M, Frosch B, Gradl G (2003) Stabilization of proximal humeral fractures with an angular and sliding stable antegrade locking nail (targon ph). J Bone Joint Surg 85A(Suppl 4):136–146
8.
go back to reference Badman BL, Mighell M (2008) Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures. J Am Acad Orthop Surg 16(5):294–302PubMed Badman BL, Mighell M (2008) Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures. J Am Acad Orthop Surg 16(5):294–302PubMed
9.
go back to reference Roderer G, Gebhard F, Krischak G, Wilke HJ, Claes L (2010) Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. Int Orthop Roderer G, Gebhard F, Krischak G, Wilke HJ, Claes L (2010) Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. Int Orthop
10.
go back to reference Ricchetti ET, Warrender WJ, Abboud JA (2010) Use of locking plates in the treatment of proximal humerus fractures. J Shoulder Elbow Surg 19(2 Suppl):66–75PubMedCrossRef Ricchetti ET, Warrender WJ, Abboud JA (2010) Use of locking plates in the treatment of proximal humerus fractures. J Shoulder Elbow Surg 19(2 Suppl):66–75PubMedCrossRef
11.
go back to reference Bjorkenheim JM, Pajarinen J, Savolainen V (2004) Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 75(6):741–745PubMedCrossRef Bjorkenheim JM, Pajarinen J, Savolainen V (2004) Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 75(6):741–745PubMedCrossRef
12.
go back to reference Wijgman AJ, Roolker W, Patt TW, Raaymakers EL, Marti RK (2002) Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus. J Bone Joint Surg 84-A(11):1919–1925PubMed Wijgman AJ, Roolker W, Patt TW, Raaymakers EL, Marti RK (2002) Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus. J Bone Joint Surg 84-A(11):1919–1925PubMed
13.
14.
go back to reference Duralde XA, Leddy LR (2010) The results of orif of displaced unstable proximal humeral fractures using a locking plate. Journal of shoulder and elbow surgery/American Shoulder and Elbow Surgeons [et al. 19 (4):480-488 Duralde XA, Leddy LR (2010) The results of orif of displaced unstable proximal humeral fractures using a locking plate. Journal of shoulder and elbow surgery/American Shoulder and Elbow Surgeons [et al. 19 (4):480-488
15.
go back to reference Gao H, Zhang CQ, Luo CF, Zhou ZB, Zeng BF (2009) Fractures of the distal tibia treated with polyaxial locking plating. Clin Orthop Relat Res 467(3):831–837PubMedCrossRef Gao H, Zhang CQ, Luo CF, Zhou ZB, Zeng BF (2009) Fractures of the distal tibia treated with polyaxial locking plating. Clin Orthop Relat Res 467(3):831–837PubMedCrossRef
16.
go back to reference Otto RJ, Moed BR, Bledsoe JG (2009) Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures. J Orthop Trauma 23(9):645–652PubMedCrossRef Otto RJ, Moed BR, Bledsoe JG (2009) Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures. J Orthop Trauma 23(9):645–652PubMedCrossRef
17.
go back to reference Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG (2007) The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma 21(3):185–191PubMedCrossRef Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG (2007) The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma 21(3):185–191PubMedCrossRef
18.
go back to reference Robinson BC, Athwal GS, Sanchez-Sotelo J, Rispoli DM (2008) Classification and imaging of proximal humerus fractures. Orthop Clin North Am 39(4):393–403PubMedCrossRef Robinson BC, Athwal GS, Sanchez-Sotelo J, Rispoli DM (2008) Classification and imaging of proximal humerus fractures. Orthop Clin North Am 39(4):393–403PubMedCrossRef
19.
go back to reference Agudelo J, Schurmann M, Stahel P, Helwig P, Morgan SJ, Zechel W, Bahrs C, Parekh A, Ziran B, Williams A, Smith W (2007) Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma 21(10):676–681PubMedCrossRef Agudelo J, Schurmann M, Stahel P, Helwig P, Morgan SJ, Zechel W, Bahrs C, Parekh A, Ziran B, Williams A, Smith W (2007) Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma 21(10):676–681PubMedCrossRef
20.
go back to reference Kettler M, Biberthaler P, Braunstein V, Zeiler C, Kroetz M, Mutschler W (2006) Treatment of proximal humeral fractures with the philos angular stable plate. Presentation of 225 cases of dislocated fractures. Unfallchirurg 109(12):1032–1040PubMedCrossRef Kettler M, Biberthaler P, Braunstein V, Zeiler C, Kroetz M, Mutschler W (2006) Treatment of proximal humeral fractures with the philos angular stable plate. Presentation of 225 cases of dislocated fractures. Unfallchirurg 109(12):1032–1040PubMedCrossRef
21.
go back to reference Koukakis A, Apostolou CD, Taneja T, Korres DS, Amini A (2006) Fixation of proximal humerus fractures using the philos plate: Early experience. Clin Orthop Relat Res 442:115–120PubMedCrossRef Koukakis A, Apostolou CD, Taneja T, Korres DS, Amini A (2006) Fixation of proximal humerus fractures using the philos plate: Early experience. Clin Orthop Relat Res 442:115–120PubMedCrossRef
22.
go back to reference Moonot P, Ashwood N, Hamlet M (2007) Early results for treatment of three- and four-part fractures of the proximal humerus using the philos plate system. J Bone Joint Surg Br 89(9):1206–1209PubMedCrossRef Moonot P, Ashwood N, Hamlet M (2007) Early results for treatment of three- and four-part fractures of the proximal humerus using the philos plate system. J Bone Joint Surg Br 89(9):1206–1209PubMedCrossRef
23.
go back to reference Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audige L, Babst R (2009) Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 23(3):163–172PubMedCrossRef Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audige L, Babst R (2009) Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 23(3):163–172PubMedCrossRef
24.
go back to reference Papadopoulos P, Karataglis D, Stavridis SI, Petsatodis G, Christodoulou A (2009) Mid-term results of internal fixation of proximal humeral fractures with the philos plate. Injury 40(12):1292–1296PubMedCrossRef Papadopoulos P, Karataglis D, Stavridis SI, Petsatodis G, Christodoulou A (2009) Mid-term results of internal fixation of proximal humeral fractures with the philos plate. Injury 40(12):1292–1296PubMedCrossRef
25.
go back to reference Ockert B, Braunstein V, Kirchhoff C, Korner M, Kirchhoff S, Kehr K, Mutschler W, Biberthaler P (2010) Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study. J Trauma Ockert B, Braunstein V, Kirchhoff C, Korner M, Kirchhoff S, Kehr K, Mutschler W, Biberthaler P (2010) Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study. J Trauma
Metadata
Title
Management of proximal humeral fractures in elderly patients with uni- or polyaxial locking osteosynthesis system
Authors
Hong-fei Shi
Jin Xiong
Yi-xin Chen
Jun-fei Wang
Shou-feng Wang
Zhi-jun Chen
Yong Qiu
Publication date
01-04-2011
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 4/2011
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-010-1199-8

Other articles of this Issue 4/2011

Archives of Orthopaedic and Trauma Surgery 4/2011 Go to the issue