Published in: Heart and Vessels 5/2016

01-05-2016 | Original Article

Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention

Authors: Shigeru Nakamura, Tomoko Kobayashi, Atsushi Funatsu, Tadahisa Okada, Maria Mauti, Yuki Waizumi, Shinichi Yamada

Published in: Heart and Vessels | Issue 5/2016

Login to get access

Abstract

Coronary angiography and intervention can expose patients to high radiation dose. This retrospective study quantifies the patient dose reduction due to the introduction of a novel X-ray imaging noise reduction technology using advanced real-time image noise reduction algorithms and optimized acquisition chain for fluoroscopy and exposure in interventional cardiology. Patient, procedure and radiation dose data were retrospectively collected in the period August 2012–August 2013 for 883 patients treated with the image noise reduction technology (referred as “new system”). The same data were collected for 1083 patients in the period April 2011–July 2012 with a system using state-of-the-art image processing and reference acquisition chain (referred as “reference system”). Procedures were divided into diagnostic (CAG) and intervention (PCI). Acquisition parameters such as fluoroscopy time, volume of contrast medium, number of exposure images and number of stored fluoroscopy images were collected to classify procedure complexity. The procedural dose reduction was investigated separately for three main cardiologists. The new system provides significant dose reduction compared to the reference system. Median DAP values decreased for all procedures (p < 0.0001) from 172.7 to 59.4 Gy cm2, for CAG from 155.1 to 52.0 Gy cm2 and for PCI from 229.0 to 85.8 Gy cm2 with reduction quantified at 66, 66 and 63 %, respectively. Based on median values, the dose reduction for all procedures was 68, 60 and 67 % for cardiologists 1, 2 and 3, respectively. The X-ray imaging technology combining advanced real-time image noise reduction algorithms and anatomy-specific optimized fluoroscopy and cine acquisition chain provides 66 % patient dose reduction in interventional cardiology.
Appendix
Available only for authorised users
Literature
1.
go back to reference Trianni A, Chizzola G, Toh H, Quai E, Cragnolini E, Bernardi G, Proclemer A, Padovani R (2005) Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology. Radiat Prot Dosimetry 117(1–3):241–246PubMed Trianni A, Chizzola G, Toh H, Quai E, Cragnolini E, Bernardi G, Proclemer A, Padovani R (2005) Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology. Radiat Prot Dosimetry 117(1–3):241–246PubMed
2.
go back to reference Kaneko H, Yajima J, Oikawa Y, Tanaka S, Fukamachi D, Suzuki S, Sagara K, Otsuka T, Matsuno S, Funada R, Kano H, Uejima T, Koike A, Nagashima K, Kirigaya H, Sawada H, Aizawa T, Yamashita T (2014) Impact of aging on the clinical outcomes of Japanese patients with coronary artery disease after percutaneous coronary intervention. Heart Vessels 29(2):156–164CrossRefPubMedPubMedCentral Kaneko H, Yajima J, Oikawa Y, Tanaka S, Fukamachi D, Suzuki S, Sagara K, Otsuka T, Matsuno S, Funada R, Kano H, Uejima T, Koike A, Nagashima K, Kirigaya H, Sawada H, Aizawa T, Yamashita T (2014) Impact of aging on the clinical outcomes of Japanese patients with coronary artery disease after percutaneous coronary intervention. Heart Vessels 29(2):156–164CrossRefPubMedPubMedCentral
3.
go back to reference Picano E, Santoro G, Vano E (2007) Sustainability in the cardiac cath lab. Int J Cardiovasc Imaging 23(2):143–147CrossRefPubMed Picano E, Santoro G, Vano E (2007) Sustainability in the cardiac cath lab. Int J Cardiovasc Imaging 23(2):143–147CrossRefPubMed
4.
go back to reference Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, Shah ND, Nasir K, Einstein AJ, Nallamothu BK (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361(9):849–857CrossRefPubMedPubMedCentral Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, Shah ND, Nasir K, Einstein AJ, Nallamothu BK (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361(9):849–857CrossRefPubMedPubMedCentral
5.
go back to reference Strauss KJ, Kaste SC (2006) The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients—a white paper executive summary. Pediatr Radiol 36(2):110–112CrossRefPubMedPubMedCentral Strauss KJ, Kaste SC (2006) The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients—a white paper executive summary. Pediatr Radiol 36(2):110–112CrossRefPubMedPubMedCentral
6.
go back to reference Dekker LRC, van der Voort PH, Simmers TA, Verbeek XAAM, Bullens RWM, van’t Veer M, Brands PJM, Meijer A (2013) New image processing and noise reduction technology allows reduction of radiation exposure in complex electrophysiologic interventions while maintaining optimal image quality: A randomized clinical trial. Heart Rhythm 10(11):1678–1682CrossRefPubMed Dekker LRC, van der Voort PH, Simmers TA, Verbeek XAAM, Bullens RWM, van’t Veer M, Brands PJM, Meijer A (2013) New image processing and noise reduction technology allows reduction of radiation exposure in complex electrophysiologic interventions while maintaining optimal image quality: A randomized clinical trial. Heart Rhythm 10(11):1678–1682CrossRefPubMed
7.
go back to reference Soderman M, Mauti M, Boon S, Omar A, Marteinsdóttir M, Andersson T, Holmin S, Hoornaert B (2013) Radiation dose in neuroangiography using image noise reduction technology: a population study based on 614 patients. Neuroradiology 55:1365–1372CrossRefPubMedPubMedCentral Soderman M, Mauti M, Boon S, Omar A, Marteinsdóttir M, Andersson T, Holmin S, Hoornaert B (2013) Radiation dose in neuroangiography using image noise reduction technology: a population study based on 614 patients. Neuroradiology 55:1365–1372CrossRefPubMedPubMedCentral
8.
go back to reference Söderman M, Holmin S, Andersson T, Palmgren C, Babić D, Hoornaert B (2013) Clinical results with an image noise reduction algorithm for digital subtraction angiography. Radiology 269(2):553–560CrossRefPubMed Söderman M, Holmin S, Andersson T, Palmgren C, Babić D, Hoornaert B (2013) Clinical results with an image noise reduction algorithm for digital subtraction angiography. Radiology 269(2):553–560CrossRefPubMed
9.
go back to reference Racadio J, Strauss K, Abruzzo T, Patel M, Kukreja K, Johnson N, den Hartog M, Hoornaert B, Nachabe R (2014) Significant dose reduction for pediatric digital subtraction angiography without impairing image quality: preclinical study in a piglet model. Am J Roentgenol 203:904–908CrossRef Racadio J, Strauss K, Abruzzo T, Patel M, Kukreja K, Johnson N, den Hartog M, Hoornaert B, Nachabe R (2014) Significant dose reduction for pediatric digital subtraction angiography without impairing image quality: preclinical study in a piglet model. Am J Roentgenol 203:904–908CrossRef
10.
go back to reference Farshid A, Chandrasekhar J, McLean D (2014) Benefits of dual-axis rotational coronary angiography in routine clinical practice. Heart Vessels 29(2):199–205CrossRefPubMed Farshid A, Chandrasekhar J, McLean D (2014) Benefits of dual-axis rotational coronary angiography in routine clinical practice. Heart Vessels 29(2):199–205CrossRefPubMed
11.
go back to reference Ogita M, Sakakura K, Nakamura T, Funayama H, Wada H, Naito R, Sugawara Y, Kubo N, Ako J, Momomura S (2012) Association between deteriorated renal function and long-term clinical outcomes after percutaneous coronary intervention. Heart Vessels 27(5):460–467CrossRefPubMed Ogita M, Sakakura K, Nakamura T, Funayama H, Wada H, Naito R, Sugawara Y, Kubo N, Ako J, Momomura S (2012) Association between deteriorated renal function and long-term clinical outcomes after percutaneous coronary intervention. Heart Vessels 27(5):460–467CrossRefPubMed
12.
go back to reference Matejka J, Varvarovsky I, Vojtisek P, Herman A, Rozsival V, Borkova V, Kvasnicka J (2010) Prevention of contrast-induced acute kidney injury by theophylline in elderly patients with chronic kidney disease. Heart Vessels 25(6):536–542CrossRefPubMed Matejka J, Varvarovsky I, Vojtisek P, Herman A, Rozsival V, Borkova V, Kvasnicka J (2010) Prevention of contrast-induced acute kidney injury by theophylline in elderly patients with chronic kidney disease. Heart Vessels 25(6):536–542CrossRefPubMed
13.
go back to reference Grantham JA, Marso SP, Spertus J, House J, Holmes DR Jr, Rutherford BD (2009) Chronic total occlusion angioplasty in the United States. JACC Cardiovasc Interv 2(6):479–486CrossRefPubMed Grantham JA, Marso SP, Spertus J, House J, Holmes DR Jr, Rutherford BD (2009) Chronic total occlusion angioplasty in the United States. JACC Cardiovasc Interv 2(6):479–486CrossRefPubMed
14.
go back to reference Tsapaki V, Kottou S, Vano E, Faulkner K, Giannouleas J, Padovani R, Kyrozi E, Koutelou M, Vardalaki E, Neofotistou V (2003) Patient dose values in a dedicated Greek cardiac centre. Br J Radiol 76:726–730CrossRefPubMed Tsapaki V, Kottou S, Vano E, Faulkner K, Giannouleas J, Padovani R, Kyrozi E, Koutelou M, Vardalaki E, Neofotistou V (2003) Patient dose values in a dedicated Greek cardiac centre. Br J Radiol 76:726–730CrossRefPubMed
15.
16.
go back to reference Bar O, Maccia C, Pagès P, Blanchard D (2008) A multicentre survey of patient exposure to ionising radiation during interventional cardiology procedures in France. Euro Interv 3(5):593–599 Bar O, Maccia C, Pagès P, Blanchard D (2008) A multicentre survey of patient exposure to ionising radiation during interventional cardiology procedures in France. Euro Interv 3(5):593–599
17.
go back to reference Cui Y, Zhang H, Zheng J, Yang X, Liang C (2013) An investigation of patient doses during coronary interventional procedures in China. Radiat Prot Dosim 156(3):296–302CrossRef Cui Y, Zhang H, Zheng J, Yang X, Liang C (2013) An investigation of patient doses during coronary interventional procedures in China. Radiat Prot Dosim 156(3):296–302CrossRef
18.
go back to reference Bogaert E, Bacher K, Lemmens K, Carlier M, Desmet W, De Wagter X, Djian D, Hanet C, Heyndrickx G, Legrand V, Taeymans Y, Thierens H (2009) A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels. Br J Radiol 82(976):303–312CrossRefPubMed Bogaert E, Bacher K, Lemmens K, Carlier M, Desmet W, De Wagter X, Djian D, Hanet C, Heyndrickx G, Legrand V, Taeymans Y, Thierens H (2009) A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels. Br J Radiol 82(976):303–312CrossRefPubMed
19.
go back to reference Sadick V, Reed W, Collins L, Sadick N, Heard R, Robinson J (2010) Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty. Br J Radiol 83(989):379–394CrossRefPubMedPubMedCentral Sadick V, Reed W, Collins L, Sadick N, Heard R, Robinson J (2010) Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty. Br J Radiol 83(989):379–394CrossRefPubMedPubMedCentral
20.
go back to reference Tsapaki V, Ahmed NA, AlSuwaidi JS, Beganovic A, Benider A, BenOmrane L, Borisova R, Economides S, El-Nachef L, Faj D, Hovhannesyan A, Kharita MH, Khelassi-Toutaoui N, Manatrakul N, Mirsaidov I, Shaaban M, Ursulean I, Wambani JS, Zaman A, Ziliukas J, Zontar D, Rehani MM (2009) Radiation exposure to patients during interventional procedures in 20 countries: initial IAEA project results. AJR Am J Roentgenol 193(2):559–569CrossRefPubMed Tsapaki V, Ahmed NA, AlSuwaidi JS, Beganovic A, Benider A, BenOmrane L, Borisova R, Economides S, El-Nachef L, Faj D, Hovhannesyan A, Kharita MH, Khelassi-Toutaoui N, Manatrakul N, Mirsaidov I, Shaaban M, Ursulean I, Wambani JS, Zaman A, Ziliukas J, Zontar D, Rehani MM (2009) Radiation exposure to patients during interventional procedures in 20 countries: initial IAEA project results. AJR Am J Roentgenol 193(2):559–569CrossRefPubMed
21.
go back to reference Rehani MM, Frush DP, Berris T, Einstein AJ (2012) Patient radiation exposure tracking: worldwide programs and needs–results from the first IAEA survey. Eur J Radiol 81(10):968–976CrossRef Rehani MM, Frush DP, Berris T, Einstein AJ (2012) Patient radiation exposure tracking: worldwide programs and needs–results from the first IAEA survey. Eur J Radiol 81(10):968–976CrossRef
22.
go back to reference Thomsen HS, Morcos SK (2003) Contrast media and the kidney: european Society of Urogenital Radiology (ESUR) Guidelines. Br J Radiol 76:513–518CrossRefPubMed Thomsen HS, Morcos SK (2003) Contrast media and the kidney: european Society of Urogenital Radiology (ESUR) Guidelines. Br J Radiol 76:513–518CrossRefPubMed
23.
go back to reference Davidson C, Stacul F, McCullough PA, Tumlin J, Adam A, Lameire N, Becker CR, CIN Consensus Working Panel (2006) Contrast medium use. Am J Cardiol 98(6):42–58CrossRef Davidson C, Stacul F, McCullough PA, Tumlin J, Adam A, Lameire N, Becker CR, CIN Consensus Working Panel (2006) Contrast medium use. Am J Cardiol 98(6):42–58CrossRef
Metadata
Title
Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention
Authors
Shigeru Nakamura
Tomoko Kobayashi
Atsushi Funatsu
Tadahisa Okada
Maria Mauti
Yuki Waizumi
Shinichi Yamada
Publication date
01-05-2016
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 5/2016
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-015-0667-z

Other articles of this Issue 5/2016

Heart and Vessels 5/2016 Go to the issue