Abstract

Objectives

To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE.

Methods

This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn’s. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into “very tolerable,” “moderately tolerable,” and “not tolerable.”

Results

Per patient distension quality was similar between agents (“excellent” or “good” in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as “very tolerable” in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%).

Conclusion

Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.

Key Points

• Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol.
• Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles.
• Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.
Appendix
Available only for authorised users
Literature
1.
go back to reference Taylor SA, Mallett S, Bhatnagar G et al (2018) Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn ’ s disease ( METRIC ): a multicentre trial. Lancet Gastroenterol Hepatol 3:548–558. https://doi.org/10.1016/S2468-1253(18)30161-4 Taylor SA, Mallett S, Bhatnagar G et al (2018) Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn ’ s disease ( METRIC ): a multicentre trial. Lancet Gastroenterol Hepatol 3:548–558. https://​doi.​org/​10.​1016/​S2468-1253(18)30161-4
2.
go back to reference Jesuratnam-Nielsen K, Løgager VB, Rezanavaz-Gheshlagh B, Munkholm P, Thomsen HS (2015) Plain magnetic resonance imaging as an alternative in evaluating inflammation and bowel damage in inflammatory bowel disease - a prospective comparison with conventional magnetic resonance follow-through. Scand J Gastroenterol. https://doi.org/10.3109/00365521.2014.1003398 Jesuratnam-Nielsen K, Løgager VB, Rezanavaz-Gheshlagh B, Munkholm P, Thomsen HS (2015) Plain magnetic resonance imaging as an alternative in evaluating inflammation and bowel damage in inflammatory bowel disease - a prospective comparison with conventional magnetic resonance follow-through. Scand J Gastroenterol. https://​doi.​org/​10.​3109/​00365521.​2014.​1003398
4.
go back to reference Laghi A, Paolantonio P, Iafrate F et al (2003) MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn’s disease. Radiol Med 106:18–27 Laghi A, Paolantonio P, Iafrate F et al (2003) MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn’s disease. Radiol Med 106:18–27
12.
go back to reference Lauenstein TC, Schneemann H, Vogt FM, Herborn CU, Ruhm SG, Debatin JF (2003) Optimization of Oral Contrast Agents for MR Imaging of the Small Bowel 1. Radiology 228:279–283 Lauenstein TC, Schneemann H, Vogt FM, Herborn CU, Ruhm SG, Debatin JF (2003) Optimization of Oral Contrast Agents for MR Imaging of the Small Bowel 1. Radiology 228:279–283
13.
go back to reference Kuehle CA, Ajaj W, Ladd SC, Massing S, Barkhausen J, Lauenstein TC (2006) Hydro-MRI of the small bowel: effect of contrast volume, timing of contrast administration, and data acquisition on bowel distention. AJR Am J Roentgenol 187:W375–W385. https://doi.org/10.2214/AJR.05.1079 Kuehle CA, Ajaj W, Ladd SC, Massing S, Barkhausen J, Lauenstein TC (2006) Hydro-MRI of the small bowel: effect of contrast volume, timing of contrast administration, and data acquisition on bowel distention. AJR Am J Roentgenol 187:W375–W385. https://​doi.​org/​10.​2214/​AJR.​05.​1079
16.
go back to reference Absah I, Bruining DH, Matsumoto JM et al (2012) MR enterography in pediatric inflammatory bowel disease: retrospective assessment of patient tolerance, image quality, and initial performance estimates. AJR Am J Roentgenol 199:367–375. https://doi.org/10.2214/AJR.11.8363 Absah I, Bruining DH, Matsumoto JM et al (2012) MR enterography in pediatric inflammatory bowel disease: retrospective assessment of patient tolerance, image quality, and initial performance estimates. AJR Am J Roentgenol 199:367–375. https://​doi.​org/​10.​2214/​AJR.​11.​8363
17.
go back to reference Gottumukkala RV, LaPointe A, Sargent D, Gee MS (2019) Comparison of three oral contrast preparations for magnetic resonance enterography in pediatric patients with known or suspected Crohn disease: a prospective randomised trial. Pediatr Radiol. https://doi.org/10.1007/s00247-019-04378-5 Gottumukkala RV, LaPointe A, Sargent D, Gee MS (2019) Comparison of three oral contrast preparations for magnetic resonance enterography in pediatric patients with known or suspected Crohn disease: a prospective randomised trial. Pediatr Radiol. https://​doi.​org/​10.​1007/​s00247-019-04378-5
18.
go back to reference Taylor S, Mallett S, Bhatnagar G et al (2014) METRIC (MREnterography or ulTRasound in Crohn’s disease): a study protocol for a multicentre, non-randomised, single-arm, prospective comparison study of magnetic resonance enterography and small bowel ultrasound compared to a reference standard in those. BMC Gastroenterol 14:142. https://doi.org/10.1186/1471-230X-14-142 Taylor S, Mallett S, Bhatnagar G et al (2014) METRIC (MREnterography or ulTRasound in Crohn’s disease): a study protocol for a multicentre, non-randomised, single-arm, prospective comparison study of magnetic resonance enterography and small bowel ultrasound compared to a reference standard in those. BMC Gastroenterol 14:142. https://​doi.​org/​10.​1186/​1471-230X-14-142
19.
go back to reference Taylor SA, Mallett S, Bhatnagar G et al (2019) Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing crohn’s disease patients: the METRIC diagnostic accuracy study. Health Technol Assess 23:vii–161. https://doi.org/10.3310/hta23420 Taylor SA, Mallett S, Bhatnagar G et al (2019) Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing crohn’s disease patients: the METRIC diagnostic accuracy study. Health Technol Assess 23:vii–161. https://​doi.​org/​10.​3310/​hta23420
20.
go back to reference Taylor SA, Halligan S, Goh V et al (2003) Optimizing colonic distention for multi – detector row CT colonography : effect of hyoscine butylbromide and rectal balloon catheter 1. Radiology 229:99–108 Taylor SA, Halligan S, Goh V et al (2003) Optimizing colonic distention for multi – detector row CT colonography : effect of hyoscine butylbromide and rectal balloon catheter 1. Radiology 229:99–108
22.
go back to reference Gwet K (2014) Handbook of inter-rater reliability fourth edition. Gwet K (2014) Handbook of inter-rater reliability fourth edition.
23.
go back to reference Landis J, Koch G (1977) The measurement of observer agreement for categorical data. Biometrics Mar:159–174 Landis J, Koch G (1977) The measurement of observer agreement for categorical data. Biometrics Mar:159–174
Metadata
Title
Influence of oral contrast type and volume on patient experience and quality of luminal distension at MR Enterography in Crohn’s disease: an observational study of patients recruited to the METRIC trial
Authors
Gauraang Bhatnagar
Sue Mallett
Laura Quinn
Rajapandian Ilangovan
Uday Patel
Asif Jaffer
Christopher Pawley
Arun Gupta
Anthony Higginson
Andrew Slater
Damian Tolan
Ian Zealley
Steve Halligan
Stuart A Taylor
on behalf of the METRIC study investigators
Publication date
03-03-2022
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 8/2022
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-022-08614-9

Other articles of this Issue 8/2022

European Radiology 8/2022 Go to the issue