Skip to main content
Top
Published in: European Radiology 11/2020

01-11-2020 | Foreign Body Aspiration | Musculoskeletal

Efficacy and safety of bone marrow aspiration and biopsy using fluoroscopic guidance and a drill-powered needle: clinical experience from 775 cases

Authors: Jeremiah R. Long, J. Derek Stensby, Elizabeth L. Wiesner, Wesley N. Bryson, Travis J. Hillen, Jack W. Jennings

Published in: European Radiology | Issue 11/2020

Login to get access

Abstract

Objectives

To evaluate the efficacy and safety of performing a fluoroscopically guided bone marrow aspiration and biopsy (BMAB) using a drill-powered needle in a large patient population.

Methods

This retrospective study received institutional review board approval with a waiver of patient informed consent. We identified all BMAB procedures from August 2012 through December 2016 performed at our institution using fluoroscopic guidance and a drill-powered needle. Clinical diagnosis, patient age, patient gender, biopsy site, biopsy needle gauge, bone marrow aspirate volume, bone marrow core biopsy length, patient platelet count, conscious sedation details, complications, and diagnostic adequacy were investigated for each case and summarized.

Results

A total of 775 BMAB procedures were performed and analyzed. These were performed in 436 female patients and 339 male patients ranging in age between 16 and 91 years (average age of 53 years). Samples obtained from the procedures in our series were diagnostic in 95.0% of cases. The complication rate for our series was 0.3%.

Conclusions

The use of fluoroscopic guidance and a drill-powered needle for bone marrow aspiration and biopsy is a safe and efficacious procedure.

Key Points

• Fluoroscopy can be utilized for imaging guidance during bone marrow aspiration and biopsy.
• The use of fluoroscopic guidance and a drill-powered needle for bone marrow aspiration and biopsy has a high diagnostic yield.
• The procedure has an excellent patient safety profile.
Literature
2.
3.
go back to reference Moid F, DePalma L (2005) Comparison of relative value of bone marrow aspirates and bone marrow trephine biopsies in the diagnosis of solid tumor metastasis and Hodgkin lymphoma: institutional experience and literature review. Arch Pathol Lab Med 129(4):497PubMed Moid F, DePalma L (2005) Comparison of relative value of bone marrow aspirates and bone marrow trephine biopsies in the diagnosis of solid tumor metastasis and Hodgkin lymphoma: institutional experience and literature review. Arch Pathol Lab Med 129(4):497PubMed
4.
go back to reference Subramanian R, Basu D, Badhe B, Dutta TK (2007) Role of bone marrow trephine biopsy in the diagnosis of marrow involvement in Hodgkin’s disease. Indian J Pathol Microbiol 50(3):640PubMed Subramanian R, Basu D, Badhe B, Dutta TK (2007) Role of bone marrow trephine biopsy in the diagnosis of marrow involvement in Hodgkin’s disease. Indian J Pathol Microbiol 50(3):640PubMed
5.
go back to reference Hamid GA, Hanibala N (2009) Comparison of bone marrow aspiration and bone marrow biopsy in neoplastic disease. Gulf J Oncol (6):41–44 Hamid GA, Hanibala N (2009) Comparison of bone marrow aspiration and bone marrow biopsy in neoplastic disease. Gulf J Oncol (6):41–44
6.
go back to reference Joshi R, Horncastle D, Elderfield K, Lampert I, Rahemtulla A, Naresh KN (2008) Bone marrow trephine combined with immunohistochemistry is superior to bone marrow aspirate in follow-up of myeloma patients. J Clin Pathol 61(2):213–216CrossRef Joshi R, Horncastle D, Elderfield K, Lampert I, Rahemtulla A, Naresh KN (2008) Bone marrow trephine combined with immunohistochemistry is superior to bone marrow aspirate in follow-up of myeloma patients. J Clin Pathol 61(2):213–216CrossRef
7.
go back to reference Lee SH, Erber WN, Porwit A, Tomonaga M, Peterson LC (2008) ICSH guidelines for the standardization of bone marrow specimens and reports. Int J Lab Hematol 30(5):349–364 Lee SH, Erber WN, Porwit A, Tomonaga M, Peterson LC (2008) ICSH guidelines for the standardization of bone marrow specimens and reports. Int J Lab Hematol 30(5):349–364
9.
go back to reference Islam A (1991) A new sternal puncture needle. J Clin Pathol 44(8):690–691CrossRef Islam A (1991) A new sternal puncture needle. J Clin Pathol 44(8):690–691CrossRef
10.
go back to reference Islam A (2007) Bone marrow aspiration before bone marrow core biopsy using the same bone marrow biopsy needle: a good or bad practice? J Clin Pathol 60(2):212–215CrossRef Islam A (2007) Bone marrow aspiration before bone marrow core biopsy using the same bone marrow biopsy needle: a good or bad practice? J Clin Pathol 60(2):212–215CrossRef
11.
go back to reference Konda B, Pathak S, Edwin I et al (2014) Safe and successful bone marrow biopsy: an anatomical and CT-based cadaver study. Am J Hematol 89(10):943–946 Konda B, Pathak S, Edwin I et al (2014) Safe and successful bone marrow biopsy: an anatomical and CT-based cadaver study. Am J Hematol 89(10):943–946
12.
go back to reference Bain BJ (2003) Bone marrow biopsy morbidity and mortality. Br J Heamatol 121(6):949–951CrossRef Bain BJ (2003) Bone marrow biopsy morbidity and mortality. Br J Heamatol 121(6):949–951CrossRef
13.
go back to reference Bain BJ (2006) Morbidity associated with bone marrow aspiration and trephine biopsy - a review of UK data for 2004. Haematologica 91(9):1293–1294 Bain BJ (2006) Morbidity associated with bone marrow aspiration and trephine biopsy - a review of UK data for 2004. Haematologica 91(9):1293–1294
14.
go back to reference Chu F, Tes D, Chan T, Kwong YL (2018) Arterial injury during bone marrow aspiration: embolization through the biopsy needle. J Vasc Interv Radiol 29(4):584CrossRef Chu F, Tes D, Chan T, Kwong YL (2018) Arterial injury during bone marrow aspiration: embolization through the biopsy needle. J Vasc Interv Radiol 29(4):584CrossRef
15.
go back to reference Friedlis MF, Centeno CJ (2016) Performing a better bone marrow aspiration. Phys Med Rehabil Clin N Am 27(4):919–939CrossRef Friedlis MF, Centeno CJ (2016) Performing a better bone marrow aspiration. Phys Med Rehabil Clin N Am 27(4):919–939CrossRef
16.
go back to reference Huang TY, Huang JT, Yam LT, Postel GC, Abaskaron M (1999) Computed tomography guidance in bone marrow aspiration for diagnosis of marrow necrosis and metastasis. J Ky Med Assoc 97(7):299–302PubMed Huang TY, Huang JT, Yam LT, Postel GC, Abaskaron M (1999) Computed tomography guidance in bone marrow aspiration for diagnosis of marrow necrosis and metastasis. J Ky Med Assoc 97(7):299–302PubMed
17.
go back to reference Pfeifer C, Ternes T, St Clari S, Palko W, Dakhil C (2015) Bone marrow aspiration under CT guidance: technique and value. Oncology (Williston Park) 29(4 Suppl 1):205144 Pfeifer C, Ternes T, St Clari S, Palko W, Dakhil C (2015) Bone marrow aspiration under CT guidance: technique and value. Oncology (Williston Park) 29(4 Suppl 1):205144
18.
go back to reference Jain S, Enzerra M, Mehta RS, Smith R, Djokic M (2017) Bone marrow biopsies performed by both the powered OnControl drill device and the Jamshidi needle produce adequate specimens. J Clin Pathol 70(6):541–543 Jain S, Enzerra M, Mehta RS, Smith R, Djokic M (2017) Bone marrow biopsies performed by both the powered OnControl drill device and the Jamshidi needle produce adequate specimens. J Clin Pathol 70(6):541–543
19.
go back to reference Schnapauff D, Marnitz T Freyhardt P et al (2013) CT guided bone biopsy using a battery powered intraosseous device. Cardiovasc Intervent Radiol 36(5):1405–1410 Schnapauff D, Marnitz T Freyhardt P et al (2013) CT guided bone biopsy using a battery powered intraosseous device. Cardiovasc Intervent Radiol 36(5):1405–1410
20.
go back to reference Appel NB, Gilula LA (2001) “Bull’s-eye” modification for transpedicular biopsy and vertebroplasty. AJR Am J Roentgenol 177(6):1387–1389 Appel NB, Gilula LA (2001) “Bull’s-eye” modification for transpedicular biopsy and vertebroplasty. AJR Am J Roentgenol 177(6):1387–1389
22.
go back to reference Vadlamudi V and Sterling K (2017) Fluoroscopically guided powered bone marrow biopsy in interventional radiology: a safe and efficacious procedure. Poster presented at: 42nd Annual Scientific Meeting of Society of Interventional Radiology; 2017; Washington, DC Vadlamudi V and Sterling K (2017) Fluoroscopically guided powered bone marrow biopsy in interventional radiology: a safe and efficacious procedure. Poster presented at: 42nd Annual Scientific Meeting of Society of Interventional Radiology; 2017; Washington, DC
23.
go back to reference Ellis LD, Jensen WN, Westerman MP (1964) Needle biopsy of bone and marrow; an experience with 1,445 biopsies. Arch Intern Med 114:213–221CrossRef Ellis LD, Jensen WN, Westerman MP (1964) Needle biopsy of bone and marrow; an experience with 1,445 biopsies. Arch Intern Med 114:213–221CrossRef
24.
go back to reference Roth J, Newman E (2002) Gluteal compartment syndrome and sciatica after bone marrow biopsy: a case report and review of the literature. Am Surg 68(9):791–794PubMed Roth J, Newman E (2002) Gluteal compartment syndrome and sciatica after bone marrow biopsy: a case report and review of the literature. Am Surg 68(9):791–794PubMed
25.
go back to reference Berber I, Erkurt M, Kuku I et al (2014) An unexpected complication of bone marrow aspiration and trephine biopsy: arteriovenous fistula. Med Princ Pract 23(4):380–383 Berber I, Erkurt M, Kuku I et al (2014) An unexpected complication of bone marrow aspiration and trephine biopsy: arteriovenous fistula. Med Princ Pract 23(4):380–383
26.
go back to reference Khakwani M, Srinath S, Pratt G, Moss P (2019) A rare complication of bone marrow aspiration and trephine biopsy: staphylococcus aureus osteomyelitis and septicaemia. Br J Haematol 184(1):7CrossRef Khakwani M, Srinath S, Pratt G, Moss P (2019) A rare complication of bone marrow aspiration and trephine biopsy: staphylococcus aureus osteomyelitis and septicaemia. Br J Haematol 184(1):7CrossRef
27.
go back to reference Engeset A, Nesheim A, Sokolowski J (1979) Incidence of ‘dry tap’ on bone marrow aspirations in lymphomas and carcinomas. Diagnostic value of the small material in the needle. Scand J Hematol 22(5):417–422CrossRef Engeset A, Nesheim A, Sokolowski J (1979) Incidence of ‘dry tap’ on bone marrow aspirations in lymphomas and carcinomas. Diagnostic value of the small material in the needle. Scand J Hematol 22(5):417–422CrossRef
28.
go back to reference Swerdlow SH, Campo E, Harris NL, Jaffe ES, Pileri SA, Stein H (2008) World Health Organization classification of tumours of haematopoietic and lymphoid tissues, 4th edn. International Agency for Research on Cancer, Lyon Swerdlow SH, Campo E, Harris NL, Jaffe ES, Pileri SA, Stein H (2008) World Health Organization classification of tumours of haematopoietic and lymphoid tissues, 4th edn. International Agency for Research on Cancer, Lyon
29.
go back to reference Dietrich T, Peterson C, Zeimpekis K et al (2019) Fluoroscopy-guided versus CT-guided lumbar steroid injections: comparison of radiation exposure and outcomes. Radiology 290(3):752–759 Dietrich T, Peterson C, Zeimpekis K et al (2019) Fluoroscopy-guided versus CT-guided lumbar steroid injections: comparison of radiation exposure and outcomes. Radiology 290(3):752–759
30.
go back to reference Maino P, Presilla S, Colli Franzone PA, van Kuijk SMJ, Perez RSGM, Koetsier E (2018) Radiation dose exposure for lumbar transforaminal epidural steroid injections and facet joint blocks under CT vs. fluoroscopic guidance. Pain Pract 18(6):798–804 Maino P, Presilla S, Colli Franzone PA, van Kuijk SMJ, Perez RSGM, Koetsier E (2018) Radiation dose exposure for lumbar transforaminal epidural steroid injections and facet joint blocks under CT vs. fluoroscopic guidance. Pain Pract 18(6):798–804
Metadata
Title
Efficacy and safety of bone marrow aspiration and biopsy using fluoroscopic guidance and a drill-powered needle: clinical experience from 775 cases
Authors
Jeremiah R. Long
J. Derek Stensby
Elizabeth L. Wiesner
Wesley N. Bryson
Travis J. Hillen
Jack W. Jennings
Publication date
01-11-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 11/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-06987-3

Other articles of this Issue 11/2020

European Radiology 11/2020 Go to the issue

Imaging Informatics and Artificial Intelligence

Any unique image biomarkers associated with COVID-19?