Skip to main content
Top
Published in: European Radiology 9/2014

01-09-2014 | Gastrointestinal

Liver perfusion in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI): comparison of enhancement in Gd-BT-DO3A and Gd-EOB-DTPA in normal liver parenchyma

Authors: Hanke J. Schalkx, Marijn van Stralen, Kenneth Coenegrachts, Maurice A. A. J. van den Bosch, Charlotte S. van Kessel, Richard van Hillegersberg, Karel J. van Erpecum, Helena M. Verkooijen, Josien P. W. Pluim, Wouter B. Veldhuis, Maarten S. van Leeuwen

Published in: European Radiology | Issue 9/2014

Login to get access

Abstract

Purpose

Within-patient comparison of the enhancement patterns of normal liver parenchyma after gadobutrol and gadoxetate disodium, with emphasis on the start of hepatocytic uptake of gadoxetate disodium.

Materials and methods

Twenty-one patients (12 female, 9 male) without chronic liver disease underwent 1.5-T contrast-enhanced MRI twice, once with an extracellular contrast agent (gadobutrol) and once with a hepatospecific agent (gadoxetate disodium), using a T1-weighted keyhole sequence. Fifteen whole-liver datasets were acquired up to 5 min for both contrast agents and two additional datasets, up to 20 min, for gadoxetate. Signal intensities (SI) of the parenchyma, aorta and portal vein were measured and analysed relative to pre-contrast parenchymal SI.

Results

After gadoxetate, in 29 % of the patients the parenchymal SI decreased by ≥5 % after the initial vascular-phase-induced peak, while in the other 71 % the parenchymal SI remained stable or gradually increased until up to 20 min after the initial peak. The hepatocytic gadoxetate uptake started at a mean of 37.8 s (SD 14.7 s) and not later than 76 s after left ventricle enhancement.

Conclusion

Parenchymal enhancement due to hepatocytic uptake of gadoxetate can start as early as in the late arterial phase. This may confound the assessment of lesion appearance as compared to extracellular contrast such as gadobutrol.

Key Points

Gadoxetate-enhanced liver MRI results in early enhancement of normal parenchyma in patients
The start of the hepatobiliary phase coincides with the late arterial phase
This may confound the assessment of lesion appearance compared to extracellular contrast
Different parenchymal enhancement patterns after gadoxetate were found for normal parenchyma
Literature
1.
go back to reference Feuerlein S, Gupta RT, Boll DT, Merkle EM (2012) Hepatocellular MR contrast agents: enhancement characteristics of liver parenchyma and portal vein after administration of gadoxetic acid in comparison to gadobenate dimeglumine. Eur J Radiol 81(9):2037–2041, Epub 2011/07/02PubMedCrossRef Feuerlein S, Gupta RT, Boll DT, Merkle EM (2012) Hepatocellular MR contrast agents: enhancement characteristics of liver parenchyma and portal vein after administration of gadoxetic acid in comparison to gadobenate dimeglumine. Eur J Radiol 81(9):2037–2041, Epub 2011/07/02PubMedCrossRef
2.
go back to reference Cruite I, Schroeder M, Merkle EM, Sirlin CB (2010) Gadoxetate disodium-enhanced MRI of the liver: part 2, protocol optimization and lesion appearance in the cirrhotic liver. AJR Am J Roentgenol 195(1):29–41, Epub 2010/06/23PubMedCrossRef Cruite I, Schroeder M, Merkle EM, Sirlin CB (2010) Gadoxetate disodium-enhanced MRI of the liver: part 2, protocol optimization and lesion appearance in the cirrhotic liver. AJR Am J Roentgenol 195(1):29–41, Epub 2010/06/23PubMedCrossRef
3.
go back to reference Purysko AS, Remer EM, Veniero JC (2011) Focal liver lesion detection and characterization with GD-EOB-DTPA. Clin Radiol 66(7):673–684, Epub 2011/04/29PubMedCrossRef Purysko AS, Remer EM, Veniero JC (2011) Focal liver lesion detection and characterization with GD-EOB-DTPA. Clin Radiol 66(7):673–684, Epub 2011/04/29PubMedCrossRef
4.
5.
go back to reference Doo KW, Lee CH, Choi JW, Lee J, Kim KA, Park CM (2009) "Pseudo washout" sign in high-flow hepatic hemangioma on gadoxetic acid contrast-enhanced MRI mimicking hypervascular tumor. AJR Am J Roentgenol 193(6):W490–W496, Epub 2009/11/26PubMedCrossRef Doo KW, Lee CH, Choi JW, Lee J, Kim KA, Park CM (2009) "Pseudo washout" sign in high-flow hepatic hemangioma on gadoxetic acid contrast-enhanced MRI mimicking hypervascular tumor. AJR Am J Roentgenol 193(6):W490–W496, Epub 2009/11/26PubMedCrossRef
7.
go back to reference Beck GM, De Becker J, Jones AC, von Falkenhausen M, Willinek WA, Gieseke J (2008) Contrast-enhanced timing robust acquisition order with a preparation of the longitudinal signal component (CENTRA plus) for 3D contrast-enhanced abdominal imaging. J Magn Reson Imaging JMRI 27(6):1461–1467, Epub 2008/05/28CrossRef Beck GM, De Becker J, Jones AC, von Falkenhausen M, Willinek WA, Gieseke J (2008) Contrast-enhanced timing robust acquisition order with a preparation of the longitudinal signal component (CENTRA plus) for 3D contrast-enhanced abdominal imaging. J Magn Reson Imaging JMRI 27(6):1461–1467, Epub 2008/05/28CrossRef
8.
go back to reference Coenegrachts K, Ghekiere J, Denolin V, Gabriele B, Herigault G, Haspeslagh M et al (2010) Perfusion maps of the whole liver based on high temporal and spatial resolution contrast-enhanced MRI (4D THRIVE): feasibility and initial results in focal liver lesions. Eur J Radiol 74(3):529–535, Epub 2009/04/21PubMedCrossRef Coenegrachts K, Ghekiere J, Denolin V, Gabriele B, Herigault G, Haspeslagh M et al (2010) Perfusion maps of the whole liver based on high temporal and spatial resolution contrast-enhanced MRI (4D THRIVE): feasibility and initial results in focal liver lesions. Eur J Radiol 74(3):529–535, Epub 2009/04/21PubMedCrossRef
9.
go back to reference Zizka J, Klzo L, Ferda J, Mrklovsky M, Bukac J (2007) Dynamic and delayed contrast enhancement in upper abdominal MRI studies: comparison of gadoxetic acid and gadobutrol. Eur J Radiol 62(2):186–191, Epub 2007/03/21PubMedCrossRef Zizka J, Klzo L, Ferda J, Mrklovsky M, Bukac J (2007) Dynamic and delayed contrast enhancement in upper abdominal MRI studies: comparison of gadoxetic acid and gadobutrol. Eur J Radiol 62(2):186–191, Epub 2007/03/21PubMedCrossRef
10.
go back to reference Tamada T, Ito K, Sone T, Yamamoto A, Yoshida K, Kakuba K et al (2009) Dynamic contrast-enhanced magnetic resonance imaging of abdominal solid organ and major vessel: comparison of enhancement effect between Gd-EOB-DTPA and Gd-DTPA. J Magn Reson Imaging JMRI 29(3):636–640, Epub 2009/02/27CrossRef Tamada T, Ito K, Sone T, Yamamoto A, Yoshida K, Kakuba K et al (2009) Dynamic contrast-enhanced magnetic resonance imaging of abdominal solid organ and major vessel: comparison of enhancement effect between Gd-EOB-DTPA and Gd-DTPA. J Magn Reson Imaging JMRI 29(3):636–640, Epub 2009/02/27CrossRef
11.
go back to reference Zech CJ, Vos B, Nordell A, Urich M, Blomqvist L, Breuer J et al (2009) Vascular enhancement in early dynamic liver MR imaging in an animal model: comparison of two injection regimen and two different doses Gd-EOB-DTPA (gadoxetic acid) with standard Gd-DTPA. Investig Radiol 44(6):305–310, Epub 2009/05/23CrossRef Zech CJ, Vos B, Nordell A, Urich M, Blomqvist L, Breuer J et al (2009) Vascular enhancement in early dynamic liver MR imaging in an animal model: comparison of two injection regimen and two different doses Gd-EOB-DTPA (gadoxetic acid) with standard Gd-DTPA. Investig Radiol 44(6):305–310, Epub 2009/05/23CrossRef
12.
go back to reference Kuhn JP, Hegenscheid K, Siegmund W, Froehlich CP, Hosten N, Puls R (2009) Normal dynamic MRI enhancement patterns of the upper abdominal organs: gadoxetic acid compared with gadobutrol. AJR Am J Roentgenol 193(5):1318–1323, Epub 2009/10/22PubMedCrossRef Kuhn JP, Hegenscheid K, Siegmund W, Froehlich CP, Hosten N, Puls R (2009) Normal dynamic MRI enhancement patterns of the upper abdominal organs: gadoxetic acid compared with gadobutrol. AJR Am J Roentgenol 193(5):1318–1323, Epub 2009/10/22PubMedCrossRef
13.
go back to reference Reimer P, Rummeny EJ, Daldrup HE, Hesse T, Balzer T, Tombach B et al (1997) Enhancement characteristics of liver metastases, hepatocellular carcinomas, and hemangiomas with Gd-EOB-DTPA: preliminary results with dynamic MR imaging. Eur Radiol 7(2):275–280, Epub 1997/01/01PubMedCrossRef Reimer P, Rummeny EJ, Daldrup HE, Hesse T, Balzer T, Tombach B et al (1997) Enhancement characteristics of liver metastases, hepatocellular carcinomas, and hemangiomas with Gd-EOB-DTPA: preliminary results with dynamic MR imaging. Eur Radiol 7(2):275–280, Epub 1997/01/01PubMedCrossRef
14.
go back to reference Dahlqvist Leinhard O, Dahlstrom N, Kihlberg J, Sandstrom P, Brismar TB, Smedby O et al (2012) Quantifying differences in hepatic uptake of the liver specific contrast agents Gd-EOB-DTPA and Gd-BOPTA: a pilot study. Eur Radiol 22(3):642–653, Epub 2011/10/11PubMedCrossRef Dahlqvist Leinhard O, Dahlstrom N, Kihlberg J, Sandstrom P, Brismar TB, Smedby O et al (2012) Quantifying differences in hepatic uptake of the liver specific contrast agents Gd-EOB-DTPA and Gd-BOPTA: a pilot study. Eur Radiol 22(3):642–653, Epub 2011/10/11PubMedCrossRef
15.
go back to reference Frydrychowicz A, Nagle SK, D'Souza SL, Vigen KK, Reeder SB (2011) Optimized high-resolution contrast-enhanced hepatobiliary imaging at 3 tesla: a cross-over comparison of gadobenate dimeglumine and gadoxetic acid. J Magn Reson Imaging JMRI 34(3):585–594, Epub 2011/07/14CrossRef Frydrychowicz A, Nagle SK, D'Souza SL, Vigen KK, Reeder SB (2011) Optimized high-resolution contrast-enhanced hepatobiliary imaging at 3 tesla: a cross-over comparison of gadobenate dimeglumine and gadoxetic acid. J Magn Reson Imaging JMRI 34(3):585–594, Epub 2011/07/14CrossRef
16.
go back to reference Motosugi U, Ichikawa T, Tominaga L, Sou H, Sano K, Ichikawa S et al (2009) Delay before the hepatocyte phase of Gd-EOB-DTPA-enhanced MR imaging: is it possible to shorten the examination time? Eur Radiol 19(11):2623–2629, Epub 2009/05/28PubMedCrossRef Motosugi U, Ichikawa T, Tominaga L, Sou H, Sano K, Ichikawa S et al (2009) Delay before the hepatocyte phase of Gd-EOB-DTPA-enhanced MR imaging: is it possible to shorten the examination time? Eur Radiol 19(11):2623–2629, Epub 2009/05/28PubMedCrossRef
17.
go back to reference van Kessel CS, Veldhuis WB, van den Bosch MA, van Leeuwen MS (2012) MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation. Eur Radiol 22(10):2153–2160, Epub 2012/05/31PubMedCentralPubMedCrossRef van Kessel CS, Veldhuis WB, van den Bosch MA, van Leeuwen MS (2012) MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation. Eur Radiol 22(10):2153–2160, Epub 2012/05/31PubMedCentralPubMedCrossRef
18.
go back to reference Goshima S, Kanematsu M, Watanabe H, Kondo H, Mizuno N, Kawada H et al (2011) Gadoxetate disodium-enhanced MR imaging: differentiation between early-enhancing non-tumorous lesions and hypervascular hepatocellular carcinomas. Eur J Radiol 79(2):e108–e112, Epub 2011/05/20PubMedCrossRef Goshima S, Kanematsu M, Watanabe H, Kondo H, Mizuno N, Kawada H et al (2011) Gadoxetate disodium-enhanced MR imaging: differentiation between early-enhancing non-tumorous lesions and hypervascular hepatocellular carcinomas. Eur J Radiol 79(2):e108–e112, Epub 2011/05/20PubMedCrossRef
19.
go back to reference Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Investig Radiol 40(11):715–724, Epub 2005/10/19CrossRef Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Investig Radiol 40(11):715–724, Epub 2005/10/19CrossRef
20.
go back to reference Ringe KI, Husarik DB, Sirlin CB, Merkle EM (2010) Gadoxetate disodium-enhanced MRI of the liver: part 1, protocol optimization and lesion appearance in the noncirrhotic liver. AJR Am J Roentgenol 195(1):13–28, Epub 2010/06/23PubMedCrossRef Ringe KI, Husarik DB, Sirlin CB, Merkle EM (2010) Gadoxetate disodium-enhanced MRI of the liver: part 1, protocol optimization and lesion appearance in the noncirrhotic liver. AJR Am J Roentgenol 195(1):13–28, Epub 2010/06/23PubMedCrossRef
21.
go back to reference Lee NK, Kim S, Lee JW, Lee SH, Kang DH, Kim GH et al (2009) Biliary MR imaging with Gd-EOB-DTPA and its clinical applications. Radiographics 29(6):1707–1724, Epub 2009/12/05 Lee NK, Kim S, Lee JW, Lee SH, Kang DH, Kim GH et al (2009) Biliary MR imaging with Gd-EOB-DTPA and its clinical applications. Radiographics 29(6):1707–1724, Epub 2009/12/05
22.
go back to reference Vogl TJ, Kummel S, Hammerstingl R, Schellenbeck M, Schumacher G, Balzer T et al (1996) Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA. Radiology 200(1):59–67, Epub 1996/07/01PubMedCrossRef Vogl TJ, Kummel S, Hammerstingl R, Schellenbeck M, Schumacher G, Balzer T et al (1996) Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA. Radiology 200(1):59–67, Epub 1996/07/01PubMedCrossRef
23.
go back to reference Chung SH, Kim MJ, Choi JY, Hong HS (2010) Comparison of two different injection rates of gadoxetic acid for arterial phase MRI of the liver. J Magn Reson Imaging JMRI 31(2):365–372, Epub 2010/01/26CrossRef Chung SH, Kim MJ, Choi JY, Hong HS (2010) Comparison of two different injection rates of gadoxetic acid for arterial phase MRI of the liver. J Magn Reson Imaging JMRI 31(2):365–372, Epub 2010/01/26CrossRef
24.
go back to reference Tamada T, Ito K, Yoshida K, Kanki A, Higaki A, Tanimoto D et al (2011) Comparison of three different injection methods for arterial phase of Gd-EOB-DTPA enhanced MR imaging of the liver. Eur J Radiol 80(3):e284–e288, Epub 2011/02/08PubMedCrossRef Tamada T, Ito K, Yoshida K, Kanki A, Higaki A, Tanimoto D et al (2011) Comparison of three different injection methods for arterial phase of Gd-EOB-DTPA enhanced MR imaging of the liver. Eur J Radiol 80(3):e284–e288, Epub 2011/02/08PubMedCrossRef
25.
go back to reference Schmid-Tannwald C, Herrmann K, Oto A, Panteleon A, Reiser M, Zech C (2012) Optimization of the dynamic, Gd-EOB-DTPA-enhanced MRI of the liver: the effect of the injection rate. Acta Radiol 53(9):961–965, Epub 2012/10/02PubMedCrossRef Schmid-Tannwald C, Herrmann K, Oto A, Panteleon A, Reiser M, Zech C (2012) Optimization of the dynamic, Gd-EOB-DTPA-enhanced MRI of the liver: the effect of the injection rate. Acta Radiol 53(9):961–965, Epub 2012/10/02PubMedCrossRef
Metadata
Title
Liver perfusion in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI): comparison of enhancement in Gd-BT-DO3A and Gd-EOB-DTPA in normal liver parenchyma
Authors
Hanke J. Schalkx
Marijn van Stralen
Kenneth Coenegrachts
Maurice A. A. J. van den Bosch
Charlotte S. van Kessel
Richard van Hillegersberg
Karel J. van Erpecum
Helena M. Verkooijen
Josien P. W. Pluim
Wouter B. Veldhuis
Maarten S. van Leeuwen
Publication date
01-09-2014
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 9/2014
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3275-x

Other articles of this Issue 9/2014

European Radiology 9/2014 Go to the issue