Skip to main content
Top
Published in: European Radiology 6/2014

01-06-2014 | Magnetic Resonance

Quantitative sodium MR imaging of native versus transplanted kidneys using a dual-tuned proton/sodium (1H/23Na) coil: initial experience

Authors: Chan Hong Moon, Alessandro Furlan, Jung-Hwan Kim, Tiejun Zhao, Ron Shapiro, Kyongtae Ty Bae

Published in: European Radiology | Issue 6/2014

Login to get access

Abstract

Objectives

To compare sodium (23Na) characteristics between native and transplanted kidneys using dual-tuned proton (1H)/sodium MRI.

Methods

Six healthy volunteers and six renal transplant patients (3 normal function, 3 acute allograft rejection) were included. Proton/sodium MRI was obtained at 3 T using a dual-tuned coil. Signal to noise ratio (SNR), sodium concentration ([23Na]) and cortico-medullary sodium gradient (CMSG) were measured. Reproducibility of [23Na] measurement was also tested. SNR, [23Na] and CMSG of the native and transplanted kidneys were compared.

Results

Proton and sodium images of kidneys were successfully acquired. SNR and [23Na] measurements of the native kidneys were reproducible at two different sessions. [23Na] and CMSG of the transplanted kidneys was significantly lower than those of the native kidneys: 153.5 ± 11.9 vs. 192.9 ± 9.6 mM (P = 0.002) and 8.9 ± 1.5 vs. 10.5 ± 0.9 mM/mm (P = 0.041), respectively. [23Na] and CMSG of the transplanted kidneys with normal function vs. acute rejection were not statistically different.

Conclusions

Sodium quantification of kidneys was reliably performed using proton/sodium MRI. [23Na] and CMSG of the transplanted kidneys were lower than those of the native kidneys, but without a statistically significant difference between patients with or without renal allograft rejection.

Key Points

Dual-tuned proton/sodium RF coil enables co-registered proton and sodium MRI.
Structural and sodium biochemical property can be acquired by dual-tuned proton/sodium MRI.
Sodium and sodium gradient of kidneys can be measured by dual-tuned MRI.
Sodium concentration was lower in transplanted kidneys than in native kidneys.
Sodium gradient of transplanted kidneys was lower than for native kidneys.
Appendix
Available only for authorised users
Literature
1.
go back to reference Chandarana H, Lee VS (2009) Renal functional MRI: are we ready for clinical application? Am J Roentgenol 192:1550–1557CrossRef Chandarana H, Lee VS (2009) Renal functional MRI: are we ready for clinical application? Am J Roentgenol 192:1550–1557CrossRef
2.
go back to reference Jamison R, Kriz W (1982) Urinary concentrating mechanism, structure and function. Oxford University Press, New York Jamison R, Kriz W (1982) Urinary concentrating mechanism, structure and function. Oxford University Press, New York
3.
4.
go back to reference Haneder S, Juras V, Michaely H et al (2013) In vivo sodium (23Na) imaging of the human kidneys at 7T: preliminary results. Eur Radiol 24:494–501PubMedCrossRef Haneder S, Juras V, Michaely H et al (2013) In vivo sodium (23Na) imaging of the human kidneys at 7T: preliminary results. Eur Radiol 24:494–501PubMedCrossRef
5.
go back to reference Haneder S, Kettnaker P, Konstandin S et al (2013) Quantitative in vivo 23Na MR imaging of the healthy human kidney: determination of physiological ranges at 3.0T with comparison to DWI and BOLD. MAGMA 26:501–509PubMedCrossRef Haneder S, Kettnaker P, Konstandin S et al (2013) Quantitative in vivo 23Na MR imaging of the healthy human kidney: determination of physiological ranges at 3.0T with comparison to DWI and BOLD. MAGMA 26:501–509PubMedCrossRef
6.
go back to reference Haneder S, Konstandin S, Morelli J et al (2011) Quantitative and qualitative (23)Na MR imaging of the human kidneys at 3T: before and after a water load. Radiology 260:857–865PubMedCrossRef Haneder S, Konstandin S, Morelli J et al (2011) Quantitative and qualitative (23)Na MR imaging of the human kidneys at 3T: before and after a water load. Radiology 260:857–865PubMedCrossRef
7.
go back to reference Haneder S, Michaely H, Konstandin S et al (2014) 3T renal (23)Na-MRI: effects of desmopressin in patients with central diabetes insipidus. MAGMA 27:47–52 Haneder S, Michaely H, Konstandin S et al (2014) 3T renal (23)Na-MRI: effects of desmopressin in patients with central diabetes insipidus. MAGMA 27:47–52
8.
go back to reference Maril N, Margalit R, Mispelter J, Degani H (2004) Functional sodium magnetic resonance imaging of the intact rat kidney. Kidney Int 65:927–935PubMedCrossRef Maril N, Margalit R, Mispelter J, Degani H (2004) Functional sodium magnetic resonance imaging of the intact rat kidney. Kidney Int 65:927–935PubMedCrossRef
9.
go back to reference Maril N, Margalit R, Mispelter J, Degani H (2005) Sodium magnetic resonance imaging of diuresis: spatial and kinetic response. Magn Reson Med 53:545–552PubMedCrossRef Maril N, Margalit R, Mispelter J, Degani H (2005) Sodium magnetic resonance imaging of diuresis: spatial and kinetic response. Magn Reson Med 53:545–552PubMedCrossRef
10.
go back to reference Maril N, Margalit R, Rosen S, Heyman SN, Degani H (2006) Detection of evolving acute tubular necrosis with renal 23Na MRI: studies in rats. Kidney Int 69:765–768PubMedCrossRef Maril N, Margalit R, Rosen S, Heyman SN, Degani H (2006) Detection of evolving acute tubular necrosis with renal 23Na MRI: studies in rats. Kidney Int 69:765–768PubMedCrossRef
11.
go back to reference Maril N, Rosen Y, Reynolds GH, Ivanishev A, Ngo L, Lenkinski RE (2006) Sodium MRI of the human kidney at 3 tesla. Magn Reson Med 56:1229–1234PubMedCrossRef Maril N, Rosen Y, Reynolds GH, Ivanishev A, Ngo L, Lenkinski RE (2006) Sodium MRI of the human kidney at 3 tesla. Magn Reson Med 56:1229–1234PubMedCrossRef
12.
go back to reference Kalayciyan R, Wetterling F, Neudecker S, Haneder S, Gretz N, Schad L (2013) Bilateral kidney sodium-MRI: enabling accurate quantification of renal sodium concentration through a two-element phased array system. J Magn Res Imaging 38:564–572CrossRef Kalayciyan R, Wetterling F, Neudecker S, Haneder S, Gretz N, Schad L (2013) Bilateral kidney sodium-MRI: enabling accurate quantification of renal sodium concentration through a two-element phased array system. J Magn Res Imaging 38:564–572CrossRef
13.
14.
go back to reference Atthe B, Babsky A, Hopewell P, Phillips C, Molitoris B, Bansal N (2009) Early monitoring of acute tubular necrosis in the rat kidney by 23Na-MRI. Am J Physiol Ren Physiol 297:F1288–F1298CrossRef Atthe B, Babsky A, Hopewell P, Phillips C, Molitoris B, Bansal N (2009) Early monitoring of acute tubular necrosis in the rat kidney by 23Na-MRI. Am J Physiol Ren Physiol 297:F1288–F1298CrossRef
15.
go back to reference Neuberger T, Gulani V, Webb A (2007) Sodium renal imaging in mice at high magnetic fields. Magn Reson Med 58:1067–1071PubMedCrossRef Neuberger T, Gulani V, Webb A (2007) Sodium renal imaging in mice at high magnetic fields. Magn Reson Med 58:1067–1071PubMedCrossRef
16.
go back to reference Moon CH, Furlan A, Kim J-H, Jacobs L, Zhao T, Bae KT (2011) In vivo sodium MR imaging of rabbit kidney using dual-tuned RF coil at 3T. Proc Int Soc Magn Reson Med 19:2946 Moon CH, Furlan A, Kim J-H, Jacobs L, Zhao T, Bae KT (2011) In vivo sodium MR imaging of rabbit kidney using dual-tuned RF coil at 3T. Proc Int Soc Magn Reson Med 19:2946
17.
go back to reference Shapiro EM, Borthakur A, Gougoutas A, Reddy R (2002) 23Na MRI accurately measures fixed charge density in articular cartilage. Magn Reson Med 47:284–291PubMedCentralPubMedCrossRef Shapiro EM, Borthakur A, Gougoutas A, Reddy R (2002) 23Na MRI accurately measures fixed charge density in articular cartilage. Magn Reson Med 47:284–291PubMedCentralPubMedCrossRef
18.
go back to reference Moon CH, Kim J-H, Zhao T (2013) Quantitative 23Na MRI of human knee cartilage using dual‐tuned 1H/23Na transceiver array radiofrequency coil at 7 tesla. J Magn Reson Imaging 38:1063–1072PubMedCrossRef Moon CH, Kim J-H, Zhao T (2013) Quantitative 23Na MRI of human knee cartilage using dual‐tuned 1H/23Na transceiver array radiofrequency coil at 7 tesla. J Magn Reson Imaging 38:1063–1072PubMedCrossRef
19.
go back to reference Kim J-H, Moon CH, Park B-W, Furlan A, Zhao T, Bae K (2012) Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3T. Magn Reson Imaging 30:562–571PubMedCrossRef Kim J-H, Moon CH, Park B-W, Furlan A, Zhao T, Bae K (2012) Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3T. Magn Reson Imaging 30:562–571PubMedCrossRef
20.
go back to reference Moon CH, Jacobs L, Kim JH et al (2012) Part 2: quantitative proton T2 and sodium magnetic resonance imaging to assess intervertebral disc degeneration in a rabbit model. Spine 37:E1113–E1119PubMedCentralPubMedCrossRef Moon CH, Jacobs L, Kim JH et al (2012) Part 2: quantitative proton T2 and sodium magnetic resonance imaging to assess intervertebral disc degeneration in a rabbit model. Spine 37:E1113–E1119PubMedCentralPubMedCrossRef
21.
go back to reference Moon CH, Kim JH, Jacobs L et al (2012) Part 1: dual-tuned proton/sodium magnetic resonance imaging of the lumbar spine in a rabbit model. Spine 37:E1106–E1112PubMedCentralPubMedCrossRef Moon CH, Kim JH, Jacobs L et al (2012) Part 1: dual-tuned proton/sodium magnetic resonance imaging of the lumbar spine in a rabbit model. Spine 37:E1106–E1112PubMedCentralPubMedCrossRef
22.
go back to reference Boada FE, Gillen JS, Shen GX, Chang SY, Thulborn KR (1997) Fast three dimensional sodium imaging. Magn Reson Med 37:706–715PubMedCrossRef Boada FE, Gillen JS, Shen GX, Chang SY, Thulborn KR (1997) Fast three dimensional sodium imaging. Magn Reson Med 37:706–715PubMedCrossRef
23.
go back to reference Jerecic R, Bock M, Nielles-Vallespin S, Wacker C, Bauer W, Schad LR (2004) ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times. MAGMA 16:297–302PubMedCrossRef Jerecic R, Bock M, Nielles-Vallespin S, Wacker C, Bauer W, Schad LR (2004) ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times. MAGMA 16:297–302PubMedCrossRef
24.
go back to reference Nielles-Vallespin S, Weber MA, Bock M et al (2007) 3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle. Magn Reson Med 57:74–81PubMedCrossRef Nielles-Vallespin S, Weber MA, Bock M et al (2007) 3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle. Magn Reson Med 57:74–81PubMedCrossRef
25.
go back to reference Staroswiecki E, Bangerter NK, Gurney PT, Grafendorfer T, Gold GE, Hargreaves BA (2010) In vivo sodium imaging of human patellar cartilage with a 3D cones sequence at 3T and 7T. J Magn Reson Imaging 32:446–451PubMedCentralPubMedCrossRef Staroswiecki E, Bangerter NK, Gurney PT, Grafendorfer T, Gold GE, Hargreaves BA (2010) In vivo sodium imaging of human patellar cartilage with a 3D cones sequence at 3T and 7T. J Magn Reson Imaging 32:446–451PubMedCentralPubMedCrossRef
26.
go back to reference Zhao T, Qian Y, Hue Y, Ibrahim T, Boad F (2009) Implementation of a 3D isotropic ultra-short TE (UTE) sequence. Proc Int Soc Magn Reson Med 17:2662 Zhao T, Qian Y, Hue Y, Ibrahim T, Boad F (2009) Implementation of a 3D isotropic ultra-short TE (UTE) sequence. Proc Int Soc Magn Reson Med 17:2662
27.
go back to reference Sadowski EA, Fain SB, Alford SK et al (2005) Assessment of acute renal transplant rejection with blood oxygen level–dependent MR imaging: initial experience. Radiology 236:911–919PubMedCrossRef Sadowski EA, Fain SB, Alford SK et al (2005) Assessment of acute renal transplant rejection with blood oxygen level–dependent MR imaging: initial experience. Radiology 236:911–919PubMedCrossRef
28.
go back to reference Thoeny HC, Zumstein D, Simon-Zoula S et al (2006) Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. Radiology 241:812–821PubMedCrossRef Thoeny HC, Zumstein D, Simon-Zoula S et al (2006) Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. Radiology 241:812–821PubMedCrossRef
29.
go back to reference Chang G, Madelin G, Sherman O et al (2012) Improved assessment of cartilage repair tissue using fluid-suppressed 23Na inversion recovery MRI at 7 Tesla: preliminary results. Eur Radiol 22:1341–1349PubMedCentralPubMedCrossRef Chang G, Madelin G, Sherman O et al (2012) Improved assessment of cartilage repair tissue using fluid-suppressed 23Na inversion recovery MRI at 7 Tesla: preliminary results. Eur Radiol 22:1341–1349PubMedCentralPubMedCrossRef
Metadata
Title
Quantitative sodium MR imaging of native versus transplanted kidneys using a dual-tuned proton/sodium (1H/23Na) coil: initial experience
Authors
Chan Hong Moon
Alessandro Furlan
Jung-Hwan Kim
Tiejun Zhao
Ron Shapiro
Kyongtae Ty Bae
Publication date
01-06-2014
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 6/2014
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3138-5

Other articles of this Issue 6/2014

European Radiology 6/2014 Go to the issue