Skip to main content
Top
Published in: European Radiology 6/2013

01-06-2013 | Breast

Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography

Authors: Ji Hyun Youk, Hye Mi Gweon, Eun Ju Son, Jin Chung, Jeong-Ah Kim, Eun-kyung Kim

Published in: European Radiology | Issue 6/2013

Login to get access

Abstract

Objectives

To evaluate the interobserver agreement and the diagnostic performance of 3D shear-wave elastography (SWE) for breast lesions in comparison with 2D SWE.

Methods

A total of 163 breast lesions (malignant 48, benign 115) in 146 women who underwent B-mode ultrasound and SWE before biopsy were included. Two radiologists reviewed six data sets (B-mode, SWE, and a combination of both for 2D and 3D ultrasound). B-mode and SWE features were recorded. BI-RADS category was assigned for B-mode and combined sets. Interobserver variability was assessed using the κ statistic. Diagnostic performance of each data set was evaluated using the area under the ROC curve (AUC).

Results

SWE showed substantial to almost perfect agreement, with Ehomo in 2D SWE being higher than in 3D SWE. The AUC of 2D SWE was higher than 3D SWE for all SWE features, significantly so for Ecol (0.933 vs. 0.867, P = 0.002) and Emax (0.961 vs. 0.874, P = 0.006). After adding SWE to B-mode ultrasound, the AUC in 2D ultrasound increased significantly (0.968 vs. 0.912, P = 0.008), but 3D ultrasound showed no significant difference (0.966 vs. 0.935; P = 0.07).

Conclusion

For 3D SWE, interobserver agreement was good, but the diagnostic performance was inferior to 2D SWE even after adding to B-mode ultrasound.

Key Points

Shear-wave elastography (SWE) provides further diagnostic information during breast ultrasound.
3D SWE diagnostic performance is inferior to 2D SWE.
In 3D SWE, interobserver agreement was good.
2D B-mode ultrasound showed significant diagnostic improvement when combined with 2D SWE.
3D B-mode ultrasound performance was not significantly improved when combined with 3D SWE.
Literature
1.
go back to reference American College of Radiology (2003) Breast imaging reporting and data system-ultrasound, 1st end. American College of Radiology, Reston American College of Radiology (2003) Breast imaging reporting and data system-ultrasound, 1st end. American College of Radiology, Reston
2.
go back to reference Kim EK, Ko KH, Oh KK, Kwak JY, You JK, Kim MJ, Park BW (2008) Clinical application of the BI-RADS final assessment to breast sonography in conjunction with mammography. AJR Am J Roentgenol 190:1209–1215PubMedCrossRef Kim EK, Ko KH, Oh KK, Kwak JY, You JK, Kim MJ, Park BW (2008) Clinical application of the BI-RADS final assessment to breast sonography in conjunction with mammography. AJR Am J Roentgenol 190:1209–1215PubMedCrossRef
3.
go back to reference Chen D-R, Lai H-W (2011) Three-dimensional ultrasonography for breast malignancy detection. Expert Opin Med Diagn 5:253–261PubMedCrossRef Chen D-R, Lai H-W (2011) Three-dimensional ultrasonography for breast malignancy detection. Expert Opin Med Diagn 5:253–261PubMedCrossRef
4.
go back to reference Gordon PB (2002) Ultrasound for breast cancer screening and staging. Radiol Clin North Am 40:431–441PubMedCrossRef Gordon PB (2002) Ultrasound for breast cancer screening and staging. Radiol Clin North Am 40:431–441PubMedCrossRef
5.
go back to reference Cho N, Moon WK, Cha JH, Kim SM, Han BK, Kim EK, Kim MH, Chung SY, Choi HY, Im JG (2006) Differentiating benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional US. Radiology 240:26–32PubMedCrossRef Cho N, Moon WK, Cha JH, Kim SM, Han BK, Kim EK, Kim MH, Chung SY, Choi HY, Im JG (2006) Differentiating benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional US. Radiology 240:26–32PubMedCrossRef
6.
go back to reference Cho KR, Seo BK, Lee JY, Pisano ED, Je BK, Choi EJ, Chung KB, Whan Oh Y (2005) A comparative study of 2D and 3D ultrasonography for evaluation of solid breast masses. Eur J Radiol 54:365–370PubMedCrossRef Cho KR, Seo BK, Lee JY, Pisano ED, Je BK, Choi EJ, Chung KB, Whan Oh Y (2005) A comparative study of 2D and 3D ultrasonography for evaluation of solid breast masses. Eur J Radiol 54:365–370PubMedCrossRef
7.
go back to reference Gong X, Xu Q, Xu Z, Xiong P, Yan W, Chen Y (2011) Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysis. Breast Cancer Res Treat 130:11–18PubMedCrossRef Gong X, Xu Q, Xu Z, Xiong P, Yan W, Chen Y (2011) Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysis. Breast Cancer Res Treat 130:11–18PubMedCrossRef
8.
go back to reference Sadigh G, Carlos RC, Neal CH, Dwamena BA (2012) Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoring. Breast Cancer Res Treat 133:23–35PubMedCrossRef Sadigh G, Carlos RC, Neal CH, Dwamena BA (2012) Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoring. Breast Cancer Res Treat 133:23–35PubMedCrossRef
9.
go back to reference Sadigh G, Carlos RC, Neal CH, Dwamena BA (2012) Accuracy of quantitative ultrasound elastography for differentiation of malignant and benign breast abnormalities: a meta-analysis. Breast Cancer Res Treat 134:923–931PubMedCrossRef Sadigh G, Carlos RC, Neal CH, Dwamena BA (2012) Accuracy of quantitative ultrasound elastography for differentiation of malignant and benign breast abnormalities: a meta-analysis. Breast Cancer Res Treat 134:923–931PubMedCrossRef
10.
go back to reference Tanter M, Bercoff J, Athanasiou A, Deffieux T, Gennisson JL, Montaldo G, Muller M, Tardivon A, Fink M (2008) Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging. Ultrasound Med Biol 34:1373–1386PubMedCrossRef Tanter M, Bercoff J, Athanasiou A, Deffieux T, Gennisson JL, Montaldo G, Muller M, Tardivon A, Fink M (2008) Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging. Ultrasound Med Biol 34:1373–1386PubMedCrossRef
11.
go back to reference Comstock C (2011) Ultrasound elastography of breast lesions. Ultrasound Clin 6:407–415CrossRef Comstock C (2011) Ultrasound elastography of breast lesions. Ultrasound Clin 6:407–415CrossRef
12.
go back to reference Athanasiou A, Tardivon A, Tanter M, Sigal-Zafrani B, Bercoff J, Deffieux T, Gennisson JL, Fink M, Neuenschwander S (2010) Breast lesions: quantitative elastography with supersonic shear imaging–preliminary results. Radiology 256:297–303PubMedCrossRef Athanasiou A, Tardivon A, Tanter M, Sigal-Zafrani B, Bercoff J, Deffieux T, Gennisson JL, Fink M, Neuenschwander S (2010) Breast lesions: quantitative elastography with supersonic shear imaging–preliminary results. Radiology 256:297–303PubMedCrossRef
13.
go back to reference Evans A, Whelehan P, Thomson K, McLean D, Brauer K, Purdie C, Jordan L, Baker L, Thompson A (2010) Quantitative shear wave ultrasound elastography: initial experience in solid breast masses. Breast Cancer Res 12:R104PubMedCrossRef Evans A, Whelehan P, Thomson K, McLean D, Brauer K, Purdie C, Jordan L, Baker L, Thompson A (2010) Quantitative shear wave ultrasound elastography: initial experience in solid breast masses. Breast Cancer Res 12:R104PubMedCrossRef
14.
go back to reference Tozaki M, Fukuma E (2011) Pattern classification of ShearWave elastography images for differential diagnosis between benign and malignant solid breast masses. Acta Radiol 52:1069–1075PubMedCrossRef Tozaki M, Fukuma E (2011) Pattern classification of ShearWave elastography images for differential diagnosis between benign and malignant solid breast masses. Acta Radiol 52:1069–1075PubMedCrossRef
15.
go back to reference Chang JM, Moon WK, Cho N, Yi A, Koo HR, Han W, Noh DY, Moon HG, Kim SJ (2011) Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases. Breast Cancer Res Treat 129:89–97PubMedCrossRef Chang JM, Moon WK, Cho N, Yi A, Koo HR, Han W, Noh DY, Moon HG, Kim SJ (2011) Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases. Breast Cancer Res Treat 129:89–97PubMedCrossRef
16.
go back to reference Berg WA, Cosgrove DO, Dore CJ, Schafer FK, Svensson WE, Hooley RJ, Ohlinger R, Mendelson EB, Balu-Maestro C, Locatelli M, Tourasse C, Cavanaugh BC, Juhan V, Stavros AT, Tardivon A, Gay J, Henry JP, Cohen-Bacrie C (2012) Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Radiology 262:435–449PubMedCrossRef Berg WA, Cosgrove DO, Dore CJ, Schafer FK, Svensson WE, Hooley RJ, Ohlinger R, Mendelson EB, Balu-Maestro C, Locatelli M, Tourasse C, Cavanaugh BC, Juhan V, Stavros AT, Tardivon A, Gay J, Henry JP, Cohen-Bacrie C (2012) Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Radiology 262:435–449PubMedCrossRef
17.
go back to reference McDonald DN (2011) 3-dimensional breast ultrasonography: what have we been missing? Ultrasound clin 6:381–406CrossRef McDonald DN (2011) 3-dimensional breast ultrasonography: what have we been missing? Ultrasound clin 6:381–406CrossRef
18.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
19.
go back to reference Lazarus E, Mainiero MB, Schepps B, Koelliker SL, Livingston LS (2006) BI-RADS lexicon for US and mammography: interobserver variability and positive predictive value. Radiology 239:385–391PubMedCrossRef Lazarus E, Mainiero MB, Schepps B, Koelliker SL, Livingston LS (2006) BI-RADS lexicon for US and mammography: interobserver variability and positive predictive value. Radiology 239:385–391PubMedCrossRef
20.
go back to reference Berg WA, Blume JD, Cormack JB, Mendelson EB (2006) Operator dependence of physician-performed whole-breast US: lesion detection and characterization. Radiology 241:355–365PubMedCrossRef Berg WA, Blume JD, Cormack JB, Mendelson EB (2006) Operator dependence of physician-performed whole-breast US: lesion detection and characterization. Radiology 241:355–365PubMedCrossRef
21.
go back to reference Abdullah N, Mesurolle B, El-Khoury M, Kao E (2009) Breast imaging reporting and data system lexicon for US: interobserver agreement for assessment of breast masses. Radiology 252:665–672PubMedCrossRef Abdullah N, Mesurolle B, El-Khoury M, Kao E (2009) Breast imaging reporting and data system lexicon for US: interobserver agreement for assessment of breast masses. Radiology 252:665–672PubMedCrossRef
22.
go back to reference Lee HJ, Kim EK, Kim MJ, Youk JH, Lee JY, Kang DR, Oh KK (2008) Observer variability of breast imaging reporting and data system (BI-RADS) for breast ultrasound. Eur J Radiol 65:293–298PubMedCrossRef Lee HJ, Kim EK, Kim MJ, Youk JH, Lee JY, Kang DR, Oh KK (2008) Observer variability of breast imaging reporting and data system (BI-RADS) for breast ultrasound. Eur J Radiol 65:293–298PubMedCrossRef
23.
go back to reference Park CS, Lee JH, Yim HW, Kang BJ, Kim HS, Jung JI, Jung NY, Kim SH (2007) Observer agreement using the ACR breast imaging reporting and data system (BI-RADS)-ultrasound, first edition (2003). Korean J Radiol 8:397–402PubMedCrossRef Park CS, Lee JH, Yim HW, Kang BJ, Kim HS, Jung JI, Jung NY, Kim SH (2007) Observer agreement using the ACR breast imaging reporting and data system (BI-RADS)-ultrasound, first edition (2003). Korean J Radiol 8:397–402PubMedCrossRef
24.
go back to reference Cosgrove DO, Berg WA, Dore CJ, Skyba DM, Henry JP, Gay J, Cohen-Bacrie C (2012) Shear wave elastography for breast masses is highly reproducible. Eur Radiol 22:1023–1032PubMedCrossRef Cosgrove DO, Berg WA, Dore CJ, Skyba DM, Henry JP, Gay J, Cohen-Bacrie C (2012) Shear wave elastography for breast masses is highly reproducible. Eur Radiol 22:1023–1032PubMedCrossRef
25.
go back to reference Shin HJ, Kim HH, Cha JH, Park JH, Lee KE, Kim JH (2011) Automated ultrasound of the breast for diagnosis: interobserver agreement on lesion detection and characterization. AJR Am J Roentgenol 197:747–754PubMedCrossRef Shin HJ, Kim HH, Cha JH, Park JH, Lee KE, Kim JH (2011) Automated ultrasound of the breast for diagnosis: interobserver agreement on lesion detection and characterization. AJR Am J Roentgenol 197:747–754PubMedCrossRef
26.
go back to reference Zhang J, Lai XJ, Zhu QL, Wang HY, Jiang YX, Liu H, Dai Q, You SS, Xiao MS, Sun Q (2012) Interobserver agreement for sonograms of breast lesions obtained by an automated breast volume scanner. Eur J Radiol 81:2179–2183PubMedCrossRef Zhang J, Lai XJ, Zhu QL, Wang HY, Jiang YX, Liu H, Dai Q, You SS, Xiao MS, Sun Q (2012) Interobserver agreement for sonograms of breast lesions obtained by an automated breast volume scanner. Eur J Radiol 81:2179–2183PubMedCrossRef
27.
go back to reference Yoon JH, Kim MH, Kim EK, Moon HJ, Kwak JY, Kim MJ (2011) Interobserver variability of ultrasound elastography: how it affects the diagnosis of breast lesions. AJR Am J Roentgenol 196:730–736PubMedCrossRef Yoon JH, Kim MH, Kim EK, Moon HJ, Kwak JY, Kim MJ (2011) Interobserver variability of ultrasound elastography: how it affects the diagnosis of breast lesions. AJR Am J Roentgenol 196:730–736PubMedCrossRef
28.
go back to reference Watermann DO, Foldi M, Hanjalic-Beck A, Hasenburg A, Lughausen A, Prompeler H, Gitsch G, Stickeler E (2005) Three-dimensional ultrasound for the assessment of breast lesions. Ultrasound Obstet Gynecol 25:592–598PubMedCrossRef Watermann DO, Foldi M, Hanjalic-Beck A, Hasenburg A, Lughausen A, Prompeler H, Gitsch G, Stickeler E (2005) Three-dimensional ultrasound for the assessment of breast lesions. Ultrasound Obstet Gynecol 25:592–598PubMedCrossRef
29.
go back to reference Youk JH, Jung I, Kim EK, Kim MJ, Son EJ, Moon HJ, Kwak JY (2012) US follow-up protocol in concordant benign result after US-guided 14-gauge core needle breast biopsy. Breast Cancer Res Treat 132:1089–1097PubMedCrossRef Youk JH, Jung I, Kim EK, Kim MJ, Son EJ, Moon HJ, Kwak JY (2012) US follow-up protocol in concordant benign result after US-guided 14-gauge core needle breast biopsy. Breast Cancer Res Treat 132:1089–1097PubMedCrossRef
Metadata
Title
Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
Authors
Ji Hyun Youk
Hye Mi Gweon
Eun Ju Son
Jin Chung
Jeong-Ah Kim
Eun-kyung Kim
Publication date
01-06-2013
Publisher
Springer-Verlag
Published in
European Radiology / Issue 6/2013
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2736-3

Other articles of this Issue 6/2013