Aims

To compare in vivo DNA lesions induced during helical and sequential coronary computed tomography angiography (CTA) and to evaluate the effect of CT parameters on double-strand break (DSB) levels.

Methods

Thirty-six patients were examined with various CT protocols and modes (helical scan, n = 27; sequential scan, n = 9) either using a 64-slice dual-source or a 128-slice CT system. Blood samples were obtained before and 30 min after CT. Lymphocytes were isolated, stained against the phosphorylated histone variant γ-H2AX, and DSBs were visualised by using fluorescence microscopy.

Results

DSB yields 30 min after CTA ranged from 0.04 to 0.71 per cell and showed a significant correlation to DLP (ρ = 0.81, p < 0.00001). Median DSB yield and median DLP were significantly lower after sequential compared to helical CT examinations (0.11 vs. 0.37 DSBs/cell and 249 vs. 958 mGy cm, p < 0.00001). Additional calcium scoring led to an increase in DLP (p = 0.15) and DSB levels (p = 0.04). DSB levels normalised to the DLP showed a significant correlation to the attenuation of the blood (ρ = 0.53, p = 0.01) and a negative correlation to the body mass index of the patients (ρ = −0.37, p = 0.06).

Conclusion

γ-H2AX immunofluorescence microscopy allows one to determine dose-related effects on x-ray-induced DSB levels and to consider individual factors which cannot be monitored by physical dose measurements.
Literature
1.
go back to reference Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500–507CrossRefPubMed Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500–507CrossRefPubMed
2.
go back to reference Paul JF, Abada HT (2007) Strategies for reduction of radiation dose in cardiac multislice CT. Eur Radiol 17:2028–2037CrossRefPubMed Paul JF, Abada HT (2007) Strategies for reduction of radiation dose in cardiac multislice CT. Eur Radiol 17:2028–2037CrossRefPubMed
3.
go back to reference Achenbach S, Anders K, Kalender WA (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198CrossRefPubMed Achenbach S, Anders K, Kalender WA (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198CrossRefPubMed
4.
go back to reference Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305–1310CrossRefPubMed Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305–1310CrossRefPubMed
5.
go back to reference Leschka S, Scheffel H, Desbiolles L et al (2007) Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42:543–549CrossRefPubMed Leschka S, Scheffel H, Desbiolles L et al (2007) Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42:543–549CrossRefPubMed
6.
go back to reference Herzog BA, Husmann L, Burkhard N et al (2008) Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 29:3037–3042CrossRefPubMed Herzog BA, Husmann L, Burkhard N et al (2008) Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 29:3037–3042CrossRefPubMed
7.
go back to reference Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249:71–80CrossRefPubMed Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249:71–80CrossRefPubMed
8.
go back to reference Earls JP, Berman EL, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753CrossRefPubMed Earls JP, Berman EL, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753CrossRefPubMed
9.
go back to reference Hausleiter J, Meyer T (2008) Tips to minimize radiation exposure. J Cardiovasc Comput Tomogr 2:325–327CrossRefPubMed Hausleiter J, Meyer T (2008) Tips to minimize radiation exposure. J Cardiovasc Comput Tomogr 2:325–327CrossRefPubMed
10.
go back to reference Deak P, van Straten M, Shrimpton PC, Zankl M, Kalender WA (2008) Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography. Eur Radiol 18:759–772CrossRefPubMed Deak P, van Straten M, Shrimpton PC, Zankl M, Kalender WA (2008) Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography. Eur Radiol 18:759–772CrossRefPubMed
11.
go back to reference Kalender WA, Schmidt B, Zankl M, Schmidt M (1999) A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 9:555–562CrossRefPubMed Kalender WA, Schmidt B, Zankl M, Schmidt M (1999) A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 9:555–562CrossRefPubMed
12.
go back to reference Bauchinger M (1995) Quantification of low-level radiation exposure by conventional chromosome aberration analysis. Mutat Res 339:177–189PubMed Bauchinger M (1995) Quantification of low-level radiation exposure by conventional chromosome aberration analysis. Mutat Res 339:177–189PubMed
13.
go back to reference Edwards AA, Lindholm C, Darroudi F et al (2005) Review of translocations detected by FISH for retrospective biological dosimetry applications. Radiat Prot Dosim 113:396–402CrossRef Edwards AA, Lindholm C, Darroudi F et al (2005) Review of translocations detected by FISH for retrospective biological dosimetry applications. Radiat Prot Dosim 113:396–402CrossRef
14.
go back to reference Lobrich M, Rief N, Kuhne M et al (2005) In vivo formation and repair of DNA double-strand breaks after computed tomography examinations. Proc Natl Acad Sci U S A 102:8984–8989CrossRefPubMed Lobrich M, Rief N, Kuhne M et al (2005) In vivo formation and repair of DNA double-strand breaks after computed tomography examinations. Proc Natl Acad Sci U S A 102:8984–8989CrossRefPubMed
15.
go back to reference Rothkamm K, Balroop S, Shekhdar J, Fernie P, Goh V (2007) Leukocyte DNA damage after multi-detector row CT: a quantitative biomarker of low-level radiation exposure. Radiology 242:244–251CrossRefPubMed Rothkamm K, Balroop S, Shekhdar J, Fernie P, Goh V (2007) Leukocyte DNA damage after multi-detector row CT: a quantitative biomarker of low-level radiation exposure. Radiology 242:244–251CrossRefPubMed
16.
go back to reference Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268CrossRefPubMed Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268CrossRefPubMed
17.
go back to reference Rogakou EP, Pilch DR, Orr AH, Ivanova VS, Bonner WM (1998) DNA double-stranded breaks induce histone H2AX phosphorylation on serine 139. J Biol Chem 273:5858–5868CrossRefPubMed Rogakou EP, Pilch DR, Orr AH, Ivanova VS, Bonner WM (1998) DNA double-stranded breaks induce histone H2AX phosphorylation on serine 139. J Biol Chem 273:5858–5868CrossRefPubMed
18.
go back to reference Rothkamm K, Lobrich M (2003) Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses. Proc Natl Acad Sci U S A 100:5057–5062CrossRefPubMed Rothkamm K, Lobrich M (2003) Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses. Proc Natl Acad Sci U S A 100:5057–5062CrossRefPubMed
19.
go back to reference Haberle L, Pfahlberg A, Gefeller O (2009) Assessment of multiple ordinal endpoints. Biom J 51:217–226CrossRefPubMed Haberle L, Pfahlberg A, Gefeller O (2009) Assessment of multiple ordinal endpoints. Biom J 51:217–226CrossRefPubMed
21.
go back to reference Kuefner MA, Grudzenski S, Schwab SA et al (2009) DNA double-strand breaks and their repair in blood lymphocytes of patients undergoing angiographic procedures. Invest Radiol 44:440–446CrossRefPubMed Kuefner MA, Grudzenski S, Schwab SA et al (2009) DNA double-strand breaks and their repair in blood lymphocytes of patients undergoing angiographic procedures. Invest Radiol 44:440–446CrossRefPubMed
22.
go back to reference Gutstein A, Dey D, Cheng V et al (2008) Algorithm for radiation dose reduction with helical dual source coronary computed tomography angiography in clinical practice. J Cardiovasc Comput Tomogr 2:311–322CrossRefPubMed Gutstein A, Dey D, Cheng V et al (2008) Algorithm for radiation dose reduction with helical dual source coronary computed tomography angiography in clinical practice. J Cardiovasc Comput Tomogr 2:311–322CrossRefPubMed
23.
go back to reference Hermann F, Martinoff S, Meyer T et al (2008) Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery. Invest Radiol 43:253–260CrossRefPubMed Hermann F, Martinoff S, Meyer T et al (2008) Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery. Invest Radiol 43:253–260CrossRefPubMed
24.
go back to reference McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243:775–784CrossRefPubMed McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243:775–784CrossRefPubMed
25.
go back to reference Weustink AC, Mollet NR, Neefjes LA et al (2009) Preserved diagnostic performance of dual-source CT coronary angiography with reduced radiation exposure and cancer risk. Radiology 252:53–60CrossRefPubMed Weustink AC, Mollet NR, Neefjes LA et al (2009) Preserved diagnostic performance of dual-source CT coronary angiography with reduced radiation exposure and cancer risk. Radiology 252:53–60CrossRefPubMed
26.
go back to reference Grudzenski S, Kuefner MA, Heckmann MB, Uder M, Lobrich M (2009) Contrast medium-enhanced radiation damage caused by CT examinations. Radiology 253:706–714CrossRefPubMed Grudzenski S, Kuefner MA, Heckmann MB, Uder M, Lobrich M (2009) Contrast medium-enhanced radiation damage caused by CT examinations. Radiology 253:706–714CrossRefPubMed
27.
go back to reference Norman A, Cochran ST, Sayre JW (2001) Meta-analysis of increases in micronuclei in peripheral blood lymbphocytes after angiography or excretory urography. Radiat Res 155:740–743CrossRefPubMed Norman A, Cochran ST, Sayre JW (2001) Meta-analysis of increases in micronuclei in peripheral blood lymbphocytes after angiography or excretory urography. Radiat Res 155:740–743CrossRefPubMed
28.
go back to reference Rube CE, Grudzenski S, Kuhne M et al (2008) DNA double-strand break repair of blood lymphocytes and normal tissues analysed in a preclinical mouse model: implications for radiosensitivity testing. Clin Cancer Res 14:6546–6555CrossRefPubMed Rube CE, Grudzenski S, Kuhne M et al (2008) DNA double-strand break repair of blood lymphocytes and normal tissues analysed in a preclinical mouse model: implications for radiosensitivity testing. Clin Cancer Res 14:6546–6555CrossRefPubMed
Metadata
Title
Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography
Authors
M. A. Kuefner
S. Grudzenski
J. Hamann
S. Achenbach
Michael Lell
K. Anders
S. A. Schwab
L. Häberle
M. Löbrich
M. Uder
Publication date
01-12-2010
Publisher
Springer-Verlag
Published in
European Radiology / Issue 12/2010
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1873-9

Other articles of this Issue 12/2010

European Radiology 12/2010 Go to the issue