Skip to main content
Top
Published in: European Radiology 12/2009

01-12-2009 | Experimental

Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits

Authors: Long-Jiang Zhang, Xue Chai, Sheng-Yong Wu, Yan-E Zhao, Xiao-Bo Hu, Yu-Xiao Hu, Yang-Bo Xue, Gui-Fen Yang, Hong Zhu, Guang-Ming Lu

Published in: European Radiology | Issue 12/2009

Login to get access

Abstract

The purpose of the study was to compare the ability of dual energy CT (DECT) and perfusion scintigraphy (PS) to detect pulmonary embolism (PE) in a rabbit model. Gelfoam (n = 20) or saline (n = 4) was injected into the femoral vein of rabbits. After 2 h, DECT pulmonary angiography (CTPA) was used to create blood flow imaging (BFI) and fusion images. The rabbits then underwent PS. Pathological determination of locations and numbers of lung lobes with PE was recorded. The sensitivity and specificity for BFI, CTPA, fused images and PS were calculated using the pathological results as reference standards. Compared with pathological evaluation, CTPA correctly identified PE in 40 lobes and absence of emboli in 80 lobes, corresponding to a sensitivity and specificity of 100%. BFI and fused images correctly identified PE in 40 lobes and the absence of emboli in 78 lobes, corresponding to a sensitivity and specificity of 100% and 98%, respectively. PS correctly detected 27 lobes with PE and 65 lobes without PE, corresponding to a sensitivity and specificity of 68% and 81%, respectively. BFI, CTPA and fused images derived from a single contrast-enhanced DECT provide a higher diagnostic accuracy of detecting PE than PS in a rabbit model.
Literature
1.
go back to reference Zhang LJ, Wang YZ, Huang W, Chen P, Zhou CS, Lu GM (2008) In vivo visualization of sinuatrial nodal artery using dual-source CT. Circ J 72:1615–1620CrossRefPubMed Zhang LJ, Wang YZ, Huang W, Chen P, Zhou CS, Lu GM (2008) In vivo visualization of sinuatrial nodal artery using dual-source CT. Circ J 72:1615–1620CrossRefPubMed
2.
go back to reference Lu GM, Zhang LJ, Guo H, Huang W, Merges RD (2008) Comparison of myocardial bridging by dual-source CT with conventional coronary angiography. Circ J 72:1079–1085CrossRefPubMed Lu GM, Zhang LJ, Guo H, Huang W, Merges RD (2008) Comparison of myocardial bridging by dual-source CT with conventional coronary angiography. Circ J 72:1079–1085CrossRefPubMed
3.
go back to reference Brodoefel H, Burgstahler C, Tsiflikas I et al (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247:346–355CrossRefPubMed Brodoefel H, Burgstahler C, Tsiflikas I et al (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247:346–355CrossRefPubMed
4.
go back to reference Takahashi N, Hartman RP, Vrtiska TJ et al (2008) Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. Am J Roentgenol 190:1169–1173CrossRef Takahashi N, Hartman RP, Vrtiska TJ et al (2008) Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. Am J Roentgenol 190:1169–1173CrossRef
5.
go back to reference Grosjean R, Sauer B, Guerra RM et al (2008) Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion. AJR Am J Roentgenol 190:720–728CrossRefPubMed Grosjean R, Sauer B, Guerra RM et al (2008) Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion. AJR Am J Roentgenol 190:720–728CrossRefPubMed
6.
go back to reference Boll DT, Merkle EM, Paulson EK, Fleiter TR (2008) Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom. Radiology 247:687–695CrossRefPubMed Boll DT, Merkle EM, Paulson EK, Fleiter TR (2008) Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom. Radiology 247:687–695CrossRefPubMed
7.
go back to reference Sun C, Miao F, Wang XM et al (2008) An initial qualitative study of dual-energy CT in the knee ligaments. Surg Radiol Anat 30:443–447CrossRefPubMed Sun C, Miao F, Wang XM et al (2008) An initial qualitative study of dual-energy CT in the knee ligaments. Surg Radiol Anat 30:443–447CrossRefPubMed
8.
go back to reference Stolzmann P, Frauenfelder T, Pfammatter T et al (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691CrossRefPubMed Stolzmann P, Frauenfelder T, Pfammatter T et al (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691CrossRefPubMed
9.
go back to reference Chandarana H, Godoy M, Vlahos I et al (2008) Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations. Radiology 249:692–700CrossRefPubMed Chandarana H, Godoy M, Vlahos I et al (2008) Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations. Radiology 249:692–700CrossRefPubMed
10.
go back to reference Ruzsics B, Lee H, Zwerner PL, Gebregziabher M, Costello P, Schoepf UJ (2008) Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia—initial experience. Eur Radiol 18:2414–2424CrossRefPubMed Ruzsics B, Lee H, Zwerner PL, Gebregziabher M, Costello P, Schoepf UJ (2008) Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia—initial experience. Eur Radiol 18:2414–2424CrossRefPubMed
11.
go back to reference Chae EJ, Seo JB, Goo HW et al (2008) Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. Radiology 248:615–624CrossRefPubMed Chae EJ, Seo JB, Goo HW et al (2008) Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. Radiology 248:615–624CrossRefPubMed
12.
go back to reference Chae EJ, Song JW, Seo JB, Krauss B, Jang YM, Song KS (2008) Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience. Radiology 249:671–681CrossRefPubMed Chae EJ, Song JW, Seo JB, Krauss B, Jang YM, Song KS (2008) Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience. Radiology 249:671–681CrossRefPubMed
13.
go back to reference Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517CrossRefPubMed Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517CrossRefPubMed
14.
go back to reference Fink C, Johnson TR, Michaely HJ et al (2008) Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results. Rofo 180:879–883PubMed Fink C, Johnson TR, Michaely HJ et al (2008) Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results. Rofo 180:879–883PubMed
15.
go back to reference Thieme SF, Becker CR, Hacker M, Nikolaou K, Reiser MF, Johnson TR (2008) Dual energy CT for the assessment of lung perfusion—correlation to scintigraphy. Eur J Radiol 68:369–374CrossRefPubMed Thieme SF, Becker CR, Hacker M, Nikolaou K, Reiser MF, Johnson TR (2008) Dual energy CT for the assessment of lung perfusion—correlation to scintigraphy. Eur J Radiol 68:369–374CrossRefPubMed
16.
go back to reference Pontana F, Faivre JB, Remy-Jardin M et al (2008) Lung perfusion with dual-energy multidetector-row CT (MDCT) feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol 15:1494–1504CrossRefPubMed Pontana F, Faivre JB, Remy-Jardin M et al (2008) Lung perfusion with dual-energy multidetector-row CT (MDCT) feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol 15:1494–1504CrossRefPubMed
17.
go back to reference Hoey ET, Gopalan D, Ganesh V et al (2009) Dual-energy CT pulmonary angiography: a novel technique for assessing acute and chronic pulmonary thromboembolism. Clin Radiol 64:414–419CrossRefPubMed Hoey ET, Gopalan D, Ganesh V et al (2009) Dual-energy CT pulmonary angiography: a novel technique for assessing acute and chronic pulmonary thromboembolism. Clin Radiol 64:414–419CrossRefPubMed
18.
go back to reference Goldin JG, Yoon HC, Greaser LE 3rd, Nishimura EK (1998) Detection of pulmonary emboli at the segmental and subsegmental level with electron-beam CT: validation in a porcine model. Acad Radiol 5:503–508CrossRefPubMed Goldin JG, Yoon HC, Greaser LE 3rd, Nishimura EK (1998) Detection of pulmonary emboli at the segmental and subsegmental level with electron-beam CT: validation in a porcine model. Acad Radiol 5:503–508CrossRefPubMed
19.
go back to reference Hurst DR, Kazerooni EA, Stafford-Johnson D et al (1999) Diagnosis of pulmonary embolism: comparison of CT angiography and MR angiography in canines. J Vasc Interv Radiol 10:309–318CrossRefPubMed Hurst DR, Kazerooni EA, Stafford-Johnson D et al (1999) Diagnosis of pulmonary embolism: comparison of CT angiography and MR angiography in canines. J Vasc Interv Radiol 10:309–318CrossRefPubMed
20.
go back to reference Stein PD, Gottschalk A (2000) Review of criteria appropriate for a very low probability of pulmonary embolism on ventilation-perfusion lung scans: a position paper. Radiographics 20:99–105PubMed Stein PD, Gottschalk A (2000) Review of criteria appropriate for a very low probability of pulmonary embolism on ventilation-perfusion lung scans: a position paper. Radiographics 20:99–105PubMed
22.
go back to reference The PIOPED Investigators (1990) Value of the ventilation/perfusion scan in acute pulmonary embolism: results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 263:2753–2759CrossRef The PIOPED Investigators (1990) Value of the ventilation/perfusion scan in acute pulmonary embolism: results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 263:2753–2759CrossRef
23.
go back to reference Anderson DR, Kahn SR, Rodger MA et al (2007) Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism: a randomized controlled trial. JAMA 298:2743–2753CrossRefPubMed Anderson DR, Kahn SR, Rodger MA et al (2007) Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism: a randomized controlled trial. JAMA 298:2743–2753CrossRefPubMed
24.
go back to reference Sostman HD, Miniati M, Gottschalk A, Matta F, Stein PD, Pistolesi M (2008) Sensitivity and specificity of perfusion scintigraphy combined with chest radiography for acute pulmonary embolism in PIOPED II. J Nucl Med 49:1741–1748CrossRefPubMed Sostman HD, Miniati M, Gottschalk A, Matta F, Stein PD, Pistolesi M (2008) Sensitivity and specificity of perfusion scintigraphy combined with chest radiography for acute pulmonary embolism in PIOPED II. J Nucl Med 49:1741–1748CrossRefPubMed
25.
go back to reference Sostman HD, Stein PD, Gottschalk A, Matta F, Hull R, Goodman L (2008) Acute pulmonary embolism: sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study. Radiology 246:941–946CrossRefPubMed Sostman HD, Stein PD, Gottschalk A, Matta F, Hull R, Goodman L (2008) Acute pulmonary embolism: sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study. Radiology 246:941–946CrossRefPubMed
26.
go back to reference Remy-Jardin M, Pistolesi M, Goodman LR et al (2007) Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 245:315–329CrossRefPubMed Remy-Jardin M, Pistolesi M, Goodman LR et al (2007) Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 245:315–329CrossRefPubMed
27.
go back to reference Ritchie G, McGurk S, McCreath C, Graham C, Murchison JT (2007) Prospective evaluation of unsuspected pulmonary embolism on contrast enhanced multidetector CT (MDCT) scanning. Thorax. 62:536–540CrossRefPubMed Ritchie G, McGurk S, McCreath C, Graham C, Murchison JT (2007) Prospective evaluation of unsuspected pulmonary embolism on contrast enhanced multidetector CT (MDCT) scanning. Thorax. 62:536–540CrossRefPubMed
28.
go back to reference Wildberger JE, Schoepf UJ, Mahnken AH et al (2005) Approaches to CT perfusion imaging in pulmonary embolism. Semin Roentgenol 40:64–73CrossRefPubMed Wildberger JE, Schoepf UJ, Mahnken AH et al (2005) Approaches to CT perfusion imaging in pulmonary embolism. Semin Roentgenol 40:64–73CrossRefPubMed
29.
go back to reference Zhang LJ, Zhao YE, Wu SY et al (2009) Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits. Radiology 252:61–70CrossRefPubMed Zhang LJ, Zhao YE, Wu SY et al (2009) Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits. Radiology 252:61–70CrossRefPubMed
Metadata
Title
Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits
Authors
Long-Jiang Zhang
Xue Chai
Sheng-Yong Wu
Yan-E Zhao
Xiao-Bo Hu
Yu-Xiao Hu
Yang-Bo Xue
Gui-Fen Yang
Hong Zhu
Guang-Ming Lu
Publication date
01-12-2009
Publisher
Springer-Verlag
Published in
European Radiology / Issue 12/2009
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1518-z

Other articles of this Issue 12/2009

European Radiology 12/2009 Go to the issue