Skip to main content
Top
Published in: European Radiology 9/2006

01-09-2006 | Gastrointestinal

Imaging of small intestinal Crohn’s disease: comparison between MR enteroclysis and conventional enteroclysis

Authors: Nicholas C. Gourtsoyiannis, John Grammatikakis, George Papamastorakis, John Koutroumbakis, Panos Prassopoulos, Maria Rousomoustakaki, Nickolas Papanikolaou

Published in: European Radiology | Issue 9/2006

Login to get access

Abstract

The purpose of this study was to compare MR enteroclysis (MRE) with conventional enteroclysis (CE) in patients with small intestinal Crohn’s disease. Fifty-two consecutive patients with known or suspected Crohn’s disease underwent MR and conventional enteroclysis, which was considered the gold standard. Eleven imaging features, classified in three groups, mucosal, transmural and extraintestinal, were subjectively evaluated by two experienced radiologists. MRE and CE were in full agreement in revealing, localizing and estimating the length of all involved segments of the small bowel. The sensitivity of MRE for the detection of superficial ulcers, fold distortion and fold thickening was 40, 30 and 62.5%, respectively. The sensitivity of MRE for the detection of deep ulcers, cobble-stoning pattern, stenosis and prestenostic dilatation was 89.5, 92.3, 100 and 100%, respectively. Additional findings demonstrated on MRE images included fibrofatty proliferation in 15 cases and mesenteric lymphadenopathy in 19 cases. MRE strongly correlates with CE in the detection of individual lesions expressing small intestinal Crohn’s disease. It provides additional information from the mesenteries; however, its capability to detect subtle lesions is still inferior to conventional enteroclysis.
Literature
1.
go back to reference Nolan DJ, Gourtsoyiannis NC (1980) Crohn’s disease of the small intestine: a review of the radiological appearances in 100 consecutive patients examined by a barium infusion technique. Clin Radiol 31(5):597–603PubMedCrossRef Nolan DJ, Gourtsoyiannis NC (1980) Crohn’s disease of the small intestine: a review of the radiological appearances in 100 consecutive patients examined by a barium infusion technique. Clin Radiol 31(5):597–603PubMedCrossRef
2.
go back to reference Ruiz-Cruces R, Ruiz F, Perez-Martinez M, Lopez J, Tort Ausina I, de los Rios AD (2000) Patient dose from barium procedures. Br J Radiol 73(871):752–761PubMed Ruiz-Cruces R, Ruiz F, Perez-Martinez M, Lopez J, Tort Ausina I, de los Rios AD (2000) Patient dose from barium procedures. Br J Radiol 73(871):752–761PubMed
3.
go back to reference Umschaden HW, Szolar D, Gasser J, Umschaden M, Haselbach H (2000) Small-bowel disease: comparison of MR enteroclysis images with conventional enteroclysis and surgical findings. Radiology 215:717–725PubMed Umschaden HW, Szolar D, Gasser J, Umschaden M, Haselbach H (2000) Small-bowel disease: comparison of MR enteroclysis images with conventional enteroclysis and surgical findings. Radiology 215:717–725PubMed
4.
go back to reference Gourtsoyiannis N, Papanikolaou N, Grammatikakis J, Maris T, Prassopoulos P (2000) Magnetic resonance imaging of the small bowel using a True-FISP sequence after enteroclysis with water solution. Invest Radiol 35(12):707–711PubMedCrossRef Gourtsoyiannis N, Papanikolaou N, Grammatikakis J, Maris T, Prassopoulos P (2000) Magnetic resonance imaging of the small bowel using a True-FISP sequence after enteroclysis with water solution. Invest Radiol 35(12):707–711PubMedCrossRef
5.
go back to reference Gourtsoyiannis NC, Papanikolaou N, Grammatikakis J, Maris T, Prassopoulos P (2001) MR enteroclysis protocol optimization: comparison between 3d FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences. Eur Radiol 11(6):908–913PubMedCrossRef Gourtsoyiannis NC, Papanikolaou N, Grammatikakis J, Maris T, Prassopoulos P (2001) MR enteroclysis protocol optimization: comparison between 3d FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences. Eur Radiol 11(6):908–913PubMedCrossRef
6.
go back to reference Prassopoulos P, Papanikolaou N, Grammatikakis J, Rousomoustakaki M, Maris T, Gourtsoyiannis N (2001) MR enteroclysis imaging of crohn disease. Radiographics 21:161–172 Prassopoulos P, Papanikolaou N, Grammatikakis J, Rousomoustakaki M, Maris T, Gourtsoyiannis N (2001) MR enteroclysis imaging of crohn disease. Radiographics 21:161–172
7.
go back to reference Rofsky NM, Lee VS, Laub G, Pollack MA, Krinsky GA, Thomasson D, Ambrosino MM, Weinreb JC (1999) Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 212(3):876–884PubMed Rofsky NM, Lee VS, Laub G, Pollack MA, Krinsky GA, Thomasson D, Ambrosino MM, Weinreb JC (1999) Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 212(3):876–884PubMed
8.
go back to reference Narin B, Ajaj W, Gohde S et al (2004) Combined small and large bowel MR imaging in patients with Crohn’s disease: a feasibility study. Eur Radiol 14:1535–1542PubMedCrossRef Narin B, Ajaj W, Gohde S et al (2004) Combined small and large bowel MR imaging in patients with Crohn’s disease: a feasibility study. Eur Radiol 14:1535–1542PubMedCrossRef
9.
go back to reference Lauenstein TC, Schneemann H, Vogt FM, Herborn CU, Ruhm SG, Debatin JF (2003) Optimization of oral contrast agents for MR imaging of the small bowel. Radiology 228:279–283PubMedCrossRef Lauenstein TC, Schneemann H, Vogt FM, Herborn CU, Ruhm SG, Debatin JF (2003) Optimization of oral contrast agents for MR imaging of the small bowel. Radiology 228:279–283PubMedCrossRef
10.
go back to reference Gourtsoyiannis N, Papanikolaou N, Rieber A, et al (2002) Evaluation of the small intestine by MR imaging. In: Gourtsoyiannis N (ed) Radiological imaging of the small intestine. Springer, Berlin Heidelberg New York, pp 157–170 Gourtsoyiannis N, Papanikolaou N, Rieber A, et al (2002) Evaluation of the small intestine by MR imaging. In: Gourtsoyiannis N (ed) Radiological imaging of the small intestine. Springer, Berlin Heidelberg New York, pp 157–170
11.
go back to reference Schunk K, Kern A, Oberholzer K, Kalden P, Mayer I, Orth T, Wanitschke R (2000) Hydro-MRI in Crohn’s disease. Appraisal of disease activity. Invest Radiol 35:431–437PubMedCrossRef Schunk K, Kern A, Oberholzer K, Kalden P, Mayer I, Orth T, Wanitschke R (2000) Hydro-MRI in Crohn’s disease. Appraisal of disease activity. Invest Radiol 35:431–437PubMedCrossRef
12.
go back to reference Maccioni F, Viscido A, Broglia L, Marrollo M, Masciangelo R, Caprilli R, Rossi P (2000) Evaluation of Crohn’s disease activity with magnetic resonance imaging. Abdom Imaging 25:219–228PubMedCrossRef Maccioni F, Viscido A, Broglia L, Marrollo M, Masciangelo R, Caprilli R, Rossi P (2000) Evaluation of Crohn’s disease activity with magnetic resonance imaging. Abdom Imaging 25:219–228PubMedCrossRef
13.
go back to reference Gourtsoyiannis N, Papanikolaou N, Grammatikakis J, Papamastorakis G, Prassopoulos P, Roussomoustakaki M (2004) Assessment of Crohn’s disease activity in the small bowel with MR and conventional enteroclysis: preliminary results. Eur Radiol 14(6):1017–1024PubMedCrossRef Gourtsoyiannis N, Papanikolaou N, Grammatikakis J, Papamastorakis G, Prassopoulos P, Roussomoustakaki M (2004) Assessment of Crohn’s disease activity in the small bowel with MR and conventional enteroclysis: preliminary results. Eur Radiol 14(6):1017–1024PubMedCrossRef
14.
go back to reference Low RN, Sebrechts CP, Politoske DA, Bennett MT, Flores S, Snyder RJ, Pressman JH (2002) Crohn disease with endoscopic correlation: single-shot fast spin echo and gadolinium-enhanced fat-supressed spoiled gradient echo MR imaging. Radiology 222:652–660PubMedCrossRef Low RN, Sebrechts CP, Politoske DA, Bennett MT, Flores S, Snyder RJ, Pressman JH (2002) Crohn disease with endoscopic correlation: single-shot fast spin echo and gadolinium-enhanced fat-supressed spoiled gradient echo MR imaging. Radiology 222:652–660PubMedCrossRef
15.
go back to reference Koh DM, Miao Y, Chinn RJ et al (2001) MR Imaging evaluation of the activity in Crohn’s disease. AJR 177:1325–1332PubMed Koh DM, Miao Y, Chinn RJ et al (2001) MR Imaging evaluation of the activity in Crohn’s disease. AJR 177:1325–1332PubMed
16.
go back to reference Semelka RC, Chung JJ, Hussain SM, Marcos HB, Woosley JT (2001) Chronic hepatitis: correlation of early patchy and late linear enhancement patterns on gadolinium-enhanced MR images with histopathology initial experience. J Magn Reson Imaging 13(3):385–391PubMedCrossRef Semelka RC, Chung JJ, Hussain SM, Marcos HB, Woosley JT (2001) Chronic hepatitis: correlation of early patchy and late linear enhancement patterns on gadolinium-enhanced MR images with histopathology initial experience. J Magn Reson Imaging 13(3):385–391PubMedCrossRef
Metadata
Title
Imaging of small intestinal Crohn’s disease: comparison between MR enteroclysis and conventional enteroclysis
Authors
Nicholas C. Gourtsoyiannis
John Grammatikakis
George Papamastorakis
John Koutroumbakis
Panos Prassopoulos
Maria Rousomoustakaki
Nickolas Papanikolaou
Publication date
01-09-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 9/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0248-8

Other articles of this Issue 9/2006

European Radiology 9/2006 Go to the issue