Skip to main content
Top
Published in: European Radiology 2/2004

01-02-2004 | Cardiac

Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser

Authors: Filippo Cademartiri, Nico Mollet, Aad van der Lugt, Koen Nieman, Peter M. T. Pattynama, Pim J. de Feyter, Gabriel P. Krestin

Published in: European Radiology | Issue 2/2004

Login to get access

Abstract

The aim of this study was to investigate the usefulness of saline chaser in 16-row multislice CT (16-MSCT) coronary angiography. Forty-two patients were divided into two groups for contrast material (CM) administration: group 1 (140 ml at 4 ml/s) and group 2 (100 ml at 4 ml/s followed by 40 ml of saline chaser at 4 ml/s). All patients underwent retrospectively ECG-gated 16-MSCT coronary angiography. The attenuation at the origin coronary vessels was assessed. Three regions of interest (ROIs) were drawn throughout the data set: (a) ascending aorta (ROI 1); (b) descending aorta (ROI 2); and (c) pulmonary artery (ROI 3). The attenuation in the superior vena cava was recorded (ROI 4). The average attenuation and the slope were calculated in each ROI and differences were assessed with a Student’s t test. The average attenuation in the coronary vessels was not significantly different in the two groups. The average attenuations in ROI 1 were 325 and 327 HU, in ROI 2 were 328 and 329 HU and in ROI 3 were 357 and 320 HU, for groups 1 and 2, respectively (p>0.05). The slopes in ROI 1 were −0.2 and 1.1, in ROI 2 were 2.8 and 2.1 (p>0.05) and in ROI3 were 3.9 and −9.0 (p<0.05), for groups 1 and 2, respectively. The average attenuations in ROI 4 were 927 and 643 HU (p<0.05), for groups 1 and 2, respectively. One hundred milliliters of CM with 40 ml of saline chaser provides the same attenuation as 140 ml of CM (35% less) with decreased hyper-attenuation in the superior vena cava.
Literature
1.
go back to reference Flohr T, Stierstorfer K, Bruder H, Simon J, Schaller S (2002) New technical developments in multislice CT. Part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:839–845CrossRefPubMed Flohr T, Stierstorfer K, Bruder H, Simon J, Schaller S (2002) New technical developments in multislice CT. Part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:839–845CrossRefPubMed
2.
go back to reference Flohr T, Bruder H, Stierstorfer K, Simon J, Schaller S, Ohnesorge B (2002) New technical developments in multislice CT. Part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:1022–1027CrossRefPubMed Flohr T, Bruder H, Stierstorfer K, Simon J, Schaller S, Ohnesorge B (2002) New technical developments in multislice CT. Part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:1022–1027CrossRefPubMed
3.
go back to reference Heuschmid M, Kuttner A, Flohr T, Wildberger JE, Lell M, Kopp AF, Schroder S, Baum U, Schaller S, Hartung A, Ohnesorge B, Claussen CD (2002) Visualization of coronary arteries in CT as assessed by a new 16-slice technology and reduced gantry rotation time: first experiences. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:721–724 [in German]CrossRefPubMed Heuschmid M, Kuttner A, Flohr T, Wildberger JE, Lell M, Kopp AF, Schroder S, Baum U, Schaller S, Hartung A, Ohnesorge B, Claussen CD (2002) Visualization of coronary arteries in CT as assessed by a new 16-slice technology and reduced gantry rotation time: first experiences. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:721–724 [in German]CrossRefPubMed
4.
go back to reference Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed
5.
go back to reference Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed
6.
go back to reference Cademartiri F, Nieman K, Raaymakers RH, de Feyter PJ, Flohr T, Alfieri O, Krestin GP (2003) Non-invasive demonstration of coronary artery anomaly performed using 16-slice multidetector spiral computed tomography. Ital Heart J 4:56–59PubMed Cademartiri F, Nieman K, Raaymakers RH, de Feyter PJ, Flohr T, Alfieri O, Krestin GP (2003) Non-invasive demonstration of coronary artery anomaly performed using 16-slice multidetector spiral computed tomography. Ital Heart J 4:56–59PubMed
7.
go back to reference Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin GP (2002) Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr 26:598–607CrossRefPubMed Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin GP (2002) Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr 26:598–607CrossRefPubMed
8.
go back to reference Kopka L, Rodenwaldt J, Fischer U, Mueller DW, Oestmann JW, Grabbe E (1996) Dual-phase helical CT of the liver: effects of bolus tracking and different volumes of contrast material. Radiology 201:321–326PubMed Kopka L, Rodenwaldt J, Fischer U, Mueller DW, Oestmann JW, Grabbe E (1996) Dual-phase helical CT of the liver: effects of bolus tracking and different volumes of contrast material. Radiology 201:321–326PubMed
9.
go back to reference Kirchner J, Kickuth R, Laufer U, Noack M, Liermann D (2000) Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients. Clin Radiol 55:368–373PubMed Kirchner J, Kickuth R, Laufer U, Noack M, Liermann D (2000) Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients. Clin Radiol 55:368–373PubMed
10.
go back to reference Mehnert F, Pereira PL, Trubenbach J, Kopp AF, Claussen CD (2001) Automatic bolus tracking in monophasic spiral CT of the liver: liver-to-lesion conspicuity. Eur Radiol 11:580–584CrossRefPubMed Mehnert F, Pereira PL, Trubenbach J, Kopp AF, Claussen CD (2001) Automatic bolus tracking in monophasic spiral CT of the liver: liver-to-lesion conspicuity. Eur Radiol 11:580–584CrossRefPubMed
11.
go back to reference Mehnert F, Pereira PL, Trubenbach J, Kopp AF, Claussen CD (2001) Biphasic spiral CT of the liver: Automatic bolus tracking or time delay? Eur Radiol 11:427–431PubMed Mehnert F, Pereira PL, Trubenbach J, Kopp AF, Claussen CD (2001) Biphasic spiral CT of the liver: Automatic bolus tracking or time delay? Eur Radiol 11:427–431PubMed
12.
go back to reference Sandstede JJ, Tschammler A, Beer M, Vogelsang C, Wittenberg G, Hahn D (2001) Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol 11:1396–1400PubMed Sandstede JJ, Tschammler A, Beer M, Vogelsang C, Wittenberg G, Hahn D (2001) Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol 11:1396–1400PubMed
13.
go back to reference Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double-power injector in helical CT of the thorax. Am J Roentgenol 174:1049–1053 Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double-power injector in helical CT of the thorax. Am J Roentgenol 174:1049–1053
14.
go back to reference Hopper KD, Mosher TJ, Kasales CJ, TenHave TR, Tully DA, Weaver JS (1997) Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 205:269–271PubMed Hopper KD, Mosher TJ, Kasales CJ, TenHave TR, Tully DA, Weaver JS (1997) Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 205:269–271PubMed
15.
go back to reference Bader TR, Prokesch RW, Grabenwoger F (2000) Timing of the hepatic arterial phase during contrast-enhanced computed tomography of the liver: assessment of normal values in 25 volunteers. Invest Radiol 35:486–492CrossRefPubMed Bader TR, Prokesch RW, Grabenwoger F (2000) Timing of the hepatic arterial phase during contrast-enhanced computed tomography of the liver: assessment of normal values in 25 volunteers. Invest Radiol 35:486–492CrossRefPubMed
16.
go back to reference Garcia P, Genin G, Bret PM, Bonaldi VM, Reinhold C, Atri M (1999) Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model. Abdom Imaging 24:597–603CrossRefPubMed Garcia P, Genin G, Bret PM, Bonaldi VM, Reinhold C, Atri M (1999) Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model. Abdom Imaging 24:597–603CrossRefPubMed
17.
go back to reference Han JK, Kim AY, Lee KY, Seo JB, Kim TK, Choi BI, Lhee CS, Han MC (2000) Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 24:400–406CrossRefPubMed Han JK, Kim AY, Lee KY, Seo JB, Kim TK, Choi BI, Lhee CS, Han MC (2000) Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 24:400–406CrossRefPubMed
18.
go back to reference Yamashita Y, Komohara Y, Takahashi M, Uchida M, Hayabuchi N, Shimizu T, Narabayashi I (2000) Abdominal helical CT: evaluation of optimal doses of intravenous contrast material—a prospective randomized study. Radiology 216:718–723 Yamashita Y, Komohara Y, Takahashi M, Uchida M, Hayabuchi N, Shimizu T, Narabayashi I (2000) Abdominal helical CT: evaluation of optimal doses of intravenous contrast material—a prospective randomized study. Radiology 216:718–723
19.
go back to reference Dorio PJ, Lee FT Jr, Henseler KP, Pilot M, Pozniak MA, Winter TC III, Shock SA (2003) Using a saline chaser to decrease contrast media in abdominal CT. Am J Roentgenol 180:929–934 Dorio PJ, Lee FT Jr, Henseler KP, Pilot M, Pozniak MA, Winter TC III, Shock SA (2003) Using a saline chaser to decrease contrast media in abdominal CT. Am J Roentgenol 180:929–934
Metadata
Title
Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser
Authors
Filippo Cademartiri
Nico Mollet
Aad van der Lugt
Koen Nieman
Peter M. T. Pattynama
Pim J. de Feyter
Gabriel P. Krestin
Publication date
01-02-2004
Publisher
Springer-Verlag
Published in
European Radiology / Issue 2/2004
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2188-x

Other articles of this Issue 2/2004

European Radiology 2/2004 Go to the issue

Interpretation corner

A frontal mass (2004:2a)