Abstract

To compare the sensitivity of different electrodiagnostic tests on the same hand affected by mild carpal tunnel syndrome (CTS), 189 hands with the clinical diagnosis of CTS and 61 hands of healthy persons were evaluated prospectively. On all hands, median sensory studies from digits 1, 2, 3, 4, and the palm-to-wrist segment from digit 3 and medial motor latency were recorded. Sixty-two hands with delayed motor latency (>4.2 ms) were excluded to ensure that only mild cases were enrolled. Sensory median-radial latency differences from the thumb, median-ulnar latency difference between second and fifth digits, and median-ulnar latency difference from the fourth digit were calculated in each limb. Sensory studies of only one median innervated digit failed to diagnose 15–20% of hands. Conduction velocity at the palm-to-wrist segment was the most sensitive, diagnosing 99% of cases. In comparative tests, median radial sensory latency difference from the first digit was the most sensitive (94%), and median ulnar latency difference from the fourth digit was the least (85%) sensitive. Segmental measurement has the highest diagnostic yield and may be used first in the evaluation of CTS.
Literature
1.
go back to reference Braun RM, Jackson WJ (1994) Electrical studies as a prognostic factor in the surgical treatment of carpal tunnel syndrome. J Hand Surg [Am] 19:893–900 Braun RM, Jackson WJ (1994) Electrical studies as a prognostic factor in the surgical treatment of carpal tunnel syndrome. J Hand Surg [Am] 19:893–900
2.
go back to reference Corwin HM, Kasdan ML (1998) Electrodiagnostic reports of median neuropathy at the wrist. J Hand Surg [Am] 23:55–57 Corwin HM, Kasdan ML (1998) Electrodiagnostic reports of median neuropathy at the wrist. J Hand Surg [Am] 23:55–57
3.
go back to reference Finsen V, Russwurm H (2001) Neurophysiology not required before surgery for typical carpal tunnel syndrome. J Hand Surg [Br] 26:1:61–64 Finsen V, Russwurm H (2001) Neurophysiology not required before surgery for typical carpal tunnel syndrome. J Hand Surg [Br] 26:1:61–64
4.
go back to reference Glowacki KA, Breen CJ, Sachar K, Weiss A-PC (1996) Electrodiagnostic testing and carpal tunnel release outcome. J Hand Surg [Am] 21:117–122 Glowacki KA, Breen CJ, Sachar K, Weiss A-PC (1996) Electrodiagnostic testing and carpal tunnel release outcome. J Hand Surg [Am] 21:117–122
5.
go back to reference Gunnarson LG, Amilon A, Hellstrand P, Leissner P, Philipson L (1997) The diagnosis of carpal tunnel syndrome. J Hand Surg [Br] 22:34–37 Gunnarson LG, Amilon A, Hellstrand P, Leissner P, Philipson L (1997) The diagnosis of carpal tunnel syndrome. J Hand Surg [Br] 22:34–37
6.
go back to reference Redmond DM, Rivner MH (1988) False positive electrodiagnostic tests in carpal tunnel syndrome. Muscle Nerve 11:511–517PubMed Redmond DM, Rivner MH (1988) False positive electrodiagnostic tests in carpal tunnel syndrome. Muscle Nerve 11:511–517PubMed
7.
go back to reference Homan MM, Franzblau A, Werner RA, Albers JW, Armstrong TJ, Bromberg MB (1999) Agreement between symptom surveys, physical examination procedures and electrodiagnostic findings for the carpal tunnel syndrome. Scand J Work Environ Health 25:115–124PubMed Homan MM, Franzblau A, Werner RA, Albers JW, Armstrong TJ, Bromberg MB (1999) Agreement between symptom surveys, physical examination procedures and electrodiagnostic findings for the carpal tunnel syndrome. Scand J Work Environ Health 25:115–124PubMed
8.
go back to reference Buchthal F, Rosenfalck A (1971) Sensory conduction from digit to palm and from palm to wrist in the carpal tunnel syndrome. J Neurol Neurosurg Psychiatry 34:243–252PubMed Buchthal F, Rosenfalck A (1971) Sensory conduction from digit to palm and from palm to wrist in the carpal tunnel syndrome. J Neurol Neurosurg Psychiatry 34:243–252PubMed
9.
go back to reference Cioni R, Passero S, Paradiso C, Giannini F, Battistin N et al (1989) Diagnostic specificity of sensory and motor nerve conduction variables in early detection of carpal tunnel syndrome. J Neurol 236:208–213PubMed Cioni R, Passero S, Paradiso C, Giannini F, Battistin N et al (1989) Diagnostic specificity of sensory and motor nerve conduction variables in early detection of carpal tunnel syndrome. J Neurol 236:208–213PubMed
10.
go back to reference Johnson EW, Sipski M, Lammertse T (1987) Median and radial latencies to digit I: normal values and usefulness in carpal tunnel syndrome. Arch Phys Med Rehabil 68:140–141PubMed Johnson EW, Sipski M, Lammertse T (1987) Median and radial latencies to digit I: normal values and usefulness in carpal tunnel syndrome. Arch Phys Med Rehabil 68:140–141PubMed
11.
go back to reference Kimura J (1979) The carpal tunnel syndrome: localization of conduction abnormalities within the distal segment of the median nerve. Brain 102:619–635PubMed Kimura J (1979) The carpal tunnel syndrome: localization of conduction abnormalities within the distal segment of the median nerve. Brain 102:619–635PubMed
12.
go back to reference Stevens JC (1987) The electrodiagnosis of carpal tunnel syndrome. Muscle Nerve 10:99–113PubMed Stevens JC (1987) The electrodiagnosis of carpal tunnel syndrome. Muscle Nerve 10:99–113PubMed
13.
go back to reference Uncini A, Lange DJ, Solomon M, Soliven B, Meer J et al (1989) Ring finger testing in carpal tunnel syndrome: a comparative study of diagnostic utility. Muscle Nerve 12:735–741PubMed Uncini A, Lange DJ, Solomon M, Soliven B, Meer J et al (1989) Ring finger testing in carpal tunnel syndrome: a comparative study of diagnostic utility. Muscle Nerve 12:735–741PubMed
14.
go back to reference Uncini A, Muzio AD, Awad J, Manente G, Tafuro M et al (1993) Sensitivity of three median-to-ulnar comparative tests in diagnosis of mild carpal tunnel syndrome. Muscle Nerve 16:1366–1373PubMed Uncini A, Muzio AD, Awad J, Manente G, Tafuro M et al (1993) Sensitivity of three median-to-ulnar comparative tests in diagnosis of mild carpal tunnel syndrome. Muscle Nerve 16:1366–1373PubMed
15.
go back to reference Robinson LR, Micklesen PJ, Wang L (2000) Optimizing the number of tests for carpal tunnel syndrome. Muscle Nerve 23:1880–1882CrossRefPubMed Robinson LR, Micklesen PJ, Wang L (2000) Optimizing the number of tests for carpal tunnel syndrome. Muscle Nerve 23:1880–1882CrossRefPubMed
16.
go back to reference AAEM Quality Assurance Committee (1993) Literature review of the usefulness of nerve conduction studies and electromyography for the evaluation of patients with carpal tunnel syndrome. Muscle Nerve 16:1392–1414PubMed AAEM Quality Assurance Committee (1993) Literature review of the usefulness of nerve conduction studies and electromyography for the evaluation of patients with carpal tunnel syndrome. Muscle Nerve 16:1392–1414PubMed
17.
go back to reference Padua L, Lo Monaco M, Gregori B, Valente EM, Padua R et al (1997) Neurophysiological classification and sensitivity in 500 carpal tunnel syndrome hands. Acta Neurol Scand 96:211–217PubMed Padua L, Lo Monaco M, Gregori B, Valente EM, Padua R et al (1997) Neurophysiological classification and sensitivity in 500 carpal tunnel syndrome hands. Acta Neurol Scand 96:211–217PubMed
18.
go back to reference Kemble F (1968) Electrodiagnosis in carpal tunnel syndrome. J Neurol Neurosurg Psychiatry 31:23–27PubMed Kemble F (1968) Electrodiagnosis in carpal tunnel syndrome. J Neurol Neurosurg Psychiatry 31:23–27PubMed
19.
go back to reference Monga TN, Shanks GL, Poole BJ (1985) Sensory palmar stimulation in the diagnosis of carpal tunnel syndrome. Arch Phys Med Rehabil 66:598–600PubMed Monga TN, Shanks GL, Poole BJ (1985) Sensory palmar stimulation in the diagnosis of carpal tunnel syndrome. Arch Phys Med Rehabil 66:598–600PubMed
20.
go back to reference Cruz Martinez A (1991) Diagnostic yield of different electrophysiological methods in carpal tunnel syndrome. Muscle Nerve 14:183–184PubMed Cruz Martinez A (1991) Diagnostic yield of different electrophysiological methods in carpal tunnel syndrome. Muscle Nerve 14:183–184PubMed
21.
go back to reference Charles N, Vial C, Chauplannaz G, Bady B (1990) Clinical validation of antidromic stimulation of ring finger in early diagnosis of mild carpal tunnel syndrome. Electroencephalogr Clin Neurophysiol 76:142–147CrossRefPubMed Charles N, Vial C, Chauplannaz G, Bady B (1990) Clinical validation of antidromic stimulation of ring finger in early diagnosis of mild carpal tunnel syndrome. Electroencephalogr Clin Neurophysiol 76:142–147CrossRefPubMed
22.
go back to reference Pease WS, Cannel CD, Johnson EW (1989) Median to radial difference in mild carpal tunnel syndrome. Muscle Nerve 12:905–909PubMed Pease WS, Cannel CD, Johnson EW (1989) Median to radial difference in mild carpal tunnel syndrome. Muscle Nerve 12:905–909PubMed
Metadata
Title
Comparison of sensory conduction techniques in the diagnosis of mild idiopathic carpal tunnel syndrome: which finger, which test?
Authors
Serpil Demirci
Birkan Sonel
Publication date
01-07-2004
Publisher
Springer-Verlag
Published in
Rheumatology International / Issue 4/2004
Print ISSN: 0172-8172
Electronic ISSN: 1437-160X
DOI
https://doi.org/10.1007/s00296-003-0351-y

Other articles of this Issue 4/2004

Rheumatology International 4/2004 Go to the issue