Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 5/2017

01-05-2017 | Clinical Investigation

Reduction of Radiation Exposure Using Dynamic Trace Digital Angiography and Spot Fluoroscopy During Adrenal Venous Sampling

Authors: Satoru Morita, Kenji Endo, Shingo Suzaki, Umiko Ishizaki, Hiroshi Yamazaki, Yu Nishina, Shuji Sakai

Published in: CardioVascular and Interventional Radiology | Issue 5/2017

Login to get access

Abstract

Purpose

To compare radiation exposure of adrenal venous sampling (AVS) using dynamic trace digital angiography (DTDA) and spot fluoroscopy with that using conventional methods.

Materials and Methods

AVS was performed in 11 patients using DTDA and spot fluoroscopy (Group A) and 11 patients using conventional digital subtraction angiography (DSA) with collimation (Group B). Radiation exposure and image quality of adrenal venography using a five-point scale were compared between the groups.

Results

The acquisition dose–area product (DAP) using DTDA and fluoro-DAP using spot fluoroscopy in Group A were lower than those using conventional DSA (5.3 ± 3.7 vs. 29.1 ± 20.1 Gy cm2, p < 0.001) and collimation (33.3 ± 22.9 vs. 59.1 ± 35.7 Gy cm2, p = 0.088) in Group B. The total DAP in Group A was significantly lower than that in Group B (38.6 ± 25.9 vs. 88.2 ± 53.6 Gy cm2, p = 0.006). The peak skin dose for patients and operator radiation exposure in Group A were significantly lower than those in Group B (403 ± 340 vs. 771 ± 416 mGy, p = 0.030, and 17.1 ± 14.8 vs. 36.6 ± 21.7 μSv, p = 0.013). The image quality of DTDA (4.4 ± 0.6) was significantly higher than that of digital angiography (3.8 ± 0.9, p = 0.011) and equivalent to that of DSA (4.3 ± 0.8, p = 0.651).

Conclusions

Radiation exposure during AVS can be reduced by approximately half for both patients and operators by using DTDA and spot fluoroscopy without sacrificing image quality.
Literature
1.
go back to reference Nishikawa T, Omura M, Satoh F, Task Force Committee on Primary Aldosteronism, The Japan Endocrine Society, et al. Guidelines for the diagnosis and treatment of primary aldosteronism—the Japan Endocrine Society 2009. Endocr J. 2011;58(9):711–21.CrossRefPubMed Nishikawa T, Omura M, Satoh F, Task Force Committee on Primary Aldosteronism, The Japan Endocrine Society, et al. Guidelines for the diagnosis and treatment of primary aldosteronism—the Japan Endocrine Society 2009. Endocr J. 2011;58(9):711–21.CrossRefPubMed
2.
go back to reference Funder JW, Carey RM, Fardella C, Endocrine Society, et al. Case detection, diagnosis, and treatment of patients with primary aldosteronism: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2008;93(9):3266–81.CrossRefPubMed Funder JW, Carey RM, Fardella C, Endocrine Society, et al. Case detection, diagnosis, and treatment of patients with primary aldosteronism: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2008;93(9):3266–81.CrossRefPubMed
3.
go back to reference Rossi GP, Auchus RJ, Brown M, et al. An expert consensus statement on use of adrenal vein sampling for the subtyping of primary aldosteronism. Hypertension. 2014;63(1):151–60.CrossRefPubMed Rossi GP, Auchus RJ, Brown M, et al. An expert consensus statement on use of adrenal vein sampling for the subtyping of primary aldosteronism. Hypertension. 2014;63(1):151–60.CrossRefPubMed
4.
go back to reference Nishikawa T, Matsuzawa Y, Saito J, Omura M. Is it possible to extirpate cardiovascular events in primary aldosteronism after surgical treatment. Jpn Clin Med. 2010;30(1):21–3.CrossRef Nishikawa T, Matsuzawa Y, Saito J, Omura M. Is it possible to extirpate cardiovascular events in primary aldosteronism after surgical treatment. Jpn Clin Med. 2010;30(1):21–3.CrossRef
5.
go back to reference Satani N, Ota H, Seiji K, et al. Intra-adrenal aldosterone secretion: segmental adrenal venous sampling for localization. Radiology. 2016;278(1):265–74.CrossRefPubMed Satani N, Ota H, Seiji K, et al. Intra-adrenal aldosterone secretion: segmental adrenal venous sampling for localization. Radiology. 2016;278(1):265–74.CrossRefPubMed
6.
go back to reference Morita S, Yamazaki H, Sonoyama Y, Nishina Y, Ichihara A, Sakai S. Successful adrenal venous sampling by non-experts with reference to CT images. Cardiovasc Intervent Radiol. 2016;39(7):1001–6.CrossRefPubMed Morita S, Yamazaki H, Sonoyama Y, Nishina Y, Ichihara A, Sakai S. Successful adrenal venous sampling by non-experts with reference to CT images. Cardiovasc Intervent Radiol. 2016;39(7):1001–6.CrossRefPubMed
7.
go back to reference Busser WM, Arntz MJ, Jenniskens SF, et al. Image registration of cone-beam computer tomography and preprocedural computer tomography aids in localization of adrenal veins and decreasing radiation dose in adrenal vein sampling. Cardiovasc Intervent Radiol. 2015;38(4):993–7.CrossRefPubMed Busser WM, Arntz MJ, Jenniskens SF, et al. Image registration of cone-beam computer tomography and preprocedural computer tomography aids in localization of adrenal veins and decreasing radiation dose in adrenal vein sampling. Cardiovasc Intervent Radiol. 2015;38(4):993–7.CrossRefPubMed
8.
go back to reference McAdams HP, Samei E, Dobbins J 3rd, Tourassi GD, Ravin CE. Recent advances in chest radiography. Radiology. 2006;241(3):663–83.CrossRefPubMed McAdams HP, Samei E, Dobbins J 3rd, Tourassi GD, Ravin CE. Recent advances in chest radiography. Radiology. 2006;241(3):663–83.CrossRefPubMed
9.
go back to reference Borota L, Patz A, Uppsala SE, Zoetermeer NL. Spot Fluoro—A novel innovative approach to reduce the dose in interventional procedures—advantages and drawbacks. ECR 2014 C-1428. Borota L, Patz A, Uppsala SE, Zoetermeer NL. Spot Fluoro—A novel innovative approach to reduce the dose in interventional procedures—advantages and drawbacks. ECR 2014 C-1428.
10.
go back to reference Miller DL, Vañó E, Bartal G, Cardiovascular and Interventional Radiology Society of Europe, Society of Interventional Radiology, et al. Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. J Vasc Interv Radiol. 2010;21(5):607–15.CrossRefPubMed Miller DL, Vañó E, Bartal G, Cardiovascular and Interventional Radiology Society of Europe, Society of Interventional Radiology, et al. Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. J Vasc Interv Radiol. 2010;21(5):607–15.CrossRefPubMed
11.
go back to reference Stecker MS, Balter S, Towbin RB, SIR Safety and Health Committee, CIRSE Standards of Practice Committee, et al. Guidelines for patient radiation dose management. J Vasc Interv Radiol. 2009;20(7 Suppl):S263–73.CrossRefPubMed Stecker MS, Balter S, Towbin RB, SIR Safety and Health Committee, CIRSE Standards of Practice Committee, et al. Guidelines for patient radiation dose management. J Vasc Interv Radiol. 2009;20(7 Suppl):S263–73.CrossRefPubMed
Metadata
Title
Reduction of Radiation Exposure Using Dynamic Trace Digital Angiography and Spot Fluoroscopy During Adrenal Venous Sampling
Authors
Satoru Morita
Kenji Endo
Shingo Suzaki
Umiko Ishizaki
Hiroshi Yamazaki
Yu Nishina
Shuji Sakai
Publication date
01-05-2017
Publisher
Springer US
Published in
CardioVascular and Interventional Radiology / Issue 5/2017
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-017-1567-7

Other articles of this Issue 5/2017

CardioVascular and Interventional Radiology 5/2017 Go to the issue