Skip to main content
Top
Published in: Aesthetic Plastic Surgery 3/2022

16-11-2021 | Blepharoplasty | Original Article

Vectra 3D Simulation in Lower Eyelid Blepharoplasty: How Accurate is it?

Authors: Ricardo E. Miranda, Suzana Matayoshi

Published in: Aesthetic Plastic Surgery | Issue 3/2022

Login to get access

Abstract

Background

Estimating the volume of fat to be resected during lower lid blepharoplasty can be challenging. While the excess fat is clearly visible in the upright position, it retracts into the orbital cavity when the patient is in decubitus. Several tools have been developed to predict the volume required for adequate outcomes and to reduce the risk of complications. Among these, 3D photography, in addition to being noninvasive, radiation-free, portable and relatively inexpensive, can be used to make simulations.

Objective

To assess the level of agreement between Vectra H1 camera simulations and the outcome of lower eyelid blepharoplasties with volume removal based on these simulations.

Methods

Preoperatively, a 3D camera and simulation software (Vectra H1, Canfield Imaging Systems) was used to estimate the fat pad volume to be resected from the lower eyelids in a sample of 35 patients (female n = 34) aged 55 years on average. Following the procedure, the patients were photographed at 1, 3 and 6 months and the outcome was compared to the simulation.

Results

The agreement between the simulated volume and the intraoperative volume was high. While the difference between the postoperative volume and the simulated volume decreased over time, at 6 months the actual volume was still 0.30 mL (right eye) and 0.24 mL (left eye) larger than the simulated volume.

Conclusions

A systematic and significant difference was found between the simulation volume and the postoperative volume. The low level of agreement observed suggests that the accuracy of the tested software is insufficient for reliable simulations.

Level of Evidence IV

This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.​springer.​com/​00266.
Literature
1.
go back to reference Miller TR (2016) Long-term 3-dimensional volume assessment after fat repositioning lower blepharoplasty. JAMA Fac Plast Surg 18(2):108–113CrossRef Miller TR (2016) Long-term 3-dimensional volume assessment after fat repositioning lower blepharoplasty. JAMA Fac Plast Surg 18(2):108–113CrossRef
2.
go back to reference Drolet BC, Sullivan PK (2014) Evidence-based medicine: blepharoplasty. Plast Reconstr Surg 133(5):1195–1205CrossRef Drolet BC, Sullivan PK (2014) Evidence-based medicine: blepharoplasty. Plast Reconstr Surg 133(5):1195–1205CrossRef
3.
go back to reference Castanares S (1951) Blepharoplasty for herniated intraorbital fat; anatomical basis for a new approach. Plast Reconstr Surg (1946) 8(1):46–58CrossRef Castanares S (1951) Blepharoplasty for herniated intraorbital fat; anatomical basis for a new approach. Plast Reconstr Surg (1946) 8(1):46–58CrossRef
4.
go back to reference Garcia RE, McCollough EG (2006) Transcutaneous lower eyelid blepharoplasty with fat excision: a shift-resisting paradigm. Arch Fac Plast Surg 8(6):374–380CrossRef Garcia RE, McCollough EG (2006) Transcutaneous lower eyelid blepharoplasty with fat excision: a shift-resisting paradigm. Arch Fac Plast Surg 8(6):374–380CrossRef
5.
go back to reference Zoumalan CI, Roostaeian J (2016) Simplifying blepharoplasty. Plast Reconstr Surg 137(1):196e–213eCrossRef Zoumalan CI, Roostaeian J (2016) Simplifying blepharoplasty. Plast Reconstr Surg 137(1):196e–213eCrossRef
6.
go back to reference Collar RM, Lyford-Pike S, Byrne P (2013) Algorithmic approach to lower lid blepharoplasty. Fac Plast Surg 29(1):32–39CrossRef Collar RM, Lyford-Pike S, Byrne P (2013) Algorithmic approach to lower lid blepharoplasty. Fac Plast Surg 29(1):32–39CrossRef
7.
go back to reference Massry GG (2010) Comprehensive lower eyelid rejuvenation. Fac Plast Surg 26(3):209–221CrossRef Massry GG (2010) Comprehensive lower eyelid rejuvenation. Fac Plast Surg 26(3):209–221CrossRef
8.
go back to reference Hashem AM, Couto RA, Waltzman JT, Drake RL, Zins JE (2017) Evidence-based medicine: a graded approach to lower lid blepharoplasty. Plast Reconstr Surg 139(1):139e-e150CrossRef Hashem AM, Couto RA, Waltzman JT, Drake RL, Zins JE (2017) Evidence-based medicine: a graded approach to lower lid blepharoplasty. Plast Reconstr Surg 139(1):139e-e150CrossRef
9.
go back to reference Kossler AL, Peng GL, Yoo DB, Azizzadeh B, Massry GG (2018) Current trends in upper and lower eyelid blepharoplasty among American society of ophthalmic plastic and reconstructive surgery members. Ophthalmic Plast Reconstr Surg 34(1):37–42CrossRef Kossler AL, Peng GL, Yoo DB, Azizzadeh B, Massry GG (2018) Current trends in upper and lower eyelid blepharoplasty among American society of ophthalmic plastic and reconstructive surgery members. Ophthalmic Plast Reconstr Surg 34(1):37–42CrossRef
10.
go back to reference Pezeshk RA, Sieber DA, Rohrich RJ (2017) The six-step lower blepharoplasty: using fractionated fat to enhance blending of the lid-cheek junction. Plast Reconstr Surg 139(6):1381–1383CrossRef Pezeshk RA, Sieber DA, Rohrich RJ (2017) The six-step lower blepharoplasty: using fractionated fat to enhance blending of the lid-cheek junction. Plast Reconstr Surg 139(6):1381–1383CrossRef
11.
go back to reference Smith CB, Waite PD (2016) Lower transcutaneous blepharoplasty. Atlas Oral Maxillofac Surg Clin North Am 24(2):135–145CrossRef Smith CB, Waite PD (2016) Lower transcutaneous blepharoplasty. Atlas Oral Maxillofac Surg Clin North Am 24(2):135–145CrossRef
12.
go back to reference Schwarcz RM, Kotlus B (2015) Complications of lower blepharoplasty and midface lifting. Clin Plast Surg 42(1):63–71CrossRef Schwarcz RM, Kotlus B (2015) Complications of lower blepharoplasty and midface lifting. Clin Plast Surg 42(1):63–71CrossRef
13.
go back to reference Lelli GJ Jr, Lisman RD (2010) Blepharoplasty complications. Plast Reconstr Surg 125(3):1007–1017CrossRef Lelli GJ Jr, Lisman RD (2010) Blepharoplasty complications. Plast Reconstr Surg 125(3):1007–1017CrossRef
14.
go back to reference Perez-Carrasco JA, Acha B, Gomez-Cia T, Lopez-Garcia RA, Delgado C, Serrano C (2015) 3D surgical planning in patients affected by lipodystrophy. Comput Med Imaging Gr 40:128–137CrossRef Perez-Carrasco JA, Acha B, Gomez-Cia T, Lopez-Garcia RA, Delgado C, Serrano C (2015) 3D surgical planning in patients affected by lipodystrophy. Comput Med Imaging Gr 40:128–137CrossRef
15.
go back to reference Tzou CH, Artner NM, Pona I, Hold A, Placheta E, Kropatsch WG et al (2014) Comparison of three-dimensional surface-imaging systems. J Plast Reconstr Aesthet Surg 67(4):489–497CrossRef Tzou CH, Artner NM, Pona I, Hold A, Placheta E, Kropatsch WG et al (2014) Comparison of three-dimensional surface-imaging systems. J Plast Reconstr Aesthet Surg 67(4):489–497CrossRef
16.
go back to reference Camp MC, Wong WW, Filip Z, Carter CS, Gupta SC (2011) A quantitative analysis of periorbital aging with three-dimensional surface imaging. J Plast Reconstr Aesthet Surg 64(2):148–154CrossRef Camp MC, Wong WW, Filip Z, Carter CS, Gupta SC (2011) A quantitative analysis of periorbital aging with three-dimensional surface imaging. J Plast Reconstr Aesthet Surg 64(2):148–154CrossRef
17.
go back to reference Choppin SB, Wheat JS, Gee M, Goyal A (2016) The accuracy of breast volume measurement methods: a systematic review. Breast 28:121–129CrossRef Choppin SB, Wheat JS, Gee M, Goyal A (2016) The accuracy of breast volume measurement methods: a systematic review. Breast 28:121–129CrossRef
18.
go back to reference Camison L, Bykowski M, Lee WW, Carlson JC, Roosenboom J, Goldstein JA et al (2018) Validation of the Vectra H1 portable three-dimensional photogrammetry system for facial imaging. Int J Oral Maxillofac Surg 47(3):403–410CrossRef Camison L, Bykowski M, Lee WW, Carlson JC, Roosenboom J, Goldstein JA et al (2018) Validation of the Vectra H1 portable three-dimensional photogrammetry system for facial imaging. Int J Oral Maxillofac Surg 47(3):403–410CrossRef
19.
go back to reference Honrado CP, Larrabee WF Jr (2004) Update in three-dimensional imaging in facial plastic surgery. Curr Opin Otolaryngol Head Neck Surg 12(4):327–331CrossRef Honrado CP, Larrabee WF Jr (2004) Update in three-dimensional imaging in facial plastic surgery. Curr Opin Otolaryngol Head Neck Surg 12(4):327–331CrossRef
20.
go back to reference Jodeh DS, Rottgers SA (2019) High-fidelity anthropometric facial measurements can be obtained from a single stereophotograph from the vectra H1 3-dimensional camera. Cleft Palate Craniofac J 56(9):1164–1170CrossRef Jodeh DS, Rottgers SA (2019) High-fidelity anthropometric facial measurements can be obtained from a single stereophotograph from the vectra H1 3-dimensional camera. Cleft Palate Craniofac J 56(9):1164–1170CrossRef
21.
go back to reference Hoeffelin H, Jacquemin D, Defaweux V, Nizet JL (2014) A methodological evaluation of volumetric measurement techniques including three-dimensional imaging in breast surgery. Biomed Res Int. 573249 Hoeffelin H, Jacquemin D, Defaweux V, Nizet JL (2014) A methodological evaluation of volumetric measurement techniques including three-dimensional imaging in breast surgery. Biomed Res Int. 573249
22.
go back to reference de Menezes M, Rosati R, Ferrario VF, Sforza C (2010) Accuracy and reproducibility of a 3-dimensional stereophotogrammetric imaging system. J Oral Maxillofac Surg 68(9):2129–2135CrossRef de Menezes M, Rosati R, Ferrario VF, Sforza C (2010) Accuracy and reproducibility of a 3-dimensional stereophotogrammetric imaging system. J Oral Maxillofac Surg 68(9):2129–2135CrossRef
23.
go back to reference Hermans DJ, Maal TJ, Berge SJ, van der Vleuten CJ (2014) Three-dimensional stereophotogrammetry: a novel method in volumetric measurement of infantile hemangioma. Pediatr Dermatol 31(1):118–122CrossRef Hermans DJ, Maal TJ, Berge SJ, van der Vleuten CJ (2014) Three-dimensional stereophotogrammetry: a novel method in volumetric measurement of infantile hemangioma. Pediatr Dermatol 31(1):118–122CrossRef
24.
go back to reference van der Meer WJ, Dijkstra PU, Visser A, Vissink A, Ren Y (2014) Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner. Br J Oral Maxillofac Surg 52(10):922–927CrossRef van der Meer WJ, Dijkstra PU, Visser A, Vissink A, Ren Y (2014) Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner. Br J Oral Maxillofac Surg 52(10):922–927CrossRef
25.
go back to reference Wat H, Kawa NI, Anderson RR, Avram MM (2020) Precise volumetric quantification using 3D stereophotogrammetry in procedural and surgical dermatology. J Am Acad Dermatol Wat H, Kawa NI, Anderson RR, Avram MM (2020) Precise volumetric quantification using 3D stereophotogrammetry in procedural and surgical dermatology. J Am Acad Dermatol
26.
go back to reference Alsarraf R (2000) Outcomes research in facial plastic surgery: a review and new directions. Aesthet Plast Surg 24(3):192–197CrossRef Alsarraf R (2000) Outcomes research in facial plastic surgery: a review and new directions. Aesthet Plast Surg 24(3):192–197CrossRef
27.
go back to reference Giavarina D (2015) Understanding bland altman analysis. Biochem Med (Zagreb) 25(2):141–151CrossRef Giavarina D (2015) Understanding bland altman analysis. Biochem Med (Zagreb) 25(2):141–151CrossRef
28.
go back to reference Cristel RT, Caughlin BP (2020) Lower blepharoplasty three-dimensional volume assessment after fat pad transposition and concomitant fat grafting. Fac Plast Surg 36(4):478–483CrossRef Cristel RT, Caughlin BP (2020) Lower blepharoplasty three-dimensional volume assessment after fat pad transposition and concomitant fat grafting. Fac Plast Surg 36(4):478–483CrossRef
29.
go back to reference Donath AS, Glasgold RA, Meier J, Glasgold MJ (2010) Quantitative evaluation of volume augmentation in the tear trough with a hyaluronic acid-based filler: a three-dimensional analysis. Plast Reconstr Surg 125(5):1515–1522CrossRef Donath AS, Glasgold RA, Meier J, Glasgold MJ (2010) Quantitative evaluation of volume augmentation in the tear trough with a hyaluronic acid-based filler: a three-dimensional analysis. Plast Reconstr Surg 125(5):1515–1522CrossRef
30.
go back to reference Lubbers HT, Medinger L, Kruse AL, Gratz KW, Obwegeser JA, Matthews F (2012) The influence of involuntary facial movements on craniofacial anthropometry: a survey using a three-dimensional photographic system. Br J Oral Maxillofac Surg 50(2):171–175CrossRef Lubbers HT, Medinger L, Kruse AL, Gratz KW, Obwegeser JA, Matthews F (2012) The influence of involuntary facial movements on craniofacial anthropometry: a survey using a three-dimensional photographic system. Br J Oral Maxillofac Surg 50(2):171–175CrossRef
31.
go back to reference Maal TJ, Verhamme LM, van Loon B, Plooij JM, Rangel FA, Kho A et al (2011) Variation of the face in rest using 3D stereophotogrammetry. Int J Oral Maxillofac Surg 40(11):1252–1257CrossRef Maal TJ, Verhamme LM, van Loon B, Plooij JM, Rangel FA, Kho A et al (2011) Variation of the face in rest using 3D stereophotogrammetry. Int J Oral Maxillofac Surg 40(11):1252–1257CrossRef
32.
go back to reference Gibelli D, Pucciarelli V, Cappella A, Dolci C, Sforza C (2018) Are portable stereophotogrammetric devices reliable in facial imaging? A validation study of Vectra H1 device. J Oral Maxillofac Surg 76(8):1772–1784CrossRef Gibelli D, Pucciarelli V, Cappella A, Dolci C, Sforza C (2018) Are portable stereophotogrammetric devices reliable in facial imaging? A validation study of Vectra H1 device. J Oral Maxillofac Surg 76(8):1772–1784CrossRef
33.
go back to reference Hyer JN, Murta F, Juniat VAR, Ezra DG (2021) Validating three-dimensional imaging for volumetric assessment of periorbital soft tissue. Orbit 40(1):9–17CrossRef Hyer JN, Murta F, Juniat VAR, Ezra DG (2021) Validating three-dimensional imaging for volumetric assessment of periorbital soft tissue. Orbit 40(1):9–17CrossRef
34.
go back to reference White JD, Ortega-Castrillon A, Virgo C, Indencleef K, Hoskens H, Shriver MD et al (2020) Sources of variation in the 3dMDface and vectra H1 3D facial imaging systems. Sci Rep 10(1):4443CrossRef White JD, Ortega-Castrillon A, Virgo C, Indencleef K, Hoskens H, Shriver MD et al (2020) Sources of variation in the 3dMDface and vectra H1 3D facial imaging systems. Sci Rep 10(1):4443CrossRef
Metadata
Title
Vectra 3D Simulation in Lower Eyelid Blepharoplasty: How Accurate is it?
Authors
Ricardo E. Miranda
Suzana Matayoshi
Publication date
16-11-2021
Publisher
Springer US
Published in
Aesthetic Plastic Surgery / Issue 3/2022
Print ISSN: 0364-216X
Electronic ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-021-02661-1

Other articles of this Issue 3/2022

Aesthetic Plastic Surgery 3/2022 Go to the issue