Skip to main content
Top
Published in: International Orthopaedics 1/2019

01-01-2019 | Original Paper

Computed tomography evaluation of total knee arthroplasty implants position after two different surgical methods of implantation

Authors: Francesco Benazzo, Stefano Marco Paolo Rossi, Gianmarco Danesino, Catherine Klersy, Simone Perelli, Matteo Ghiara

Published in: International Orthopaedics | Issue 1/2019

Login to get access

Abstract

Purpose

The objectives of this study were to determine the reliability of a novel method of measuring the rotational alignment of an anatomical tibial tray, the difference in the rotational alignment of the femoral and tibial component according to pure measured resection or blended technique with tensor, and, finally, the difference in terms of clinical results according to the two different methods.

Patients and methods

We performed a total of 60 consecutive TKAs: 30 according to pure measured resection and 30 according to blended technique with tensor (FuZion®). Clinical scores and CT scan were done at six months to measure patient’s outcome and prosthetic components rotation.

Results

The method of measurement of tibial tray had high agreement between different radiological observers. Mean external rotation alignment of the femur was 2.7° in standard group and 0.5° in the FuZion® group. For all clinical indices, we observed a large and significant improvement at follow-up, better in blended technique group, but without a clear superiority, and no statistically significant difference was evident between the two groups. At follow-up, HSS was to 89.7 in the FuZion® group and 89.0 in the standard group, KSS (clinical) was 92.6 in and 91.3 respectively, and KSS (Functional) was 91.0 in the FuZion® group and 87.6 in the standard group.

Conclusions

Our CT measurement method is reliable and reproducible. All patients operated with this personalized knee system design obtained excellent results; the customization of femoral rotation with a blended technique is, probably, the key to optimize the outcomes and achieve the state of forgotten knee.
Literature
1.
go back to reference Petersen W, Rembitzki IV, Brüggemann GP, Ellermann A, Best R, Koppenburg AG, Liebau C (2014) Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 38(2):319–328CrossRefPubMed Petersen W, Rembitzki IV, Brüggemann GP, Ellermann A, Best R, Koppenburg AG, Liebau C (2014) Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 38(2):319–328CrossRefPubMed
3.
go back to reference Berger RA, Rubash HE (2001) Rotational instability and malrotation after total knee arthroplasty. Orthopedic Clinics of North America N 4:639–647CrossRef Berger RA, Rubash HE (2001) Rotational instability and malrotation after total knee arthroplasty. Orthopedic Clinics of North America N 4:639–647CrossRef
4.
go back to reference Boldt JG, Stiehl JB, Hodler J, Zanetti M, Munzinger U (2006) Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty. Int Orthop 30(5):420–425CrossRefPubMedPubMedCentral Boldt JG, Stiehl JB, Hodler J, Zanetti M, Munzinger U (2006) Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty. Int Orthop 30(5):420–425CrossRefPubMedPubMedCentral
8.
go back to reference Ghiara M, Combi A, Perticarini L, Rossi SMP, Benazzo F (2013) Patient reported outcome measures in the new persona total knee arthroplasty. J Orthop Trauma 14(Suppl 1):S109–S110 Ghiara M, Combi A, Perticarini L, Rossi SMP, Benazzo F (2013) Patient reported outcome measures in the new persona total knee arthroplasty. J Orthop Trauma 14(Suppl 1):S109–S110
9.
go back to reference Ghiara M, Combi A, Perticarini L, Rossi SMP, Benazzo F (2013) Short term follow-up in the new persona total knee arthroplasty. J Orthop Trauma 14(Suppl 1):S111 Ghiara M, Combi A, Perticarini L, Rossi SMP, Benazzo F (2013) Short term follow-up in the new persona total knee arthroplasty. J Orthop Trauma 14(Suppl 1):S111
11.
go back to reference Sarmah SS, Patel S, Hossain FS, Haddad FS (2012) The radiological assessment of total and unicompartmental knee replacements. J Bone Joint Surg (Br) 94-B:1321–1329CrossRef Sarmah SS, Patel S, Hossain FS, Haddad FS (2012) The radiological assessment of total and unicompartmental knee replacements. J Bone Joint Surg (Br) 94-B:1321–1329CrossRef
14.
go back to reference Olcott CW, Scott RD (2000) A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplast 15(1):22–26CrossRef Olcott CW, Scott RD (2000) A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplast 15(1):22–26CrossRef
18.
go back to reference Scott RD (2013) Femoral and tibial component rotation in total knee arthroplasty. Bone Joint J 95-B(Supple A):140–143CrossRefPubMed Scott RD (2013) Femoral and tibial component rotation in total knee arthroplasty. Bone Joint J 95-B(Supple A):140–143CrossRefPubMed
Metadata
Title
Computed tomography evaluation of total knee arthroplasty implants position after two different surgical methods of implantation
Authors
Francesco Benazzo
Stefano Marco Paolo Rossi
Gianmarco Danesino
Catherine Klersy
Simone Perelli
Matteo Ghiara
Publication date
01-01-2019
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 1/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-4180-8

Other articles of this Issue 1/2019

International Orthopaedics 1/2019 Go to the issue