Abstract

Introduction

To date, only a few studies have compared radial head prostheses (RHP) and their different anchoring principles. The aim of this study was to characterize concomitant injuries, necessary adjuvant procedures, complications, and radiological findings after implantation of two different types of RHP.

Methods

Sixty-six patients with radial head fractures were treated with MoPyC (Tornier/France, 50 mm stem, monopolar) or SBI rHead prostheses (Small Bone Innovations/USA, 22-mm stem, bipolar) and followed up over 42 months (16–64 months). Primary objective was the detection of different loosening and explantation rates. In addition to the revision rate and the reasons for revision, we also used radiological findings to assess the dynamics of lysis phenomena.

Results

Thirty-five patients (mean age 48 years; 22–73 years) were treated with the MoPyC, and 31 patients (mean age 47 years, 19–69 years) with the rHead prosthesis. Of these, 98% had a Mason 3 or 4 type of radial head fracture, and 94% showed concomitant injuries, which were addressed in 89% of cases by adjuvant procedures. The surgical revision rate was 20% (rHead 23%; MoPyC 18%). Significantly more of the rHead prostheses had to be explanted compared to MoPyC prostheses because of painful loosening (16% vs. 3%; p = 0.029). Predictors of subsequent loosening were significant radiolucent lines in the RHP over the first six months and an increase in width by two and a half times within the first 50 days after implantation.

Conclusion

Complex radial head fractures are frequent and difficult to treat. The monopolar long-stemmed prosthesis showed significantly lower rates of painful loosening and explanation rates than the bipolar short-stemmed prosthesis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Itamura J, Roidis N, Mirzayan R, Vaishnav S, Learch T, Shean C (2005) Radial head fractures: MRI evaluation of associated injuries. J Shoulder Elb Surg 14(4):421–424CrossRef Itamura J, Roidis N, Mirzayan R, Vaishnav S, Learch T, Shean C (2005) Radial head fractures: MRI evaluation of associated injuries. J Shoulder Elb Surg 14(4):421–424CrossRef
2.
go back to reference Morrey BF, An K-N (2005) Stability of the elbow: osseous constraints. J Shoulder Elb Surg 14(1):S174–S178CrossRef Morrey BF, An K-N (2005) Stability of the elbow: osseous constraints. J Shoulder Elb Surg 14(1):S174–S178CrossRef
3.
go back to reference Schmidt-Horlohe K, Siebenlist S, Stöckle U, Pichl J, Hoffmann R (2011) Fractures of the radial head and neck. Zeitschrift fur Orthopadie und Unfallchirurgie 149(6):e69–e86 quiz e87–68CrossRefPubMed Schmidt-Horlohe K, Siebenlist S, Stöckle U, Pichl J, Hoffmann R (2011) Fractures of the radial head and neck. Zeitschrift fur Orthopadie und Unfallchirurgie 149(6):e69–e86 quiz e87–68CrossRefPubMed
5.
go back to reference Al-Burdeni S, Abuodeh Y, Ibrahim T, Ahmed G (2015) Open reduction and internal fixation versus radial head arthroplasty in the treatment of adult closed comminuted radial head fractures (modified Mason type III and IV). Int Orthop 39(8):1659–1664CrossRefPubMed Al-Burdeni S, Abuodeh Y, Ibrahim T, Ahmed G (2015) Open reduction and internal fixation versus radial head arthroplasty in the treatment of adult closed comminuted radial head fractures (modified Mason type III and IV). Int Orthop 39(8):1659–1664CrossRefPubMed
6.
go back to reference Beingessner DM, Dunning CE, Gordon KD, Johnson JA, King GJ (2004) The effect of radial head excision and arthroplasty on elbow kinematics and stability. J Bone Joint Surg Am 86(8):1730–1739CrossRefPubMed Beingessner DM, Dunning CE, Gordon KD, Johnson JA, King GJ (2004) The effect of radial head excision and arthroplasty on elbow kinematics and stability. J Bone Joint Surg Am 86(8):1730–1739CrossRefPubMed
8.
go back to reference Duckworth AD, Clement ND, Jenkins PJ, Aitken SA, Court-Brown CM, McQueen MM (2012) The epidemiology of radial head and neck fractures. J Hand Surg 37(1):112–119CrossRef Duckworth AD, Clement ND, Jenkins PJ, Aitken SA, Court-Brown CM, McQueen MM (2012) The epidemiology of radial head and neck fractures. J Hand Surg 37(1):112–119CrossRef
10.
go back to reference Morrey BF, Sanchez-Sotelo J (2009) The elbow and its disorders. Elsevier Health Sciences, Amsterdam Morrey BF, Sanchez-Sotelo J (2009) The elbow and its disorders. Elsevier Health Sciences, Amsterdam
13.
go back to reference Li N, Chen S (2014) Open reduction and internal-fixation versus radial head replacement in treatment of Mason type III radial head fractures. Eur J Orthop Surg Traumatol 24(6):851–855CrossRefPubMed Li N, Chen S (2014) Open reduction and internal-fixation versus radial head replacement in treatment of Mason type III radial head fractures. Eur J Orthop Surg Traumatol 24(6):851–855CrossRefPubMed
15.
go back to reference Fowler JR, Henry SE, Xu P, Goitz RJ (2016) Outcomes following radial head arthroplasty. Orthopedics 39(3):153–160CrossRefPubMed Fowler JR, Henry SE, Xu P, Goitz RJ (2016) Outcomes following radial head arthroplasty. Orthopedics 39(3):153–160CrossRefPubMed
16.
go back to reference Marsh JP, Grewal R, Faber KJ, Drosdowech DS, Athwal GS, King GJ (2016) Radial head fractures treated with modular metallic radial head replacement: outcomes at a mean follow-up of eight years. JBJS 98(7):527–535CrossRef Marsh JP, Grewal R, Faber KJ, Drosdowech DS, Athwal GS, King GJ (2016) Radial head fractures treated with modular metallic radial head replacement: outcomes at a mean follow-up of eight years. JBJS 98(7):527–535CrossRef
17.
go back to reference Yalcinkaya M, Bagatur AE, Erdogan S, Zorer G (2013) Resection arthroplasty for Mason type III radial head fractures yield good clinical but poor radiological results in the long term. Orthopedics 36(11):e1358–e1364CrossRefPubMed Yalcinkaya M, Bagatur AE, Erdogan S, Zorer G (2013) Resection arthroplasty for Mason type III radial head fractures yield good clinical but poor radiological results in the long term. Orthopedics 36(11):e1358–e1364CrossRefPubMed
18.
go back to reference Schnetzke M, Aytac S, Deuss M, Studier-Fischer S, Swartman B, Muenzberg M, Gruetzner P-A, Guehring T (2014) Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIF. Int Orthop 38(11):2295–2301CrossRefPubMed Schnetzke M, Aytac S, Deuss M, Studier-Fischer S, Swartman B, Muenzberg M, Gruetzner P-A, Guehring T (2014) Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIF. Int Orthop 38(11):2295–2301CrossRefPubMed
20.
go back to reference Doornberg JN, Parisien R, van Duijn PJ, Ring D (2007) Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. JBJS 89(5):1075–1080CrossRef Doornberg JN, Parisien R, van Duijn PJ, Ring D (2007) Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. JBJS 89(5):1075–1080CrossRef
21.
go back to reference Popovic N, Lemaire R, Georis P, Gillet P (2007) Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am 89(11):2469–2476PubMed Popovic N, Lemaire R, Georis P, Gillet P (2007) Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am 89(11):2469–2476PubMed
22.
go back to reference Van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An K-N, O’Driscoll SW (2003) The noncircular shape of the radial head. J Hand Surg 28(6):972–978CrossRef Van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An K-N, O’Driscoll SW (2003) The noncircular shape of the radial head. J Hand Surg 28(6):972–978CrossRef
23.
go back to reference G C, F C, N M, E T, F B (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301CrossRef G C, F C, N M, E T, F B (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301CrossRef
24.
go back to reference Chen H, Wang Z, Shang Y (2017) Clinical and radiographic outcomes of unipolar and bipolar radial head prosthesis in patients with radial head fracture: a systemic review and meta-analysis. J Investig Surg 13:1–7 Chen H, Wang Z, Shang Y (2017) Clinical and radiographic outcomes of unipolar and bipolar radial head prosthesis in patients with radial head fracture: a systemic review and meta-analysis. J Investig Surg 13:1–7
25.
go back to reference Nestorson J, Josefsson PO, Adolfsson L (2017) A radial head prosthesis appears to be unnecessary in Mason-IV fracture dislocation. Acta Orthop 88(3):315–319CrossRefPubMedPubMedCentral Nestorson J, Josefsson PO, Adolfsson L (2017) A radial head prosthesis appears to be unnecessary in Mason-IV fracture dislocation. Acta Orthop 88(3):315–319CrossRefPubMedPubMedCentral
26.
go back to reference Van Hoecke E, Van De Vijver A, Van Glabbeek F, Gielen J (2016) Long term results after bipolar radial head arthroplasty. Acta Orthop Belg 82(2):382–388PubMed Van Hoecke E, Van De Vijver A, Van Glabbeek F, Gielen J (2016) Long term results after bipolar radial head arthroplasty. Acta Orthop Belg 82(2):382–388PubMed
27.
go back to reference Doornberg JN, Linzel DS, Zurakowski D, Ring D (2006) Reference points for radial head prosthesis size. J Hand Surg 31(1):53–57CrossRef Doornberg JN, Linzel DS, Zurakowski D, Ring D (2006) Reference points for radial head prosthesis size. J Hand Surg 31(1):53–57CrossRef
28.
go back to reference Doornberg JN, Van Duijn PJ, Linzel D, Ring DC, Zurakowski D, Marti RK, Kloen P (2007) Surgical treatment of intra-articular fractures of the distal part of the humerus. J Bone Joint Surg Am 89(7):1524–1532 Doornberg JN, Van Duijn PJ, Linzel D, Ring DC, Zurakowski D, Marti RK, Kloen P (2007) Surgical treatment of intra-articular fractures of the distal part of the humerus. J Bone Joint Surg Am 89(7):1524–1532
29.
go back to reference Neuhaus V, Christoforou DC, Kachooei AR, Jupiter JB, Ring DC, Mudgal CS (2015) Radial head prosthesis removal: a retrospective case series of 14 patients. Arch Bone Joint Surg 3(2):88PubMed Neuhaus V, Christoforou DC, Kachooei AR, Jupiter JB, Ring DC, Mudgal CS (2015) Radial head prosthesis removal: a retrospective case series of 14 patients. Arch Bone Joint Surg 3(2):88PubMed
30.
go back to reference Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ (2006) Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. J Bone Joint Surg 88(10):2192–2200PubMed Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ (2006) Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. J Bone Joint Surg 88(10):2192–2200PubMed
31.
go back to reference Morgan SJ, Groshen SL, Itamura JM, Shankwiler J, Brien WW, Kuschner SH (1997) Reliability evaluation of classifying radial head fractures by the system of Mason. Bull Hosp Jt Dis 56(2):95–98PubMed Morgan SJ, Groshen SL, Itamura JM, Shankwiler J, Brien WW, Kuschner SH (1997) Reliability evaluation of classifying radial head fractures by the system of Mason. Bull Hosp Jt Dis 56(2):95–98PubMed
32.
go back to reference Gruen TA, Mcneice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res (141):17–27 Gruen TA, Mcneice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res (141):17–27
35.
go back to reference Rotini R, Marinelli A, Guerra E, Bettelli G, Cavaciocchi M (2012) Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up. Musculoskelet Surg 96(1):69–79CrossRef Rotini R, Marinelli A, Guerra E, Bettelli G, Cavaciocchi M (2012) Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up. Musculoskelet Surg 96(1):69–79CrossRef
36.
go back to reference Van Riet R, Sanchez-Sotelo J, Morrey B (2010) Failure of metal radial head replacement. Bone Joint J 92(5):661–667 Van Riet R, Sanchez-Sotelo J, Morrey B (2010) Failure of metal radial head replacement. Bone Joint J 92(5):661–667
38.
go back to reference Chanlalit C, Shukla DR, Fitzsimmons JS, An K-N, O'Driscoll SW (2012) The biomechanical effect of prosthetic design on radiocapitellar stability in a terrible triad model. J Orthop Trauma 26(9):539–544CrossRefPubMed Chanlalit C, Shukla DR, Fitzsimmons JS, An K-N, O'Driscoll SW (2012) The biomechanical effect of prosthetic design on radiocapitellar stability in a terrible triad model. J Orthop Trauma 26(9):539–544CrossRefPubMed
39.
go back to reference Pomianowski S, Morrey BF, Neale PG, Park MJ, O'Driscoll SW, An KN (2001) Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow. J Bone Joint Surg Am 83(12):1829–1834CrossRefPubMed Pomianowski S, Morrey BF, Neale PG, Park MJ, O'Driscoll SW, An KN (2001) Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow. J Bone Joint Surg Am 83(12):1829–1834CrossRefPubMed
42.
go back to reference Laflamme M, Grenier-Gauthier PP, Leclerc A, Antoniades S, Bedard AM (2017) Retrospective cohort study on radial head replacements comparing results between smooth and porous stem designs. J Shoulder Elb Surg 26(8):1316–1324CrossRef Laflamme M, Grenier-Gauthier PP, Leclerc A, Antoniades S, Bedard AM (2017) Retrospective cohort study on radial head replacements comparing results between smooth and porous stem designs. J Shoulder Elb Surg 26(8):1316–1324CrossRef
43.
go back to reference Laumonerie P, Reina N, Gutierrez C, Delclaux S, Tibbo ME, Bonnevialle N, Mansat P (2018) Tight-fitting radial head prosthesis: does stem size help prevent painful loosening? Int Orthop 42(1):161–167CrossRefPubMed Laumonerie P, Reina N, Gutierrez C, Delclaux S, Tibbo ME, Bonnevialle N, Mansat P (2018) Tight-fitting radial head prosthesis: does stem size help prevent painful loosening? Int Orthop 42(1):161–167CrossRefPubMed
Metadata
Title
Complications after radial head arthroplasty: a comparison between short-stemmed bipolar and monopolar long-stemmed osteointegrative rigidly fixed prostheses
Authors
Yves Gramlich
Eva-Lorine Krausch
Alexander Klug
Johannes Buckup
Kay Schmidt-Horlohé
Reinhard Hoffmann
Publication date
01-08-2019
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 8/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-4173-7

Other articles of this Issue 8/2019

International Orthopaedics 8/2019 Go to the issue