Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up

Authors: Roberto Rotini, Alessandro Marinelli, Enrico Guerra, Graziano Bettelli, Michele Cavaciocchi

Published in: MUSCULOSKELETAL SURGERY | Special Issue 1/2012

Login to get access

Abstract

Radial head prosthetic replacement is indicated in case of comminuted fracture not amenable to internal fixation, especially when the radial head fracture is part of a pattern of lesions configuring a complex instability of the elbow. Thirty-one SBi radial head prostheses were implanted in 30 patients (one bilateral simultaneous fracture) over a 2 years period. In 10 patients, the mean time from trauma to surgical treatment was 2.4 days, while the remaining 20 patients were treated as “second opinion” cases presenting with elbow stiffness or instability after an average of 19 days from trauma. The implants were monopolar in 12 cases and bipolar in 19. The clinical results were evaluated through the Mayo Elbow performance scoring system. At an average follow-up of 2 years (range 13–36 months), the mean MEPS was 90 points (range 65–100). At late radiographic analysis, radiolucent lines around the stem were found in 11 of the 31 cases. Heterotopic ossifications were found in 14 cases. Bone resorption was observed in 9 cases. Two of the 31 prostheses were removed after 16 and 20 months, in one case to correct stiffness in pronation/supination, in the other one for asymptomatic aseptic mobilization. These short-term results are satisfactory, especially when considering that they were obtained in complex elbow lesions treated in many cases at a delayed stage. Our preference over time went more and more to bipolar implants, but from a comparison of the results we could find no evidence of a superiority of bipolar or monopolar implants. The evolution of these prostheses needs to be evaluated with further studies to assess mid-term and long-term follow-up results.
Literature
1.
go back to reference Morrey BF (2000) Radial head fracture. In: Morrey BF (ed) The elbow and its disorders, 3rd edn. WB Saunders, Philadelphia, pp 341–364 Morrey BF (2000) Radial head fracture. In: Morrey BF (ed) The elbow and its disorders, 3rd edn. WB Saunders, Philadelphia, pp 341–364
2.
go back to reference Morrey BF, O’Driscoll SW (2009) Complex Instability of the Elbow. In: Morrey BF (ed) The elbow and its disorders, 4th edn. Saunders Elsevier, Philadelphia, pp 450–462CrossRef Morrey BF, O’Driscoll SW (2009) Complex Instability of the Elbow. In: Morrey BF (ed) The elbow and its disorders, 4th edn. Saunders Elsevier, Philadelphia, pp 450–462CrossRef
3.
go back to reference O’Driscoll SW (2009) Elbow dislocations. In: Morrey BF (ed) The elbow and its disorders. 4th edn. Saunders Elsevier, Philadelphia, pp 436–449CrossRef O’Driscoll SW (2009) Elbow dislocations. In: Morrey BF (ed) The elbow and its disorders. 4th edn. Saunders Elsevier, Philadelphia, pp 436–449CrossRef
4.
go back to reference Beingessner DM, Dunning CE, Stacpoole RA, Johnson JA, King GJ (2007) The effect of coronoid fractures on elbow kinematics and stability. Clin Biomech (Bristol, Avon) 22(2):183–190. (Epub 2006 Nov 13) Beingessner DM, Dunning CE, Stacpoole RA, Johnson JA, King GJ (2007) The effect of coronoid fractures on elbow kinematics and stability. Clin Biomech (Bristol, Avon) 22(2):183–190. (Epub 2006 Nov 13)
5.
go back to reference Dunning CE, Zarzour ZD, Patterson SD, Johnson JA, King GJ (2001) Ligamentous stabilizers against posterolateral rotatory instability of the elbow. J Bone Joint Surg Am 83(A12):1823–1828PubMed Dunning CE, Zarzour ZD, Patterson SD, Johnson JA, King GJ (2001) Ligamentous stabilizers against posterolateral rotatory instability of the elbow. J Bone Joint Surg Am 83(A12):1823–1828PubMed
6.
go back to reference Zunkiewicz MR, Clemente JS, Miller MC, Baratz ME, Wysocki RW, Cohen MS (2012) Radial head replacement with a bipolar system: a minimum 2-year follow-up. J Shoulder Elbow Surg 21(1):98–104PubMedCrossRef Zunkiewicz MR, Clemente JS, Miller MC, Baratz ME, Wysocki RW, Cohen MS (2012) Radial head replacement with a bipolar system: a minimum 2-year follow-up. J Shoulder Elbow Surg 21(1):98–104PubMedCrossRef
7.
go back to reference Yian E, Steens W, Lingenfelter E, Schneeberger AG (2008) Malpositioning of radial head prostheses: an in vitro study. J Shoulder Elbow Surg 17(4):663–670PubMedCrossRef Yian E, Steens W, Lingenfelter E, Schneeberger AG (2008) Malpositioning of radial head prostheses: an in vitro study. J Shoulder Elbow Surg 17(4):663–670PubMedCrossRef
8.
go back to reference Van Riet RP, Morrey BF (2008) Documentation of associated injuries occurring with radial head fracture. Clin Orthop Relat Res 466(1):130–134PubMedCrossRef Van Riet RP, Morrey BF (2008) Documentation of associated injuries occurring with radial head fracture. Clin Orthop Relat Res 466(1):130–134PubMedCrossRef
9.
go back to reference Van Riet RP, Van Glabbeek F, Morrey BF (2009) Radial head fractures. In: Morrey BF, Sanchez-Sotelo J (eds) The elbow and its disorders, 4th edn. Saunders Elsevier, Philadelphia, pp 359–388 Van Riet RP, Van Glabbeek F, Morrey BF (2009) Radial head fractures. In: Morrey BF, Sanchez-Sotelo J (eds) The elbow and its disorders, 4th edn. Saunders Elsevier, Philadelphia, pp 359–388
10.
go back to reference Regan W, Morrey B (1989) Fractures of the coronoid process of the ulna. J Bone Joint Surg Am 71(9):1348–1354PubMed Regan W, Morrey B (1989) Fractures of the coronoid process of the ulna. J Bone Joint Surg Am 71(9):1348–1354PubMed
11.
go back to reference Morrey BF, An KN, Chao EYS (1993) Functional evaluation of the elbow. In: Morrey BF (ed) The elbow and its disorders, 2nd edn. Saunders, Philadelphia, WB, pp 36–59 Morrey BF, An KN, Chao EYS (1993) Functional evaluation of the elbow. In: Morrey BF (ed) The elbow and its disorders, 2nd edn. Saunders, Philadelphia, WB, pp 36–59
12.
go back to reference Broberg MA, Morrey BF (1986) Results of delayed excision of the radial head after fracture. J Bone Joint Surg Am 68(5):669–674PubMed Broberg MA, Morrey BF (1986) Results of delayed excision of the radial head after fracture. J Bone Joint Surg Am 68(5):669–674PubMed
13.
go back to reference Ilahi OA, Strausser DW, Gabel GT (1998) Post-traumatic heterotopic ossification about the elbow. Orthopedics 21(3):265–268PubMed Ilahi OA, Strausser DW, Gabel GT (1998) Post-traumatic heterotopic ossification about the elbow. Orthopedics 21(3):265–268PubMed
14.
go back to reference Ilahi OA, Bennett JB, Gabel GT, Mehlhoff TL, Kohl HW 3rd (2001) Classification of heterotopic ossification about the elbow. Orthopedics 24(11):1075–1077PubMed Ilahi OA, Bennett JB, Gabel GT, Mehlhoff TL, Kohl HW 3rd (2001) Classification of heterotopic ossification about the elbow. Orthopedics 24(11):1075–1077PubMed
15.
go back to reference Moon JG, Berglund LJ, Domire Z, An KN, O’Driscoll SW (2009) Stem diameter and micromotion of press fit radial head prosthesis: a biomechanical study. J Shoulder Elbow Surg 18(5):785–790PubMedCrossRef Moon JG, Berglund LJ, Domire Z, An KN, O’Driscoll SW (2009) Stem diameter and micromotion of press fit radial head prosthesis: a biomechanical study. J Shoulder Elbow Surg 18(5):785–790PubMedCrossRef
16.
go back to reference Rowland AS, Athwal GS, MacDermid JC, King GJ (2007) Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing. J Hand Surg Am 32(5):637–641PubMedCrossRef Rowland AS, Athwal GS, MacDermid JC, King GJ (2007) Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing. J Hand Surg Am 32(5):637–641PubMedCrossRef
17.
go back to reference Shors HC, Gannon C, Miller MC, Schmidt CC, Baratz ME (2008) Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis. J Hand Surg Am 33(3):335–339PubMedCrossRef Shors HC, Gannon C, Miller MC, Schmidt CC, Baratz ME (2008) Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis. J Hand Surg Am 33(3):335–339PubMedCrossRef
18.
go back to reference Morrey BF, Harter GD (2009) Ectopic ossification about the elbow. In: Morrey BF, Sanchez-Sotelo J (eds) The elbow and its disorders, 4th edn. Saunders Elsevier, Philadelphia, pp 472–486CrossRef Morrey BF, Harter GD (2009) Ectopic ossification about the elbow. In: Morrey BF, Sanchez-Sotelo J (eds) The elbow and its disorders, 4th edn. Saunders Elsevier, Philadelphia, pp 472–486CrossRef
19.
go back to reference Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ (2006) Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes. J Bone Joint Surg Am 88(10):2192–2200PubMedCrossRef Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ (2006) Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes. J Bone Joint Surg Am 88(10):2192–2200PubMedCrossRef
20.
go back to reference Harrington IJ, Sekyi-Otu A, Barrington TW, Evans DC, Tuli V (2001) The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review. J Trauma 50(1):46–52PubMedCrossRef Harrington IJ, Sekyi-Otu A, Barrington TW, Evans DC, Tuli V (2001) The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review. J Trauma 50(1):46–52PubMedCrossRef
21.
go back to reference Shore BJ, Mozzon JB, MacDermid JC, Faber KJ, King GJ (2008) Chronic posttraumatic elbow disorders treated with metallic radial head arthroplasty. J Bone Joint Surg Am 90(2):271–280PubMedCrossRef Shore BJ, Mozzon JB, MacDermid JC, Faber KJ, King GJ (2008) Chronic posttraumatic elbow disorders treated with metallic radial head arthroplasty. J Bone Joint Surg Am 90(2):271–280PubMedCrossRef
22.
go back to reference Popovic N, Lemaire R, Georis P, Gillet P (2007) Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am 89(11):2469–2476PubMedCrossRef Popovic N, Lemaire R, Georis P, Gillet P (2007) Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am 89(11):2469–2476PubMedCrossRef
23.
go back to reference Burkhart KJ, MattyasovszkSy SG, Runkel M, Schwarz C, Küchle R, Hessmann MH, Rommens PM, Lars MP (2010) Mid- to long-term results after bipolar radial head arthroplasty. J Shoulder Elbow Surg 19(7):965–972PubMedCrossRef Burkhart KJ, MattyasovszkSy SG, Runkel M, Schwarz C, Küchle R, Hessmann MH, Rommens PM, Lars MP (2010) Mid- to long-term results after bipolar radial head arthroplasty. J Shoulder Elbow Surg 19(7):965–972PubMedCrossRef
24.
go back to reference Celli A, Modena F, Celli L (2010) The acute bipolar radial head replacement for isolated unreconstructable fractures of the radial head. Musculoskelet Surg 94(Suppl 1):S3–S9PubMedCrossRef Celli A, Modena F, Celli L (2010) The acute bipolar radial head replacement for isolated unreconstructable fractures of the radial head. Musculoskelet Surg 94(Suppl 1):S3–S9PubMedCrossRef
25.
go back to reference O’Driscoll SW, Herald JA (2012) Forearm pain associated with loose radial head prostheses. J Shoulder Elbow Surg 21(1):92–97PubMedCrossRef O’Driscoll SW, Herald JA (2012) Forearm pain associated with loose radial head prostheses. J Shoulder Elbow Surg 21(1):92–97PubMedCrossRef
26.
go back to reference Shukla DR, Fitzsimmons JS, An KN, O’Driscoll SW (2012) Effect of stem length on prosthetic radial head micromotion. J Shoulder Elbow Surg (Epub ahead of print) Shukla DR, Fitzsimmons JS, An KN, O’Driscoll SW (2012) Effect of stem length on prosthetic radial head micromotion. J Shoulder Elbow Surg (Epub ahead of print)
Metadata
Title
Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up
Authors
Roberto Rotini
Alessandro Marinelli
Enrico Guerra
Graziano Bettelli
Michele Cavaciocchi
Publication date
01-05-2012
Publisher
Springer Milan
Published in
MUSCULOSKELETAL SURGERY / Issue Special Issue 1/2012
Print ISSN: 2035-5106
Electronic ISSN: 2035-5114
DOI
https://doi.org/10.1007/s12306-012-0198-z

Other articles of this Special Issue 1/2012

MUSCULOSKELETAL SURGERY 1/2012 Go to the issue

Editorial

Editorial