Published in: International Orthopaedics 5/2018

01-05-2018 | Original Paper

Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register

Authors: Justinas Stucinskas, Tomas Kalvaitis, Alfredas Smailys, Otto Robertsson, Sarunas Tarasevicius

Published in: International Orthopaedics | Issue 5/2018

Login to get access

Abstract

Purpose

Recently, there has been increasing interest in the use of dual mobility systems in the treatment of hip instability. The aim of this study was to investigate the re-revision rate of dual mobility cup compared to different surgical concepts when used for first-time hip revisions due to recurrent dislocations.

Methods

The data were derived from the Lithuanian Arthroplasty Register. For survival analysis, we used both re-revision for all reasons and for dislocations as an end-point. Cox proportional hazards models were used to analyze the influence of various covariates (age, gender, and implant concept).

Results

A total of 1388 revisions were recorded from 2011 to 2015, of which 362 were performed due to recurrent dislocation. Of the revisions, 247 were performed using dual mobility cups, while 115 were performed using a variety of other surgical constructs including constrained acetabular cups, conventional cups, femoral head exchanges, stem exchanges or anti-luxation rings. There were 27 re-revisions of which 15 were for additional dislocations. There were only 2% re-revisions due to dislocation with dual mobility vs 9% when using other surgical constructs. Cox regression adjusting for age and gender showed that in the short-term, dual mobility cup had a lower risk of revision due to dislocation as well as for all reasons compared to the other surgical constructs.

Conclusion

In revision of total hip arthroplasties for dislocation, significantly lower short-term re-revision rate was observed for patients revised with dual mobility cup.
Literature
1.
go back to reference Parvizi J, Picinic E, Sharkey PF (2008) Revision total hip arthroplasty for instability: surgical techniques and principles. J Bone Joint Surg Am 90(5):1134–1142PubMed Parvizi J, Picinic E, Sharkey PF (2008) Revision total hip arthroplasty for instability: surgical techniques and principles. J Bone Joint Surg Am 90(5):1134–1142PubMed
2.
go back to reference Enocson A, Hedbeck CJ, Tidermark J, Pettersson H, Ponzer S, Lapidus LJ (2009) Dislocation of total hip replacement in patients with fractures of the femoral neck. Acta Orthop 80:184–189CrossRefPubMedPubMedCentral Enocson A, Hedbeck CJ, Tidermark J, Pettersson H, Ponzer S, Lapidus LJ (2009) Dislocation of total hip replacement in patients with fractures of the femoral neck. Acta Orthop 80:184–189CrossRefPubMedPubMedCentral
3.
go back to reference Zagra L, Caboni E (2017) Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options. Int Orthop 41(3):661–668CrossRefPubMed Zagra L, Caboni E (2017) Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options. Int Orthop 41(3):661–668CrossRefPubMed
4.
go back to reference Bousquet G, Argenson C, Godeneche JL, Cisterne JP, Gazielly DF, Girardin P, Debiesse JL (1986) Recovery after aseptic loosening of cemented total hip arthroplasties with Bousquet’s cementless prosthesis. Apropos of 136 cases. Rev Chir Orthop Reparatrice Appar Mot 72(2):70–74PubMed Bousquet G, Argenson C, Godeneche JL, Cisterne JP, Gazielly DF, Girardin P, Debiesse JL (1986) Recovery after aseptic loosening of cemented total hip arthroplasties with Bousquet’s cementless prosthesis. Apropos of 136 cases. Rev Chir Orthop Reparatrice Appar Mot 72(2):70–74PubMed
6.
go back to reference Philippot R, Adam P, Reckhaus M, Delangle F, Verdot F, Curvale G, Farizon F (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95:407CrossRefPubMed Philippot R, Adam P, Reckhaus M, Delangle F, Verdot F, Curvale G, Farizon F (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95:407CrossRefPubMed
7.
go back to reference Guyen O, Pibarot V, Vaz G, Chevillotte C, Béjui-Hugues J (2009) Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res 467:465CrossRefPubMed Guyen O, Pibarot V, Vaz G, Chevillotte C, Béjui-Hugues J (2009) Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res 467:465CrossRefPubMed
8.
go back to reference Massin P, Besnier L (2010) Acetabular revision of total hip arthroplasty using a press-fit dual mobility cup. Orthop Traumatol Surg Res 96:9CrossRefPubMed Massin P, Besnier L (2010) Acetabular revision of total hip arthroplasty using a press-fit dual mobility cup. Orthop Traumatol Surg Res 96:9CrossRefPubMed
9.
go back to reference Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M (2012) A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 470:3542CrossRefPubMedPubMedCentral Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M (2012) A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 470:3542CrossRefPubMedPubMedCentral
10.
go back to reference Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) Dual-mobility cups for revision to instability are associated with a low rate of re-revisions due to dislocation. 228 patients from the Swedish hip Arthroplasty register. Acta Orthop 83:566CrossRefPubMedPubMedCentral Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) Dual-mobility cups for revision to instability are associated with a low rate of re-revisions due to dislocation. 228 patients from the Swedish hip Arthroplasty register. Acta Orthop 83:566CrossRefPubMedPubMedCentral
11.
go back to reference Vasukutty NL, Middleton RG, Matthews EC, Young PS, Uzoigwe CE, Minhas TH (2012) The double-mobility acetabular component in revision total hip replacement. The United Kingdom experience. J Bone Joint Surg Br 94:603–608 Vasukutty NL, Middleton RG, Matthews EC, Young PS, Uzoigwe CE, Minhas TH (2012) The double-mobility acetabular component in revision total hip replacement. The United Kingdom experience. J Bone Joint Surg Br 94:603–608
12.
go back to reference Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Béjui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision Total hip Arthroplasty? J Arthroplast 30(4):631–640CrossRef Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Béjui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision Total hip Arthroplasty? J Arthroplast 30(4):631–640CrossRef
13.
14.
go back to reference Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38(12):2463–2468CrossRefPubMed Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38(12):2463–2468CrossRefPubMed
15.
go back to reference Hamadouche M, Ropars M, Rodaix C, Musset T, Gaucher F, Biau D, Courpied JP, Huten D (2017) Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation. Int Orthop 41(3):513–519CrossRefPubMed Hamadouche M, Ropars M, Rodaix C, Musset T, Gaucher F, Biau D, Courpied JP, Huten D (2017) Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation. Int Orthop 41(3):513–519CrossRefPubMed
16.
go back to reference Viste A, Desmarchelier R, Fessy MH (2017) Dual mobility cups in revision total hip arthroplasty. Int Orthop 41(3):535–542CrossRefPubMed Viste A, Desmarchelier R, Fessy MH (2017) Dual mobility cups in revision total hip arthroplasty. Int Orthop 41(3):535–542CrossRefPubMed
17.
go back to reference Mohaddes M, Cnudde P, Rolfson O, Wall A, Kärrholm J (2017) Use of dual-mobility cup in revision hip arthroplasty reduces the risk for further dislocation: analysis of seven hundred and ninety one first-time revisions performed due to dislocation, reported to the Swedish hip Arthroplasty register. Int Orthop 41(3):583–588CrossRefPubMed Mohaddes M, Cnudde P, Rolfson O, Wall A, Kärrholm J (2017) Use of dual-mobility cup in revision hip arthroplasty reduces the risk for further dislocation: analysis of seven hundred and ninety one first-time revisions performed due to dislocation, reported to the Swedish hip Arthroplasty register. Int Orthop 41(3):583–588CrossRefPubMed
18.
go back to reference Sadoghi P, Leithner A, Labek G (2013) Overcoming boundaries of worldwide joint arthroplasty registers: the European Arthroplasty register minimal dataset. J Arthroplast 28(8):1327–1328CrossRef Sadoghi P, Leithner A, Labek G (2013) Overcoming boundaries of worldwide joint arthroplasty registers: the European Arthroplasty register minimal dataset. J Arthroplast 28(8):1327–1328CrossRef
19.
go back to reference Tarasevičius S, Čebatorius A, Valavičienė R, Stučinskas J, Leonas L, Robertsson O (2014) First outcome results after total knee and hip replacement from the Lithuanian arthroplasty register. Medicina (Kaunas) 50(2):87–91CrossRef Tarasevičius S, Čebatorius A, Valavičienė R, Stučinskas J, Leonas L, Robertsson O (2014) First outcome results after total knee and hip replacement from the Lithuanian arthroplasty register. Medicina (Kaunas) 50(2):87–91CrossRef
20.
go back to reference Dorey F, Nasser S, Amstutz H (1993) The need for confidence intervals in the presentation of orthopaedic data. J Bone Joint Surg Am 75(12):1844–1852CrossRefPubMed Dorey F, Nasser S, Amstutz H (1993) The need for confidence intervals in the presentation of orthopaedic data. J Bone Joint Surg Am 75(12):1844–1852CrossRefPubMed
21.
go back to reference StataCorp (2013) Stata statistical software: release 13. StataCorp LP, College Station StataCorp (2013) Stata statistical software: release 13. StataCorp LP, College Station
22.
go back to reference Saragaglia D, Ruatti S, Refaie R (2013) Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series. Eur J Orthop Surg Traumatol 23(4):431–436CrossRefPubMed Saragaglia D, Ruatti S, Refaie R (2013) Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series. Eur J Orthop Surg Traumatol 23(4):431–436CrossRefPubMed
23.
go back to reference Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97(1):8–13CrossRefPubMed Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97(1):8–13CrossRefPubMed
24.
go back to reference Stedman RC, Lim D, Husain A, Courtney PM, Nelson CL (2016) Single-component revisions are associated with dislocation after revision total hip arthroplasty at intermediate-term follow-up. Hip Int 26(3):233–236CrossRefPubMed Stedman RC, Lim D, Husain A, Courtney PM, Nelson CL (2016) Single-component revisions are associated with dislocation after revision total hip arthroplasty at intermediate-term follow-up. Hip Int 26(3):233–236CrossRefPubMed
25.
go back to reference Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH, Groseth KL (2005) The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty (Suppl 3) 20(7):93–102CrossRef Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH, Groseth KL (2005) The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty (Suppl 3) 20(7):93–102CrossRef
26.
go back to reference Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty (Suppl 3) 20(7):103–107CrossRef Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty (Suppl 3) 20(7):103–107CrossRef
27.
go back to reference Yun AG, Padgett D, Pellicci P, Dorr LD (2005) Constrained acetabular liners: mechanisms of failure. J Arthroplast 20(4):536–541CrossRef Yun AG, Padgett D, Pellicci P, Dorr LD (2005) Constrained acetabular liners: mechanisms of failure. J Arthroplast 20(4):536–541CrossRef
28.
go back to reference Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip following total hip arthroplasty: a literature review. Int Orthop 31(3):273–277CrossRefPubMed Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip following total hip arthroplasty: a literature review. Int Orthop 31(3):273–277CrossRefPubMed
29.
go back to reference Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop 36(3):511–518CrossRefPubMed Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop 36(3):511–518CrossRefPubMed
30.
go back to reference Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty register. Acta Orthop 83(5):442–448CrossRefPubMedPubMedCentral Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty register. Acta Orthop 83(5):442–448CrossRefPubMedPubMedCentral
31.
Metadata
Title
Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register
Authors
Justinas Stucinskas
Tomas Kalvaitis
Alfredas Smailys
Otto Robertsson
Sarunas Tarasevicius
Publication date
01-05-2018
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 5/2018
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3702-0

Other articles of this Issue 5/2018

International Orthopaedics 5/2018 Go to the issue