Purpose

To investigate the treatment of acetabular anterior column fractures using a two-incision minimally invasive (TIMI) approach and minimally invasive plate osteosynthesis (MIPO) technique using a preshaped 3D plate.

Methods

A group of 12 consecutive cases of acetabular fractures from March 2013 to July 2014 were treated with the TIMI approach. 3D mirror models of the uninjured side of the hemipelvis were printed preoperatively; the plates used in surgery were preshaped according to these models. MIPO surgical techniques were applied. All patients had a minimum one year radiographic and clinical follow-up.

Results

Seven fractures involved the anterior column, four were anterior column with posterior hemitransverse, and one was anterior column with the pubic symphysis. The average surgery time was 200 minutes, and mean blood loss was 1004 ml. The fracture reduction results as assessed by Matta radiographic outcome scores were good in eight, satisfactory in three, and poor in one patient. Functional outcomes according to the Harris hip scores were excellent for seven, good for three, and fair for two. Post-operative complications included incomplete femoral nerve damage and abdominal cavity injury.

Conclusions

The TIMI approach is an alternative to the ilioinguinal approach for anterior column acetabular fracture treatment, especially for fractures involving the dome and quadrilateral plate that are feasible for application of MIPO techniques. The technique of preshaping the 3D plate makes the plate better accommodated to the fracture surface and easier to apply in MIPO procedures. All dissection was between the anatomical interval, which allowed less soft tissue injury and related complications, and caused less bleeding. The fracture types in our case series were relatively simple, and follow-up time was short; more clinical trials are necessary for evaluation of middle- and late-term results.
Literature
1.
go back to reference Letournel E (1961) Les fractures du cotyle. Etude d’une se’rie de 75 cas. J Chir 82:47–87 Letournel E (1961) Les fractures du cotyle. Etude d’une se’rie de 75 cas. J Chir 82:47–87
2.
go back to reference Letournel E (1993) The treatment of acetabular fractures through the ilioinguinal approach. Clin Orthop 292:62–76PubMed Letournel E (1993) The treatment of acetabular fractures through the ilioinguinal approach. Clin Orthop 292:62–76PubMed
3.
go back to reference Cole JD, Bolhofner BR (1994) Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach. Description of operative technique and preliminary treatment results. Clin Orthop Relat Res 305:112–123CrossRefPubMed Cole JD, Bolhofner BR (1994) Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach. Description of operative technique and preliminary treatment results. Clin Orthop Relat Res 305:112–123CrossRefPubMed
4.
go back to reference Keel MJB, Ecker TM, Cullmann JL, Bergmann M, Bonel HM, Büchler L, Siebenrock KA, Bastian JD (2012) The pararectus approach for anterior intrapelvic management of acetabular fractures. J Bone Joint Surg (Br) 94:405–411CrossRef Keel MJB, Ecker TM, Cullmann JL, Bergmann M, Bonel HM, Büchler L, Siebenrock KA, Bastian JD (2012) The pararectus approach for anterior intrapelvic management of acetabular fractures. J Bone Joint Surg (Br) 94:405–411CrossRef
5.
go back to reference Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury 36:530–538CrossRefPubMed Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury 36:530–538CrossRefPubMed
6.
go back to reference Apivatthakakul T, Chiewcharntanakit S (2008) Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop 33(4):1119–1126CrossRefPubMedPubMedCentral Apivatthakakul T, Chiewcharntanakit S (2008) Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop 33(4):1119–1126CrossRefPubMedPubMedCentral
7.
go back to reference Cole PA, Gauger EM, Anavian J, Ly TV, Morgan RA, Heddings AA (2012) Anterior pelvic external fixator versus subcutaneous internal fixator in the treatment of anterior ring pelvic fractures. J Orthop Trauma 26(5):269–277CrossRefPubMed Cole PA, Gauger EM, Anavian J, Ly TV, Morgan RA, Heddings AA (2012) Anterior pelvic external fixator versus subcutaneous internal fixator in the treatment of anterior ring pelvic fractures. J Orthop Trauma 26(5):269–277CrossRefPubMed
8.
go back to reference Abo-Elsoud M, Radwan YA, Gobba M, Sadek F (2014) Short-segment fixation through a limited ilioinguinal approach for treating anterior acetabular fractures: a historical-control study. Int Orthop 38(7):1469–1475CrossRefPubMedPubMedCentral Abo-Elsoud M, Radwan YA, Gobba M, Sadek F (2014) Short-segment fixation through a limited ilioinguinal approach for treating anterior acetabular fractures: a historical-control study. Int Orthop 38(7):1469–1475CrossRefPubMedPubMedCentral
9.
go back to reference Ruchholtz S, Buecking B, Delschen A, Lewan U, Taeger G, Kuehne C, Zettl R (2013) The two-incision, minimally invasive approach in the treatment of acetabular fractures. J Orthop Trauma 27(5):248–255CrossRefPubMed Ruchholtz S, Buecking B, Delschen A, Lewan U, Taeger G, Kuehne C, Zettl R (2013) The two-incision, minimally invasive approach in the treatment of acetabular fractures. J Orthop Trauma 27(5):248–255CrossRefPubMed
10.
go back to reference Kim JW, Herbert B, Hao J, Min W, Ziran BH, Mauffrey C (2015) Acetabular fractures in elderly patients: a comparative study of low-energy versus high-energy injuries. Int Orthop 39(6):1175–1179CrossRefPubMed Kim JW, Herbert B, Hao J, Min W, Ziran BH, Mauffrey C (2015) Acetabular fractures in elderly patients: a comparative study of low-energy versus high-energy injuries. Int Orthop 39(6):1175–1179CrossRefPubMed
11.
go back to reference Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80:814–820CrossRefPubMed Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80:814–820CrossRefPubMed
12.
go back to reference Brown GA, Firoozbakhsh K, DeCoster TA, ReynaJr JR, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85:49–55PubMed Brown GA, Firoozbakhsh K, DeCoster TA, ReynaJr JR, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85:49–55PubMed
13.
go back to reference Hurson C, Tansey A, O’donnchadha B et al (2007) Rapid prototyping in the assessment, classification and preoperative planning of acetabular fracture. Injury 38(10):1158–1162CrossRefPubMed Hurson C, Tansey A, O’donnchadha B et al (2007) Rapid prototyping in the assessment, classification and preoperative planning of acetabular fracture. Injury 38(10):1158–1162CrossRefPubMed
Metadata
Title
Minimally invasive plate osteosynthesis of acetabular anterior column fractures using the two-incision minimally invasive approach and a preshaped three dimension plate
Authors
Yan Zhuang
Shenglu Cao
Yanbin Lin
Renbin Li
Gang Wang
Yiran Wang
Publication date
01-10-2016
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 10/2016
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-3111-1

Other articles of this Issue 10/2016

International Orthopaedics 10/2016 Go to the issue