Skip to main content
Top
Published in: International Orthopaedics 8/2016

01-08-2016 | Original Paper

Biomechanical evaluation of different surgical techniques for treating patellar tendon ruptures

Authors: Benedikt Schliemann, Niklas Grüneweller, Daiwei Yao, Clemens Kösters, Simon Lenschow, Steffen B. Roßlenbroich, Michael J. Raschke, Andre Weimann

Published in: International Orthopaedics | Issue 8/2016

Login to get access

Abstract

Purpose

The aim of this study was to biomechanically assess patellar tendon repair techniques with additional cable wire or polydioxanone suture (PDS) cord augmentation in comparison with a suture-anchor repair technique.

Methods

Patellar tendon repair was performed in 60 specimens using a porcine bone model. Yield load, maximum load, stiffness and elongation of patellar tendon reconstructions with (1) cable wire augmentation, (2) PDS cord augmentation or (3) suture anchor repair were evaluated using a cyclic loading and load-to-failure test setup.

Results

In comparison with suture anchor repair, augmentation of the reconstruction with either cable wires or PDS cords provides significantly higher maximum loads (527 and 460 N vs. 301 N; p < 0.01 and p = 0,012, respectively) under load-to-failure testing and less elongation (8.81 mm ± 1.55 mm and 10.56 mm ± 3.1 mm vs. 18.38 mm ± 7.51 mm; p = 0.037 and p = 0.033, respectively) under cyclic loading conditions.

Conclusion

Augmentation of a patellar tendon repair with either a cable wire or a PDS cord provides higher primary stability than suture anchor repair in patellar tendon ruptures. The study supports the use of additional augmentation of a tendon repair in the clinical setting in order to prevent loss of reduction and allow for early post-operative mobilisation.
Literature
3.
go back to reference Bushnell BD, Tennant JN, Rubright JH, Creighton RA (2008) Repair of patellar tendon rupture using suture anchors. J Knee Surg 21(2):122–129PubMed Bushnell BD, Tennant JN, Rubright JH, Creighton RA (2008) Repair of patellar tendon rupture using suture anchors. J Knee Surg 21(2):122–129PubMed
5.
6.
go back to reference Doral MN (2013) What is the effect of the early weight-bearing mobilisation without using any support after endoscopy-assisted Achilles tendon repair? Knee Surg Sports Traumatol Arthrosc 21(6):1378–1384. doi:10.1007/s00167-012-2222-0 CrossRefPubMed Doral MN (2013) What is the effect of the early weight-bearing mobilisation without using any support after endoscopy-assisted Achilles tendon repair? Knee Surg Sports Traumatol Arthrosc 21(6):1378–1384. doi:10.​1007/​s00167-012-2222-0 CrossRefPubMed
7.
go back to reference Ettinger M, Dratzidis A, Hurschler C, Brand S, Calliess T, Krettek C, Jagodzinski M, Petri M (2013) Biomechanical properties of suture anchor repair compared with transosseous sutures in patellar tendon ruptures: a cadaveric study. Am J Sports Med 41(11):2540–2544. doi:10.1177/0363546513500633 CrossRefPubMed Ettinger M, Dratzidis A, Hurschler C, Brand S, Calliess T, Krettek C, Jagodzinski M, Petri M (2013) Biomechanical properties of suture anchor repair compared with transosseous sutures in patellar tendon ruptures: a cadaveric study. Am J Sports Med 41(11):2540–2544. doi:10.​1177/​0363546513500633​ CrossRefPubMed
11.
go back to reference Kadar A, Sherman H, Drexler M, Katz E, Steinberg EL (2015) Anchor suture fixation of distal pole fractures of patella: twenty seven cases and comparison to partial patellectomy. Int Orthop. doi:10.1007/s00264-015-2776-9 PubMed Kadar A, Sherman H, Drexler M, Katz E, Steinberg EL (2015) Anchor suture fixation of distal pole fractures of patella: twenty seven cases and comparison to partial patellectomy. Int Orthop. doi:10.​1007/​s00264-015-2776-9 PubMed
12.
go back to reference Kasten P, Schewe B, Maurer F, Gosling T, Krettek C, Weise K (2001) Rupture of the patellar tendon: a review of 68 cases and a retrospective study of 29 ruptures comparing two methods of augmentation. Arch Orthop Trauma Surg 121(10):578–582CrossRefPubMed Kasten P, Schewe B, Maurer F, Gosling T, Krettek C, Weise K (2001) Rupture of the patellar tendon: a review of 68 cases and a retrospective study of 29 ruptures comparing two methods of augmentation. Arch Orthop Trauma Surg 121(10):578–582CrossRefPubMed
13.
go back to reference Krackow KA, Thomas SC, Jones LC (1986) A new stitch for ligament-tendon fixation. Brief note. J Bone Joint Surg Am 68(5):764–766PubMed Krackow KA, Thomas SC, Jones LC (1986) A new stitch for ligament-tendon fixation. Brief note. J Bone Joint Surg Am 68(5):764–766PubMed
14.
go back to reference Langenhan R, Baumann M, Ricart P, Hak D, Probst A, Badke A, Trobisch P (2012) Postoperative functional rehabilitation after repair of quadriceps tendon ruptures: a comparison of two different protocols. Knee Surg Sports Traumatol Arthrosc 20(11):2275–2278. doi:10.1007/s00167-012-1887-8 CrossRefPubMed Langenhan R, Baumann M, Ricart P, Hak D, Probst A, Badke A, Trobisch P (2012) Postoperative functional rehabilitation after repair of quadriceps tendon ruptures: a comparison of two different protocols. Knee Surg Sports Traumatol Arthrosc 20(11):2275–2278. doi:10.​1007/​s00167-012-1887-8 CrossRefPubMed
15.
go back to reference Lenschow S, Herbort M, Strasser A, Strobel M, Raschke M, Petersen W, Zantop T (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg 131(8):1067–1072. doi:10.1007/s00402-011-1276-7 CrossRefPubMed Lenschow S, Herbort M, Strasser A, Strobel M, Raschke M, Petersen W, Zantop T (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg 131(8):1067–1072. doi:10.​1007/​s00402-011-1276-7 CrossRefPubMed
16.
go back to reference Lenschow S, Schliemann B, Schulze M, Raschke M, Kosters C (2014) Comparison of outside-in and inside-out technique for tibial fixation of a soft-tissue graft in ACL reconstruction using the Shim technique. Arch Orthop Trauma Surg 134(9):1293–1299. doi:10.1007/s00402-014-2029-1 CrossRefPubMed Lenschow S, Schliemann B, Schulze M, Raschke M, Kosters C (2014) Comparison of outside-in and inside-out technique for tibial fixation of a soft-tissue graft in ACL reconstruction using the Shim technique. Arch Orthop Trauma Surg 134(9):1293–1299. doi:10.​1007/​s00402-014-2029-1 CrossRefPubMed
17.
go back to reference Liu SH, Kabo JM, Osti L (1995) Biomechanics of two types of bone-tendon-bone graft for ACL reconstruction. J Bone Joint Surg (Br) 77(2):232–235 Liu SH, Kabo JM, Osti L (1995) Biomechanics of two types of bone-tendon-bone graft for ACL reconstruction. J Bone Joint Surg (Br) 77(2):232–235
18.
go back to reference Marder RA, Timmerman LA (1999) Primary repair of patellar tendon rupture without augmentation. Am J Sports Med 27(3):304–307PubMed Marder RA, Timmerman LA (1999) Primary repair of patellar tendon rupture without augmentation. Am J Sports Med 27(3):304–307PubMed
19.
go back to reference Mc LH (1947) Repair of major tendon ruptures by buried removable suture. Am J Surg 74(5):758–764CrossRef Mc LH (1947) Repair of major tendon ruptures by buried removable suture. Am J Surg 74(5):758–764CrossRef
20.
go back to reference Mittlmeier T, Ewert A (2001) Injuries of the knee joint extensor system. Unfallchirurg 104(4):344–356, quiz 356 CrossRefPubMed Mittlmeier T, Ewert A (2001) Injuries of the knee joint extensor system. Unfallchirurg 104(4):344–356, quiz 356 CrossRefPubMed
21.
go back to reference Nurmi JT, Sievanen H, Kannus P, Jarvinen M, Jarvinen TL (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32(3):765–771CrossRefPubMed Nurmi JT, Sievanen H, Kannus P, Jarvinen M, Jarvinen TL (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32(3):765–771CrossRefPubMed
26.
go back to reference Ravalin RV, Mazzocca AD, Grady-Benson JC, Nissen CW, Adams DJ (2002) Biomechanical comparison of patellar tendon repairs in a cadaver model: an evaluation of gap formation at the repair site with cyclic loading. Am J Sports Med 30(4):469–473PubMed Ravalin RV, Mazzocca AD, Grady-Benson JC, Nissen CW, Adams DJ (2002) Biomechanical comparison of patellar tendon repairs in a cadaver model: an evaluation of gap formation at the repair site with cyclic loading. Am J Sports Med 30(4):469–473PubMed
Metadata
Title
Biomechanical evaluation of different surgical techniques for treating patellar tendon ruptures
Authors
Benedikt Schliemann
Niklas Grüneweller
Daiwei Yao
Clemens Kösters
Simon Lenschow
Steffen B. Roßlenbroich
Michael J. Raschke
Andre Weimann
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 8/2016
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-3003-4