Abstract

Purpose

Treatment of complex fractures of the distal femur utilizing monoaxial locking plates (e.g. Less Invasive Stabilisation System, LISS®, Synthes) is considered to be superior to conventional plating systems. Due to the limitation that the thread forces the screw into pre-determined positions, modifications have been made to allow screw positioning within a range of 30° (Non Contact Bridging, NCB®-DF, Zimmer). For the first time, this multicenter prospective randomized clinical trial (RCT) investigates the outcome of LISS® vs. NCB®-DF treatment following complex fractures of the distal femur.

Methods

Since June 2008, 27 patients with a fracture of the distal femur (AO ASIF 33-A-C and periprosthetic fractures) were enrolled in this study by four university trauma centres in southern Germany. Clinical (e.g. range of motion, Oxford knee score, Tegner score) and radiological (e.g. axis deviation, secondary loss of realignment) follow-ups were conducted one and six weeks, as well as three, six, and 12 months after the operation.

Results

This study comprises data of 27 patients (8 male, 19 female; 15 NCB®-DF, 12 LISS®). Polyaxial osteosynthesis using the NCB® system tended to result in better functional knee scores and a higher range of motion. Interestingly, fracture union tended to be more rapid using the polyaxial plating system.

Conclusions

We present the analysis of a multicenter prospective RCT to compare the monoaxial LISS® vs. the polyaxial NCB®-DF treatment following complex fractures of the distal femur. NCB®-DF treatment tended to result in better functional and radiological outcomes than LISS® treatment.

Level of Evidence

Level I
Literature
1.
go back to reference Martinet O, Cordey J, Harder Y, Maier A, Buhler M, Barraud GE (2000) The epidemiology of fractures of the distal femur. Injury 31(Suppl 3):C62–C63PubMedCrossRef Martinet O, Cordey J, Harder Y, Maier A, Buhler M, Barraud GE (2000) The epidemiology of fractures of the distal femur. Injury 31(Suppl 3):C62–C63PubMedCrossRef
2.
go back to reference Schandelmaier P, Gossling T, Partenheimer A, Krettek C (2002) Distal fractures of the femur. Chirurg 73:1221–1233PubMedCrossRef Schandelmaier P, Gossling T, Partenheimer A, Krettek C (2002) Distal fractures of the femur. Chirurg 73:1221–1233PubMedCrossRef
3.
go back to reference Kinzl LF (2000) Distal. In: Ruedi TP, Murphy WM (eds) AO Principles of fracture management. Thieme, New York, pp 469–480 Kinzl LF (2000) Distal. In: Ruedi TP, Murphy WM (eds) AO Principles of fracture management. Thieme, New York, pp 469–480
4.
go back to reference Partenheimer A, Gosling T, Muller M, Schirmer C, Kaab M, Matschke S, Ryf C, Renner N, Wiebking U, Krettek C (2007) Management of bicondylar fractures of the tibial plateau with unilateral fixed-angle plate fixation. Unfallchirurg 110:675–684PubMedCrossRef Partenheimer A, Gosling T, Muller M, Schirmer C, Kaab M, Matschke S, Ryf C, Renner N, Wiebking U, Krettek C (2007) Management of bicondylar fractures of the tibial plateau with unilateral fixed-angle plate fixation. Unfallchirurg 110:675–684PubMedCrossRef
5.
go back to reference Kregor PJ, Stannard J, Zlowodzki M, Cole PA, Alonso J (2001) Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results. Injury 32(Suppl 3):SC32–SC47PubMedCrossRef Kregor PJ, Stannard J, Zlowodzki M, Cole PA, Alonso J (2001) Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results. Injury 32(Suppl 3):SC32–SC47PubMedCrossRef
6.
go back to reference Cole PA, Zlowodzki M, Kregor PJ (2003) Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: indications, surgical technique and preliminary results of the UMC Clinical Trial. Injury 34(Suppl 1):A16–A29PubMedCrossRef Cole PA, Zlowodzki M, Kregor PJ (2003) Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: indications, surgical technique and preliminary results of the UMC Clinical Trial. Injury 34(Suppl 1):A16–A29PubMedCrossRef
7.
go back to reference Marti A, Fankhauser C, Frenk A, Cordey J, Gasser B (2001) Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures. J Orthop Trauma 15:482–487PubMedCrossRef Marti A, Fankhauser C, Frenk A, Cordey J, Gasser B (2001) Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures. J Orthop Trauma 15:482–487PubMedCrossRef
8.
go back to reference Chakravarthy J, Bansal R, Cooper J (2007) Locking plate osteosynthesis for Vancouver type B1 and type C periprosthetic fractures of femur: a report on 12 patients. Injury 38:725–733PubMedCrossRef Chakravarthy J, Bansal R, Cooper J (2007) Locking plate osteosynthesis for Vancouver type B1 and type C periprosthetic fractures of femur: a report on 12 patients. Injury 38:725–733PubMedCrossRef
9.
go back to reference Holzapfel BM, Prodinger PM, Hoberg M, Meffert R, Rudert M, Gradinger R (2010) Periprosthetic fractures after total hip arthroplasty: classification, diagnosis and therapy strategies. Orthopade 39:519–535PubMedCrossRef Holzapfel BM, Prodinger PM, Hoberg M, Meffert R, Rudert M, Gradinger R (2010) Periprosthetic fractures after total hip arthroplasty: classification, diagnosis and therapy strategies. Orthopade 39:519–535PubMedCrossRef
10.
go back to reference Otto RJ, Moed BR, Bledsoe JG (2009) Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures. J Orthop Trauma 23:645–652PubMedCrossRef Otto RJ, Moed BR, Bledsoe JG (2009) Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures. J Orthop Trauma 23:645–652PubMedCrossRef
11.
go back to reference El-Zayat BF, Zettl R, Efe T, Kruger A, Eisenberg F, Ruchholtz S (2012) Minimally invasive treatment of geriatric and osteoporotic femur fractures with polyaxial locking implants (NCB-DF(R)). Unfallchirurg 115:134–144PubMedCrossRef El-Zayat BF, Zettl R, Efe T, Kruger A, Eisenberg F, Ruchholtz S (2012) Minimally invasive treatment of geriatric and osteoporotic femur fractures with polyaxial locking implants (NCB-DF(R)). Unfallchirurg 115:134–144PubMedCrossRef
12.
go back to reference Hanschen M, Biberthaler P (2013) Mono- versus polyaxial locking plates. Unfallchirurg 116:733–741PubMedCrossRef Hanschen M, Biberthaler P (2013) Mono- versus polyaxial locking plates. Unfallchirurg 116:733–741PubMedCrossRef
13.
go back to reference Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res 198:43–49 Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res 198:43–49
14.
go back to reference Whitehouse SL, Blom AW, Taylor AH, Pattison GT, Bannister GC (2005) The Oxford knee score; problems and pitfalls. Knee 12:287–291PubMedCrossRef Whitehouse SL, Blom AW, Taylor AH, Pattison GT, Bannister GC (2005) The Oxford knee score; problems and pitfalls. Knee 12:287–291PubMedCrossRef
15.
go back to reference Rasmussen PS (1973) Tibial condylar fractures. Impairment of knee joint stability as an indication for surgical treatment. J Bone Joint Surg Am 55:1331–1350PubMed Rasmussen PS (1973) Tibial condylar fractures. Impairment of knee joint stability as an indication for surgical treatment. J Bone Joint Surg Am 55:1331–1350PubMed
16.
go back to reference Sommer C, Babst R, Muller M, Hanson B (2004) Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma 18:571–577PubMedCrossRef Sommer C, Babst R, Muller M, Hanson B (2004) Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma 18:571–577PubMedCrossRef
17.
go back to reference Miranda MA (2007) Locking plate technology and its role in osteoporotic fractures. Injury 38(Suppl 3):S35–S39PubMedCrossRef Miranda MA (2007) Locking plate technology and its role in osteoporotic fractures. Injury 38(Suppl 3):S35–S39PubMedCrossRef
18.
go back to reference Schutz M, Sudkamp NP (2003) Revolution in plate osteosynthesis: new internal fixator systems. J Orthop Sci 8:252–258PubMedCrossRef Schutz M, Sudkamp NP (2003) Revolution in plate osteosynthesis: new internal fixator systems. J Orthop Sci 8:252–258PubMedCrossRef
19.
go back to reference Luthi U, Rahn BA, Perren SM (1980) Area of contact between osteosynthesis plate and bone in internal fixation (author’s transl). Aktuelle Traumatol 10:131–136PubMed Luthi U, Rahn BA, Perren SM (1980) Area of contact between osteosynthesis plate and bone in internal fixation (author’s transl). Aktuelle Traumatol 10:131–136PubMed
20.
go back to reference Zettl R, Muller T, Topp T, Lewan U, Kruger A, Kuhne C, Ruchholtz S (2011) Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures. Int Orthop 35:1245–1250PubMedCentralPubMedCrossRef Zettl R, Muller T, Topp T, Lewan U, Kruger A, Kuhne C, Ruchholtz S (2011) Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures. Int Orthop 35:1245–1250PubMedCentralPubMedCrossRef
21.
go back to reference Ockert B, Braunstein V, Kirchhoff C, Korner M, Kirchhoff S, Kehr K, Mutschler W, Biberthaler P (2010) Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study. J Trauma 69:1545–1551PubMedCrossRef Ockert B, Braunstein V, Kirchhoff C, Korner M, Kirchhoff S, Kehr K, Mutschler W, Biberthaler P (2010) Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study. J Trauma 69:1545–1551PubMedCrossRef
22.
go back to reference Konstantinidis L, Hauschild O, Beckmann NA, Hirschmuller A, Sudkamp NP, Helwig P (2010) Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: biomechanical comparison studies on cadaveric bones. Injury 41:1256–1261PubMedCrossRef Konstantinidis L, Hauschild O, Beckmann NA, Hirschmuller A, Sudkamp NP, Helwig P (2010) Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: biomechanical comparison studies on cadaveric bones. Injury 41:1256–1261PubMedCrossRef
23.
go back to reference Roderer G, AbouElsoud M, Gebhard F, Claes L, Aschoff AJ, Kinzl L (2010) Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus. Unfallchirurg 113:133–138PubMedCrossRef Roderer G, AbouElsoud M, Gebhard F, Claes L, Aschoff AJ, Kinzl L (2010) Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus. Unfallchirurg 113:133–138PubMedCrossRef
Metadata
Title
Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
Authors
Marc Hanschen
Ina M. Aschenbrenner
Kai Fehske
Sonja Kirchhoff
Leonhard Keil
Boris M. Holzapfel
Sebastian Winkler
Bernd Fuechtmeier
Rainer Neugebauer
Sven Luehrs
Ulrich Liener
Peter Biberthaler
Publication date
01-04-2014
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 4/2014
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-2210-0

Other articles of this Issue 4/2014

International Orthopaedics 4/2014 Go to the issue