Skip to main content
Top
Published in: International Orthopaedics 4/2010

01-04-2010 | Original Paper

In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty

Authors: Angela L. Moynihan, Kartik M. Varadarajan, George R. Hanson, Sang-Eun Park, Kyung Wook Nha, Jeremy F. Suggs, Todd Johnson, Guoan Li

Published in: International Orthopaedics | Issue 4/2010

Login to get access

Abstract

The objective of this study was to investigate biomechanics of TKA patients during high flexion. Six patients (seven knees) with a posterior-substituting TKA and weight-bearing flexion >130° were included in the study. The six degree-of-freedom kinematics, tibiofemoral contact, and cam-post contact were measured during a deep knee bend using dual-plane fluoroscopy. The patients achieved average weight-bearing flexion of 139.5 ± 4.5°. Posterior femoral translation and internal tibial rotation increased steadily beyond 90° flexion, and a sharp increase in varus rotation was noted at maximum flexion. Initial cam-post engagement was observed at 100.3 ± 6.7° flexion. Five knees had cam-post disengagement before maximum flexion. Lateral femoral condylar lift-off was found in five out of seven knees at maximum flexion, and medial condylar lift-off was found in one knee. Future studies should investigate if the kinematic characteristics of posterior-substituting TKA knees noted in this study are causative factors of high knee flexion.
Appendix
Available only for authorised users
Literature
1.
go back to reference Andriacchi TP, Dyrby CO, Johnson TS (2003) The use of functional analysis in evaluating knee kinematics. Clin Orthop Relat Res 410:44–53CrossRefPubMed Andriacchi TP, Dyrby CO, Johnson TS (2003) The use of functional analysis in evaluating knee kinematics. Clin Orthop Relat Res 410:44–53CrossRefPubMed
2.
go back to reference Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Jt Surg Br 84:50–53CrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Jt Surg Br 84:50–53CrossRef
3.
go back to reference Chandran N, Amirouche F, Gonzalez MH, Hilton KM, Barmada R, Goldstein W (2008) Optimisation of the posterior stabilised tibial post for greater femoral rollback after total knee arthroplasty—a finite element analysis. Int Orthop [Epub ahead of print] Chandran N, Amirouche F, Gonzalez MH, Hilton KM, Barmada R, Goldstein W (2008) Optimisation of the posterior stabilised tibial post for greater femoral rollback after total knee arthroplasty—a finite element analysis. Int Orthop [Epub ahead of print]
4.
go back to reference Coughlin KM, Incavo SJ, Doohen RR, Gamada K, Banks S, Beynnon BD (2007) Kneeling kinematics after total knee arthroplasty: anterior-posterior contact position of a standard and a high-flex tibial insert design. J Arthroplast 22:160–165CrossRef Coughlin KM, Incavo SJ, Doohen RR, Gamada K, Banks S, Beynnon BD (2007) Kneeling kinematics after total knee arthroplasty: anterior-posterior contact position of a standard and a high-flex tibial insert design. J Arthroplast 22:160–165CrossRef
5.
go back to reference Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Jt Surg Br 88:1016–1021CrossRef Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Jt Surg Br 88:1016–1021CrossRef
6.
go back to reference Dennis DA, Komistek RD, Scuderi GR, Zingde S (2007) Factors affecting flexion after total knee arthroplasty. Clin Orthop Relat Res 464:53–60PubMed Dennis DA, Komistek RD, Scuderi GR, Zingde S (2007) Factors affecting flexion after total knee arthroplasty. Clin Orthop Relat Res 464:53–60PubMed
7.
go back to reference Dennis DA, Komistek RD, Walker SA, Cheal EJ, Stiehl JB (2001) Femoral condylar lift-off in vivo in total knee arthroplasty. J Bone Jt Surg Br 83:33–39CrossRef Dennis DA, Komistek RD, Walker SA, Cheal EJ, Stiehl JB (2001) Femoral condylar lift-off in vivo in total knee arthroplasty. J Bone Jt Surg Br 83:33–39CrossRef
8.
go back to reference Hamai S, Miura H, Higaki H, Matsuda S, Shimoto T, Sasaki K, Yoshizumi M, Okazaki K, Tsukamoto N, Iwamoto Y (2008) Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties. J Orthop Res 26:435–442CrossRefPubMed Hamai S, Miura H, Higaki H, Matsuda S, Shimoto T, Sasaki K, Yoshizumi M, Okazaki K, Tsukamoto N, Iwamoto Y (2008) Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties. J Orthop Res 26:435–442CrossRefPubMed
9.
go back to reference Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Jt Surg Br 89:1457–1461CrossRef Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Jt Surg Br 89:1457–1461CrossRef
10.
go back to reference Hanson GR, Park SE, Suggs JF, Moynihan AL, Nha KW, Freiberg AA, Li G (2007) In vivo kneeling biomechanics after posterior stabilized total knee arthroplasty. J Orthop Sci 12:476–483CrossRefPubMed Hanson GR, Park SE, Suggs JF, Moynihan AL, Nha KW, Freiberg AA, Li G (2007) In vivo kneeling biomechanics after posterior stabilized total knee arthroplasty. J Orthop Sci 12:476–483CrossRefPubMed
11.
go back to reference Hanson GR, Suggs JF, Freiberg AA, Durbhakula S, Li G (2006) Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res 24:974–981CrossRefPubMed Hanson GR, Suggs JF, Freiberg AA, Durbhakula S, Li G (2006) Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res 24:974–981CrossRefPubMed
12.
go back to reference Hemmerich A, Brown H, Smith S, Marthandam SS, Wyss UP (2006) Hip, knee, and ankle kinematics of high range of motion activities of daily living. J Orthop Res 24:770–781CrossRefPubMed Hemmerich A, Brown H, Smith S, Marthandam SS, Wyss UP (2006) Hip, knee, and ankle kinematics of high range of motion activities of daily living. J Orthop Res 24:770–781CrossRefPubMed
13.
go back to reference Jennings LM, Bell CJ, Ingham E, Komistek RD, Stone MH, Fisher J (2007) The influence of femoral condylar lift-off on the wear of artificial knee joints. Proc Inst Mech Eng [H] 221:305–314 Jennings LM, Bell CJ, Ingham E, Komistek RD, Stone MH, Fisher J (2007) The influence of femoral condylar lift-off on the wear of artificial knee joints. Proc Inst Mech Eng [H] 221:305–314
14.
go back to reference Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Jt Surg Br 90:1304–1310CrossRef Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Jt Surg Br 90:1304–1310CrossRef
15.
go back to reference Lee SY, Matsui N, Kurosaka M, Komistek RD, Mahfouz M, Dennis DA et al (2005) A posterior-stabilized total knee arthroplasty shows condylar lift-off during deep knee bends. Clin Orthop Relat Res 435:181–184CrossRefPubMed Lee SY, Matsui N, Kurosaka M, Komistek RD, Mahfouz M, Dennis DA et al (2005) A posterior-stabilized total knee arthroplasty shows condylar lift-off during deep knee bends. Clin Orthop Relat Res 435:181–184CrossRefPubMed
16.
go back to reference Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T et al (2002) Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study. Clin Orthop Relat Res 404:214–225CrossRefPubMed Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T et al (2002) Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study. Clin Orthop Relat Res 404:214–225CrossRefPubMed
17.
go back to reference Li G, Most E, Sultan PG, Schule S, Zayontz S, Park SE, Rubash HE (2004) Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: an in vitro robotic experimental investigation. J Bone Jt Surg Am 86:1721–1729 Li G, Most E, Sultan PG, Schule S, Zayontz S, Park SE, Rubash HE (2004) Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: an in vitro robotic experimental investigation. J Bone Jt Surg Am 86:1721–1729
18.
go back to reference Li G, Papannagari R, Li M, Bingham J, Nha KW, Allred D et al (2007) Effect of posterior cruciate ligament deficiency on in vivo translation and rotation of the knee during weightbearing flexion. Am J Sports Med 36:474–479CrossRefPubMed Li G, Papannagari R, Li M, Bingham J, Nha KW, Allred D et al (2007) Effect of posterior cruciate ligament deficiency on in vivo translation and rotation of the knee during weightbearing flexion. Am J Sports Med 36:474–479CrossRefPubMed
19.
go back to reference Li G, Suggs J, Hanson G, Durbhakula S, Johnson T, Freiberg A (2006) Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty. J Bone Jt Surg Am 88:395–402CrossRef Li G, Suggs J, Hanson G, Durbhakula S, Johnson T, Freiberg A (2006) Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty. J Bone Jt Surg Am 88:395–402CrossRef
20.
go back to reference Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24:191–198CrossRefPubMed Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24:191–198CrossRefPubMed
21.
go back to reference Ng FY, Wong HL, Yau WP, Chiu KY, Tang WM (2008) Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement. Int Orthop 32:795–798CrossRefPubMed Ng FY, Wong HL, Yau WP, Chiu KY, Tang WM (2008) Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement. Int Orthop 32:795–798CrossRefPubMed
22.
go back to reference Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop Relat Res 461:143–152PubMed Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop Relat Res 461:143–152PubMed
23.
go back to reference Scuderi GR, Komistek RD, Dennis DA, Insall JN (2003) The impact of femoral component rotational alignment on condylar lift-off. Clin Orthop Relat Res 410:148–154CrossRefPubMed Scuderi GR, Komistek RD, Dennis DA, Insall JN (2003) The impact of femoral component rotational alignment on condylar lift-off. Clin Orthop Relat Res 410:148–154CrossRefPubMed
24.
go back to reference Suggs JF (2007) Investigation of in-vivo total knee arthroplasty biomechanics using a dual fluoroscopic imaging system. Dissertation, Massachusetts Institute of Technology, Cambridge, MA Suggs JF (2007) Investigation of in-vivo total knee arthroplasty biomechanics using a dual fluoroscopic imaging system. Dissertation, Massachusetts Institute of Technology, Cambridge, MA
25.
go back to reference Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296CrossRefPubMed Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296CrossRefPubMed
Metadata
Title
In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty
Authors
Angela L. Moynihan
Kartik M. Varadarajan
George R. Hanson
Sang-Eun Park
Kyung Wook Nha
Jeremy F. Suggs
Todd Johnson
Guoan Li
Publication date
01-04-2010
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 4/2010
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0777-2

Other articles of this Issue 4/2010

International Orthopaedics 4/2010 Go to the issue