Skip to main content
Top
Published in: International Orthopaedics 4/2009

01-08-2009 | Original Paper

Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty

Authors: A. J. Graydon, S. Malak, I. A. Anderson, R. P. Pitto

Published in: International Orthopaedics | Issue 4/2009

Login to get access

Abstract

The objective of this study was to develop a method to assess the accuracy of an electromagnetic technology image-free navigation system for total knee arthroplasty in a leg with normal or abnormal mechanical alignment. An acrylic phantom leg was constructed to simulate tibia and femur deformation. Determination of actual leg alignment was achieved using a digital caliper unit. In the setting of normal alignment, the mean error of the system characterised as the difference between the measured computer navigation and digital caliper angles ranged between 0.8° (frontal plane) and 1.5° (lateral plane). In the setting of abnormal alignment, the mean error ranged between 0.4° (frontal plane) and 1.6° (lateral plane). Deformity had no demonstrable effect on accuracy. The study demonstrates satisfactory in vitro system accuracy in both normal and abnormal leg mechanical alignment settings.
Literature
1.
go back to reference Alan R, Shin M, Tria A (2007) Initial experience with electromagnetic navigation in total knee arthroplasty. J Knee Surg 20:152–157PubMed Alan R, Shin M, Tria A (2007) Initial experience with electromagnetic navigation in total knee arthroplasty. J Knee Surg 20:152–157PubMed
2.
go back to reference Bauwens K, Matthes G, Wich M (2007) Navigated total knee replacement—a meta-analysis. J Bone Joint Surg [Am] 89-A:261–269CrossRef Bauwens K, Matthes G, Wich M (2007) Navigated total knee replacement—a meta-analysis. J Bone Joint Surg [Am] 89-A:261–269CrossRef
3.
go back to reference Bragdon CR, Malchau H, Yuan X et al (2002) Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. J Orthop Res 20:688–695PubMedCrossRef Bragdon CR, Malchau H, Yuan X et al (2002) Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. J Orthop Res 20:688–695PubMedCrossRef
4.
go back to reference Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomised control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomised control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef
5.
go back to reference Hakker RG, Stockheim M, Kamp M et al (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Rel Res 433:152–159 Hakker RG, Stockheim M, Kamp M et al (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Rel Res 433:152–159
6.
go back to reference Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369PubMedCrossRef Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369PubMedCrossRef
7.
go back to reference Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomized study. J Bone Joint Surg Br 89:471–476PubMedCrossRef Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomized study. J Bone Joint Surg Br 89:471–476PubMedCrossRef
8.
go back to reference Lionberger R (2006) The attraction of electromagnetic computer-assisted navigation in orthopaedic surgery. In: Stiehl JB, Konermann W, Hacker R (eds) Navigation and MIS in orthopaedic surgery. Springer, Heidelberg, pp 44–53 Lionberger R (2006) The attraction of electromagnetic computer-assisted navigation in orthopaedic surgery. In: Stiehl JB, Konermann W, Hacker R (eds) Navigation and MIS in orthopaedic surgery. Springer, Heidelberg, pp 44–53
9.
go back to reference Maletsky LP, Rullkoetter PJ (2005) The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 38:349–55PubMedCrossRef Maletsky LP, Rullkoetter PJ (2005) The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 38:349–55PubMedCrossRef
10.
go back to reference Matziolis G, Krocker D, Weiss U et al (2007) A prospective, randomised study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U et al (2007) A prospective, randomised study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
11.
go back to reference Pitto RP, Graydon AJ, Bradley L, et al (2006) Accuracy of a computer assisted navigation system for total knee replacement. J Bone Joint Surg [Br] 88:601–605 Pitto RP, Graydon AJ, Bradley L, et al (2006) Accuracy of a computer assisted navigation system for total knee replacement. J Bone Joint Surg [Br] 88:601–605
12.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Rel Res 299:153–156 Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Rel Res 299:153–156
13.
go back to reference Robinson M, Eckhoff DG, Reinig KD et al (2006) Variability of landmark identification in total knee arthroplasty. Clin Orthop Rel Res 442:57–62CrossRef Robinson M, Eckhoff DG, Reinig KD et al (2006) Variability of landmark identification in total knee arthroplasty. Clin Orthop Rel Res 442:57–62CrossRef
14.
go back to reference Schleicher I, Donnelly W, Crawford R (2004) Results of acetabular component positioning with an imageless hip navigation system, using a mechanical hip device. J Bone Joint Surg [Br] 86-B:474 Schleicher I, Donnelly W, Crawford R (2004) Results of acetabular component positioning with an imageless hip navigation system, using a mechanical hip device. J Bone Joint Surg [Br] 86-B:474
15.
go back to reference Sikorski JM, Chauhan S (2003) Computer-assisted orthopaedic surgery: do we need CAOS? J Bone Joint Surg [Br] 85-B:319–323CrossRef Sikorski JM, Chauhan S (2003) Computer-assisted orthopaedic surgery: do we need CAOS? J Bone Joint Surg [Br] 85-B:319–323CrossRef
16.
go back to reference Slomczykowski M, Edwards PJ, Penney GP (2004) A cadaver study to assess the accuracy of CT-free guided knee replacement. Orthop Res Soc Transactions 29:1378 Slomczykowski M, Edwards PJ, Penney GP (2004) A cadaver study to assess the accuracy of CT-free guided knee replacement. Orthop Res Soc Transactions 29:1378
17.
go back to reference Sparmann M, Wolke B, Czupalla H (2003) Positioning of total knee arthroplasty with and without navigation support. J Bone Joint Surg [Br] 85-B:830–835 Sparmann M, Wolke B, Czupalla H (2003) Positioning of total knee arthroplasty with and without navigation support. J Bone Joint Surg [Br] 85-B:830–835
18.
go back to reference Spencer JM, Chauhan SK, Sloan K et al (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89:477–480PubMedCrossRef Spencer JM, Chauhan SK, Sloan K et al (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89:477–480PubMedCrossRef
19.
go back to reference Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84(Supp 2):90–98 Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84(Supp 2):90–98
21.
go back to reference Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Rel Res 428:131–139CrossRef Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Rel Res 428:131–139CrossRef
Metadata
Title
Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty
Authors
A. J. Graydon
S. Malak
I. A. Anderson
R. P. Pitto
Publication date
01-08-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 4/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0586-z

Other articles of this Issue 4/2009

International Orthopaedics 4/2009 Go to the issue