Skip to main content
Top
Published in: International Orthopaedics 1/2009

01-02-2009 | Original Paper

Assessment of radiolucent lines in cemented shoulder hemi-arthroplasties: study of concordance and reproducibility

Authors: Carlos Torrens, Santos Martínez-Díaz, Aina Ruiz, Alberto Gines, Enrique Cáceres

Published in: International Orthopaedics | Issue 1/2009

Login to get access

Abstract

We report on the concordance and reproducibility of the evaluation of radiolucent lines in the humeral component of shoulder arthroplasty. Thirty-two shoulder prostheses were assessed independently, on two occasions, by five observers. The level of inter- and intra-observer agreement was calculated using the kappa statistic. Intra-observer agreement: the overall kappa values ranged from 0 to 0.6, meaning poor, fair and moderate agreement levels. Inter-observer agreement: when the anteroposterior (AP) views were analysed, the values obtained for the bone–cement interface ranged from 0.290 to 0.539, meaning a poor-to-moderate agreement. For the cement–implant interface, the values ranged from 0.064 to 0.684, meaning a poor-to-good agreement. When radiolucent lines of the humeral component were analysed, inter-observer agreement proved to be as low as that obtained when total hip or knee components were analysed. Intra-observer agreement showed better results.
Literature
1.
go back to reference Bach CM, Bieremann R, Goebel G, Mayer E, Rachbauer F (2005) Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthop Relat Res 433:183–188CrossRef Bach CM, Bieremann R, Goebel G, Mayer E, Rachbauer F (2005) Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthop Relat Res 433:183–188CrossRef
2.
go back to reference Boileau P, Avidor C, Krishnan SG, Walch G, Kempf JF, Mole D (2002) Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study. J Shoulder Elbow Surg 11:351–359PubMedCrossRef Boileau P, Avidor C, Krishnan SG, Walch G, Kempf JF, Mole D (2002) Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study. J Shoulder Elbow Surg 11:351–359PubMedCrossRef
3.
go back to reference Cofield RH (1984) Total shoulder arthroplasty with the Neer prosthesis. J Bone Joint Surg Am 66:899–906PubMed Cofield RH (1984) Total shoulder arthroplasty with the Neer prosthesis. J Bone Joint Surg Am 66:899–906PubMed
4.
go back to reference Edwards TB, Kadakia NR, Boulahia A, Kempf JF, Boileau P, Némoz C, Walch G (2003) A comparison of hemiarthroplasty and total shoulder arthroplasty in the treatment of primary glenohumeral osteoarthritis: results of a multicenter study. J Shoulder Elbow Surg 12:207–213PubMedCrossRef Edwards TB, Kadakia NR, Boulahia A, Kempf JF, Boileau P, Némoz C, Walch G (2003) A comparison of hemiarthroplasty and total shoulder arthroplasty in the treatment of primary glenohumeral osteoarthritis: results of a multicenter study. J Shoulder Elbow Surg 12:207–213PubMedCrossRef
5.
go back to reference Gruen T, McNeice G, Amstutz H (1979) “Modes of failure” of cemented stem-type femoral components. A radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen T, McNeice G, Amstutz H (1979) “Modes of failure” of cemented stem-type femoral components. A radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
6.
go back to reference Harvey EJ, Tanzer M, Bobyn JD (1998) Femoral cemented grading in total hip arthroplasty. J Arthroplasty 13:396–401PubMedCrossRef Harvey EJ, Tanzer M, Bobyn JD (1998) Femoral cemented grading in total hip arthroplasty. J Arthroplasty 13:396–401PubMedCrossRef
7.
go back to reference Hasan SS, Leith JM, Campbell B, Kapil R, Smith KL, Matsen III FA (2002) Characteristics of unsatisfactory shoulder arthroplasties. J Shoulder Elbow Surg 11:431–441PubMedCrossRef Hasan SS, Leith JM, Campbell B, Kapil R, Smith KL, Matsen III FA (2002) Characteristics of unsatisfactory shoulder arthroplasties. J Shoulder Elbow Surg 11:431–441PubMedCrossRef
8.
go back to reference Havig M, Kumar A, Carpenter W, Seiler J (1997) Assessment of radiolucent lines about the glenoid. J Bone Joint Surg Am 79:428–432PubMedCrossRef Havig M, Kumar A, Carpenter W, Seiler J (1997) Assessment of radiolucent lines about the glenoid. J Bone Joint Surg Am 79:428–432PubMedCrossRef
9.
go back to reference Iwaki H, Scott G, Freeman MAR (2002) The natural history and significance of radiolucent lines at a cemented femoral interface. J Bone Joint Surg Br 84:550–555PubMedCrossRef Iwaki H, Scott G, Freeman MAR (2002) The natural history and significance of radiolucent lines at a cemented femoral interface. J Bone Joint Surg Br 84:550–555PubMedCrossRef
10.
go back to reference Klepps S, Chiang AS, Miller S, Jiang CY, Hazrati Y, Flatow EL (2005) Incidence of early radiolucent glenoid lines in patients having total shoulder replacements. Clin Orthop Relat Res 435:118–125PubMedCrossRef Klepps S, Chiang AS, Miller S, Jiang CY, Hazrati Y, Flatow EL (2005) Incidence of early radiolucent glenoid lines in patients having total shoulder replacements. Clin Orthop Relat Res 435:118–125PubMedCrossRef
11.
go back to reference Klimkiewicz JJ, Iannotti JP, Rubash HE, Shanbhag AS (1998) Aseptic loosening of the humeral component in total shoulder arthroplasty. J Shoulder Elbow Surg 7:422–426PubMedCrossRef Klimkiewicz JJ, Iannotti JP, Rubash HE, Shanbhag AS (1998) Aseptic loosening of the humeral component in total shoulder arthroplasty. J Shoulder Elbow Surg 7:422–426PubMedCrossRef
12.
go back to reference Kneif D, Downing M, Ashcroft P, Gibson P, Knight D, Ledingham W, Hutchison J (2005) Peri-acetabular radiolucent lines. Inter- and intra-observer agreement on post-operative radiographs. Int Orthop 29:152–155PubMedCrossRef Kneif D, Downing M, Ashcroft P, Gibson P, Knight D, Ledingham W, Hutchison J (2005) Peri-acetabular radiolucent lines. Inter- and intra-observer agreement on post-operative radiographs. Int Orthop 29:152–155PubMedCrossRef
13.
go back to reference Landis JR, Koch CG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch CG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
14.
go back to reference Lazarus M, Jensen K, Southworth C, Matsen F (2002) The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84:1174–1182PubMed Lazarus M, Jensen K, Southworth C, Matsen F (2002) The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84:1174–1182PubMed
15.
go back to reference Matsen III FA, Iannotti JP, Rockwood CA (2003) Humeral fixation by press-fitting of a tapered metaphyseal stem. J Bone Joint Surg Am 85:304–308PubMed Matsen III FA, Iannotti JP, Rockwood CA (2003) Humeral fixation by press-fitting of a tapered metaphyseal stem. J Bone Joint Surg Am 85:304–308PubMed
16.
go back to reference Nagels J, Valstar ER, Stokdijk M, Rozing PM (2002) Patterns of loosening of the glenoid component. J Bone Joint Surg Br 84:83–87PubMedCrossRef Nagels J, Valstar ER, Stokdijk M, Rozing PM (2002) Patterns of loosening of the glenoid component. J Bone Joint Surg Br 84:83–87PubMedCrossRef
17.
go back to reference Neer CS, Watson KC, Stanton FJ (1982) Recent experience in total shoulder replacement. J Bone Joint Surg Am 64:319–337PubMed Neer CS, Watson KC, Stanton FJ (1982) Recent experience in total shoulder replacement. J Bone Joint Surg Am 64:319–337PubMed
18.
go back to reference Sanchez-Sotelo J, O’Driscoll SW, Torchia ME, Cofield RH, Rowland CM (2001) Radiographic assessment of cemented humeral components in shoulder arthroplasty. J Shoulder Elbow Surg 10:526–531PubMedCrossRef Sanchez-Sotelo J, O’Driscoll SW, Torchia ME, Cofield RH, Rowland CM (2001) Radiographic assessment of cemented humeral components in shoulder arthroplasty. J Shoulder Elbow Surg 10:526–531PubMedCrossRef
19.
go back to reference Sperling JW, Cofield RH, O’Driscoll SW, Torchia ME, Rowland CM (2000) Radiographic assessment of ingrowth total shoulder arthroplasty. J Shoulder Elbow Surg 9:507–513PubMedCrossRef Sperling JW, Cofield RH, O’Driscoll SW, Torchia ME, Rowland CM (2000) Radiographic assessment of ingrowth total shoulder arthroplasty. J Shoulder Elbow Surg 9:507–513PubMedCrossRef
20.
go back to reference Tigges S, Stiles R, Roberson R. (1994) Complications of hip arthroplasty causing periprosthetic radiolucency on plain radiographs. AJR Am J Roentgenol 162:1386–1391 Tigges S, Stiles R, Roberson R. (1994) Complications of hip arthroplasty causing periprosthetic radiolucency on plain radiographs. AJR Am J Roentgenol 162:1386–1391
21.
go back to reference Torchia ME, Cofield RH, Settergren CR (1997) Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Shoulder Elbow Surg 6:495–505PubMedCrossRef Torchia ME, Cofield RH, Settergren CR (1997) Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Shoulder Elbow Surg 6:495–505PubMedCrossRef
22.
go back to reference Walch G, Edwards B, Boulahia A, Boileau P, Mole D, Adeleine P (2002) The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines. Results of a multicenter study. J Bone Joint Surg Am 84:2186–2191PubMed Walch G, Edwards B, Boulahia A, Boileau P, Mole D, Adeleine P (2002) The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines. Results of a multicenter study. J Bone Joint Surg Am 84:2186–2191PubMed
23.
go back to reference Wirth MA, Rockwood CA Jr (1994) Complications of shoulder arthroplasty. Clin Orthop Relat Res 307:47–69PubMed Wirth MA, Rockwood CA Jr (1994) Complications of shoulder arthroplasty. Clin Orthop Relat Res 307:47–69PubMed
24.
go back to reference Yian EH, Werner CML, Nyffeler RW, Pfirrmann CW, Ramappa A, Sukthankar A, Gerber C (2005) Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. J Bone Joint Surg Am 87:1928–1936PubMedCrossRef Yian EH, Werner CML, Nyffeler RW, Pfirrmann CW, Ramappa A, Sukthankar A, Gerber C (2005) Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. J Bone Joint Surg Am 87:1928–1936PubMedCrossRef
Metadata
Title
Assessment of radiolucent lines in cemented shoulder hemi-arthroplasties: study of concordance and reproducibility
Authors
Carlos Torrens
Santos Martínez-Díaz
Aina Ruiz
Alberto Gines
Enrique Cáceres
Publication date
01-02-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 1/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-007-0452-4

Other articles of this Issue 1/2009

International Orthopaedics 1/2009 Go to the issue

Letter to the Editor

Osteochondritis dissecans