Abstract

Peri-acetabular radiolucent lines (RLLs) seen on “early” post-operative radiographs have been identified as a potential predictor of long-term implant performance. This study examines the inter- and intra-observer variation encountered when assessing such radiographs. Four consultant orthopaedic surgeons assessed the presence, extent and width of RLLs in 220 radiographs performed on 50 patients taken one to two weeks, six weeks, six months and one year following surgery. Inter-observer agreement was fair at 7–14 days but improved to moderate to good in films at six and 12 months. Intra-observer agreement was moderate to good at 7–10 days but again improved to good at 6 and 12 months. When only the presence or absence of RLLs was considered, both inter-observer and intra-observer agreement improved for both the six-month and one-year radiographs. This experiment shows that caution must be used for the interpretation of RLLs on hip radiographs taken during the very early post-operative period. We recommend that films taken at least six weeks to six months following surgery should be used for assessment to reduce observer variation. For optimum results, a single experienced observer should do the assessment with a simple classification.
Literature
1.
go back to reference Altman, DG (1990) Practical statistics for medial research. Chapman & Hall, London, pp 403–409 Altman, DG (1990) Practical statistics for medial research. Chapman & Hall, London, pp 403–409
2.
go back to reference Brand RA, Yoder SA, Pederson DR (1985) Interobserver variability in interpreting radiographic lucencies about total hip reconstructions. Clin Orthop 192:237–239 Brand RA, Yoder SA, Pederson DR (1985) Interobserver variability in interpreting radiographic lucencies about total hip reconstructions. Clin Orthop 192:237–239
3.
go back to reference Carlsson AS, Gentz CF (1984) Radiographic versus clinical loosening of the acetabular component in noninfected total hip arthroplasty. Clin Orthop 185:145–150 Carlsson AS, Gentz CF (1984) Radiographic versus clinical loosening of the acetabular component in noninfected total hip arthroplasty. Clin Orthop 185:145–150
4.
go back to reference DeLee J, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed DeLee J, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed
5.
go back to reference Gracia-Cimbrelo E, Diez-Vazquez V, Madero R, Munuera L (1997) Progression of radiolucent lines adjacent to the acetabular component and factors influencing migration after Charnley low-friction total hip arthroplasty. J Bone Joint Surg Am 79:1373–1380 Gracia-Cimbrelo E, Diez-Vazquez V, Madero R, Munuera L (1997) Progression of radiolucent lines adjacent to the acetabular component and factors influencing migration after Charnley low-friction total hip arthroplasty. J Bone Joint Surg Am 79:1373–1380
6.
go back to reference Hodgkinson JP, Maskell AP, Paul A, Wroblewski BM (1993) Flanged acetabular components in cemented CHarnley hip arthroplasty. Ten-year follow up of 350 patients. J Bone Joint Surg Br 75:464–467 Hodgkinson JP, Maskell AP, Paul A, Wroblewski BM (1993) Flanged acetabular components in cemented CHarnley hip arthroplasty. Ten-year follow up of 350 patients. J Bone Joint Surg Br 75:464–467
7.
go back to reference Kavanagh BF, Dewitz MA, Ilstrup DM, Stauffer RN, Coventry MB (1989) Charnley total hip arthroplasty with cement, fifteen-year result. J Bone Joint Surg Am 71:1496–1503 Kavanagh BF, Dewitz MA, Ilstrup DM, Stauffer RN, Coventry MB (1989) Charnley total hip arthroplasty with cement, fifteen-year result. J Bone Joint Surg Am 71:1496–1503
8.
go back to reference Kelly AJ, Lee MB, Wong NS, Smith EJ, Learmonth ID (1996) Poor reproducibiliity on radiographic grading of femoral cementing technique in total hip arthroplasty. J Arthroplast 11:525–528 Kelly AJ, Lee MB, Wong NS, Smith EJ, Learmonth ID (1996) Poor reproducibiliity on radiographic grading of femoral cementing technique in total hip arthroplasty. J Arthroplast 11:525–528
9.
go back to reference Kobayashi S, Terayama K (1990) Radiology of low friction arthroplasty of the hip, a comparison of socket fixation technique. J Bone Joint Surg Br 72:439–443 Kobayashi S, Terayama K (1990) Radiology of low friction arthroplasty of the hip, a comparison of socket fixation technique. J Bone Joint Surg Br 72:439–443
10.
go back to reference McCaskie AW, Brown AR, Thompson JR, Gregg PJ (1996) Radiological evaluation of the interfaces after cemented total hip replacement. Interobserver and intraobserver agreement. J Bone Joint Surg Br 78:191–194 McCaskie AW, Brown AR, Thompson JR, Gregg PJ (1996) Radiological evaluation of the interfaces after cemented total hip replacement. Interobserver and intraobserver agreement. J Bone Joint Surg Br 78:191–194
11.
go back to reference Ranawat CS, Deshmukh RG, Peters LE, Umlas ME (1995) Prediction of the long-term durability of all-polyethylene cemented sockets. Clin Orthop 317:89–105 Ranawat CS, Deshmukh RG, Peters LE, Umlas ME (1995) Prediction of the long-term durability of all-polyethylene cemented sockets. Clin Orthop 317:89–105
12.
go back to reference Reckling FW, Asher MA, Dillon WL (1997) A longitudinal study of the radiolucent line at the bone–cement interface following total joint-replacement procedures. J Bone Joint Surg Am 59:355–358 Reckling FW, Asher MA, Dillon WL (1997) A longitudinal study of the radiolucent line at the bone–cement interface following total joint-replacement procedures. J Bone Joint Surg Am 59:355–358
13.
go back to reference Ritter MA, Zhou H, Keating CM, Keating EM, Faris PM, Meding JB, Berend ME (1999) Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br 81:982–986 Ritter MA, Zhou H, Keating CM, Keating EM, Faris PM, Meding JB, Berend ME (1999) Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br 81:982–986
14.
go back to reference Robinson PJA (1997) Radiology’s Achilles’ heel: error and variation in the interpretation of the Roentgen image. Br J Radiol 70:1085–1098 Robinson PJA (1997) Radiology’s Achilles’ heel: error and variation in the interpretation of the Roentgen image. Br J Radiol 70:1085–1098
15.
go back to reference Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O’Connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH (1992) The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clin Orthop 274:60–78 Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O’Connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH (1992) The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clin Orthop 274:60–78
16.
go back to reference Schmalzried TP, Maloney WJ , Jasty M, Kwong LM, Harris WH (1993) Autopsy studies of the bone–cement interface in well-fixed cemented total hip arthroplasties. J Arthroplast 8:179–188 Schmalzried TP, Maloney WJ , Jasty M, Kwong LM, Harris WH (1993) Autopsy studies of the bone–cement interface in well-fixed cemented total hip arthroplasties. J Arthroplast 8:179–188
17.
go back to reference Stauffer RN (1988) Ten-year follow-up study of total hip replacement with particular reference to roentgenographic loosening of the components. J Bone Joint Surg Am 64:983–990 Stauffer RN (1988) Ten-year follow-up study of total hip replacement with particular reference to roentgenographic loosening of the components. J Bone Joint Surg Am 64:983–990
Metadata
Title
Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs
Authors
D. Kneif
M. Downing
G. P. Ashcroft
P. Gibson
D. Knight
W. Ledingham
J. Hutchison
Publication date
01-06-2005
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 3/2005
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-005-0644-8

Other articles of this Issue 3/2005

International Orthopaedics 3/2005 Go to the issue