01-08-2021 | Tympanotomy | Interventional Radiology

Can procedure time for paracentesis be optimized based on bottle selection?

Authors: William P. Perry, Joshua J. Barrett, Michelle Secic, Wendy L. Ehieli, Richard A. Leder, Daniele Marin, Rendon C. Nelson, Rajan T. Gupta

Published in: Abdominal Radiology | Issue 8/2021

Login to get access

Abstract

Purpose

The purpose of our study was to assess if plastic containers could decrease the overall procedure time for paracentesis relative to more commonly used glass containers.

Methods

In this IRB exempt study, initial pilot data comparing filling time of glass and plastic containers in an ex vivo setting under identical conditions revealed power calculations that n = 37 patients per group would be needed to achieve standard deviation (SD) = 60 s, difference (diff) = 40 s, two-tailed alpha-level 0.05, and power 80%. Total of 43 patients (93 containers) were enrolled and randomized to glass or plastic bottles at enrollment. Timing of bottle filling was assessed using standardized sonographic screen captures.

Results

An interim look at statistics at n = 20 patients indicated that original conjectures from pilot data were conservative and smaller sample size was sufficient to stop the study and conduct the analyses. Specifically, SD = 54 s, diff = 49 s, two-tailed alpha-level 0.05, and power 80% required n = 21 patients per group. Plastic containers had a statistically significantly lower average filling time per bottle (162.7 ± 53.3 s) compared to glass (212.2 ± 50.4 s) (p = 0.003). Viscosity was calculated for each specimen and did not affect the statistical significance of the results (p = 0.32).

Conclusion

Plastic containers have 50 s time savings of per bottle filling time as compared to glass bottles as theorized based on their faster flow rate. This holds true in both an ex vivo setting and in patients and can have important downstream impacts on patient throughput, provider efficiency and system wide cost savings.
Literature
3.
go back to reference Sanyal AJ, Bajaj JS, Shaw J (2010) Paracentesis. In: Ascites, Hyponatremia and Hepatorenal Syndrome: Progress in Treatment. In: Gerbes AL (ed) Front Gastrointest Res, vol 28. Karger, Basel, pp 23-31 Sanyal AJ, Bajaj JS, Shaw J (2010) Paracentesis. In: Ascites, Hyponatremia and Hepatorenal Syndrome: Progress in Treatment. In: Gerbes AL (ed) Front Gastrointest Res, vol 28. Karger, Basel, pp 23-31
5.
go back to reference Frosch R, Gallopoulos N (1989) Strategies for Manufacturing. Scientific American 261 (3):144-153CrossRef Frosch R, Gallopoulos N (1989) Strategies for Manufacturing. Scientific American 261 (3):144-153CrossRef
Metadata
Title
Can procedure time for paracentesis be optimized based on bottle selection?
Authors
William P. Perry
Joshua J. Barrett
Michelle Secic
Wendy L. Ehieli
Richard A. Leder
Daniele Marin
Rendon C. Nelson
Rajan T. Gupta
Publication date
01-08-2021
Publisher
Springer US
Published in
Abdominal Radiology / Issue 8/2021
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-021-03033-8

Other articles of this Issue 8/2021

Abdominal Radiology 8/2021 Go to the issue