Skip to main content
Top
Published in: Abdominal Radiology 9/2020

Open Access 01-09-2020 | Portal Hypertension | Hepatobiliary

Portosystemic shunt surgery in the era of TIPS: imaging-based planning of the surgical approach

Authors: Uli Fehrenbach, Safak Gül-Klein, Miguel de Sousa Mendes, Ingo Steffen, Julienne Stern, Dominik Geisel, Gero Puhl, Timm Denecke

Published in: Abdominal Radiology | Issue 9/2020

Login to get access

Abstract

Purpose

With the spread of transjugular intrahepatic portosystemic shunts (TIPS), portosystemic shunt surgery (PSSS) has decreased and leaves more complex patients with great demands for accurate preoperative planning. The aim was to evaluate the role of imaging for predicting the most suitable PSSS approach.

Material and methods

Forty-four patients who underwent PSSS (2002 to 2013) were examined by contrast-enhanced CT (n = 33) and/or MRI (n = 15) prior to surgery. Imaging was analyzed independently by two observers (O1 and O2) with different levels of experience (O1 > O2). They recommended two shunting techniques (vessels and anastomotic variant) for each patient and ranked them according to their appropriateness and complexity. Findings were compared with the actually performed shunt procedure and its outcome.

Results

The first two choices taken together covered the performed PSSS regarding vessels in 88%/100% (CT/MRI, O1) and 76%/73% (O2); and vessels + anastomosis in 79%/73% (O1) and 67%/60% (O2). The prediction of complex surgical procedures (resection of interposing structures, additional thrombectomy, use of a collateral vessel, and use of a graft interposition) was confirmed in 87%, resulting in 80% sensitivity and 96% specificity. Larger shunt vessel distances were associated with therapy failure (p = 0.030) and a vessel distance of ≥ 20 mm was identified as optimal cutoff, in which a graft interposition was used. There was no significant difference between MRI and CT in predicting the intraoperative decisions (p = 0.294 to 1.000).

Conclusion

Preoperative imaging and an experienced radiologist can guide surgeons in PSSS. CT and MRI provide the information necessary to identify technically feasible variants and complicating factors.
Appendix
Available only for authorised users
Literature
1.
go back to reference Knechtle SJ, D’Alessandro AM, Armbrust MJ, Musat A, Kalayoglu M (1999) Surgical portosystemic shunts for treatment of portal hypertensive bleeding: outcome and effect on liver function. Surgery 126 (4):708–711; discussion 711–703 Knechtle SJ, D’Alessandro AM, Armbrust MJ, Musat A, Kalayoglu M (1999) Surgical portosystemic shunts for treatment of portal hypertensive bleeding: outcome and effect on liver function. Surgery 126 (4):708–711; discussion 711–703
9.
go back to reference Procopet B, Tantau M, Bureau C (2013) Are there any alternative methods to hepatic venous pressure gradient in portal hypertension assessment? Journal of gastrointestinal and liver diseases : JGLD 22 (1):73–78PubMed Procopet B, Tantau M, Bureau C (2013) Are there any alternative methods to hepatic venous pressure gradient in portal hypertension assessment? Journal of gastrointestinal and liver diseases : JGLD 22 (1):73–78PubMed
25.
go back to reference Grieser C, Denecke T, Steffen IG, Avgenaki M, Frohling V, Mogl M et al. (2010) Multidetector computed tomography for preoperative assessment of hepatic vasculature and prediction of splenic artery steal syndrome in patients with liver cirrhosis before transplantation. European radiology 20 (1):108–117. https://doi.org/10.1007/s00330-009-1535-yCrossRefPubMed Grieser C, Denecke T, Steffen IG, Avgenaki M, Frohling V, Mogl M et al. (2010) Multidetector computed tomography for preoperative assessment of hepatic vasculature and prediction of splenic artery steal syndrome in patients with liver cirrhosis before transplantation. European radiology 20 (1):108–117. https://​doi.​org/​10.​1007/​s00330-009-1535-yCrossRefPubMed
26.
go back to reference Grieser C, Steffen IG, Grajewski L, Stelter L, Streitparth F, Schnapauff D et al. (2010) Preoperative multidetector row computed tomography for evaluation and assessment of resection criteria in patients with pancreatic masses. Acta radiologica (Stockholm, Sweden : 1987) 51 (10):1067–1077. https://doi.org/10.3109/02841851.2010.520023 Grieser C, Steffen IG, Grajewski L, Stelter L, Streitparth F, Schnapauff D et al. (2010) Preoperative multidetector row computed tomography for evaluation and assessment of resection criteria in patients with pancreatic masses. Acta radiologica (Stockholm, Sweden : 1987) 51 (10):1067–1077. https://​doi.​org/​10.​3109/​02841851.​2010.​520023
31.
32.
Metadata
Title
Portosystemic shunt surgery in the era of TIPS: imaging-based planning of the surgical approach
Authors
Uli Fehrenbach
Safak Gül-Klein
Miguel de Sousa Mendes
Ingo Steffen
Julienne Stern
Dominik Geisel
Gero Puhl
Timm Denecke
Publication date
01-09-2020
Publisher
Springer US
Published in
Abdominal Radiology / Issue 9/2020
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02599-z

Other articles of this Issue 9/2020

Abdominal Radiology 9/2020 Go to the issue