Skip to main content
Top
Published in: Abdominal Radiology 10/2020

01-10-2020 | Esophagography | Hollow Organ GI

Esophagography and chest CT for detection of perforated esophagus: what factors influence accuracy?

Authors: Martha Terrazas, Lauren Marjon, Matthew Geter, Jess Schwartz, William Thompson

Published in: Abdominal Radiology | Issue 10/2020

Login to get access

Abstract

Purpose

To determine: whether the use of both esophagography (EG) and CT is superior to either study alone in the detection of esophageal injuries and perforations.

Methods

Paired CT and EG performed for suspected perforated or injured native esophagus (NAE) or neo-esophagus (NEOE) were retrospectively identified and independently scored for likelihood of perforation with a Likert scale. Official reports were scored with the same scale. Retrospective study and official interpretations were assessed separately for overall diagnostic accuracy, for diagnosis of contained versus free perforation.

Results

110 paired exams performed in 107 patients fulfilled inclusion criteria. Overall, combined CT and EG retrospective study interpretation was greater than EG or CT scans alone. Study EG and combined CT and EG interpretations were less sensitive for contained perforations than for free perforations. Evaluations of NAE and NEOE showed similar sensitivities. Receiver operating characteristic (ROC) curve generated from combined official CT and EG interpretations was superior to ROC from combined retrospective study interpretations.

Conclusions

Combination of EG and CT can improve sensitivity for detecting perforated intrathoracic viscus, but even with combined studies accurate diagnosis of contained perforations is challenging. Superior performance of official reports suggests that concurrent review using both modalities may improve accuracy.
Literature
1.
go back to reference Young CA, Menias CO, Bhalla S, Prasad SR. CT features of esophageal emergencies. Radiographics 2008;28:1541-1553.CrossRef Young CA, Menias CO, Bhalla S, Prasad SR. CT features of esophageal emergencies. Radiographics 2008;28:1541-1553.CrossRef
2.
go back to reference Wu CH, Chen CM, Chen CC, Wong YC, Wang CJ. Esophagography After Pneumomediastinum Without CT Findings of Esophageal Perforation: Is It Necessary? AJR 2013; 201:977–984.CrossRef Wu CH, Chen CM, Chen CC, Wong YC, Wang CJ. Esophagography After Pneumomediastinum Without CT Findings of Esophageal Perforation: Is It Necessary? AJR 2013; 201:977–984.CrossRef
3.
go back to reference Lantos JE, Levine ME, Rubesin SE, Lau CT, MD, Torigian DA, MD, MA. Comparison Between Esophagography and Chest Computed Tomography for Evaluation of Leaks After Esophagectomy and Gastric Pull-through. J Thorac Imaging 2013;28:121–128. Lantos JE, Levine ME, Rubesin SE, Lau CT, MD, Torigian DA, MD, MA. Comparison Between Esophagography and Chest Computed Tomography for Evaluation of Leaks After Esophagectomy and Gastric Pull-through. J Thorac Imaging 2013;28:121–128.
4.
go back to reference Upponi S, Ganeshan A, D’Costa H, Betts M, Maynard N, Bungay H, Slater A. Radiological detection of post-oesophagectomy anastomotic leak - a comparison between multidetector CT and fluoroscopy. Br J Radiol. 2008;81(967):545-8CrossRef Upponi S, Ganeshan A, D’Costa H, Betts M, Maynard N, Bungay H, Slater A. Radiological detection of post-oesophagectomy anastomotic leak - a comparison between multidetector CT and fluoroscopy. Br J Radiol. 2008;81(967):545-8CrossRef
5.
go back to reference Palacio D, Marom EM, Correa A, Betancourt-Cuellar SL, Hofstetter WL. Diagnosing conduit leak after esophagectomy for esophageal cancer by computed tomography leak protocol and standard esophagram: Is old school still the best? Clin Imaging. 2018;51:23-29. Palacio D, Marom EM, Correa A, Betancourt-Cuellar SL, Hofstetter WL. Diagnosing conduit leak after esophagectomy for esophageal cancer by computed tomography leak protocol and standard esophagram: Is old school still the best? Clin Imaging. 2018;51:23-29.
6.
go back to reference Cameron JL, Kieffer RF, Hendrix TR, Mehigan DG, Baker RR. Seective Nonoperative Management of Contained Intrathoracic Esophageal Disruptions. Annual Thoracic Surgery, 1979, 27(5); 404-408.CrossRef Cameron JL, Kieffer RF, Hendrix TR, Mehigan DG, Baker RR. Seective Nonoperative Management of Contained Intrathoracic Esophageal Disruptions. Annual Thoracic Surgery, 1979, 27(5); 404-408.CrossRef
7.
go back to reference Swanson JO, Levine MS, Redfern RO, Rubesin SE. Usefulness of high-density barium for detection of leaks after esophagogastrectomy, total gastrectomy, and total laryngectomy. AJR Am J Roentgenol. 2003;181(2):415-20.CrossRef Swanson JO, Levine MS, Redfern RO, Rubesin SE. Usefulness of high-density barium for detection of leaks after esophagogastrectomy, total gastrectomy, and total laryngectomy. AJR Am J Roentgenol. 2003;181(2):415-20.CrossRef
8.
go back to reference Hayen A, Macaskill P, Irwig L, Bossuyt P. Appropriate statistical methods are required to assess diagnostic tests for replacement, add-on, and triage. Journal of Clinical Epidemiology 63 (2010) 883-891CrossRef Hayen A, Macaskill P, Irwig L, Bossuyt P. Appropriate statistical methods are required to assess diagnostic tests for replacement, add-on, and triage. Journal of Clinical Epidemiology 63 (2010) 883-891CrossRef
9.
go back to reference Obuchowski NA, Receiver Operating Characteristic Curves and Their Use in Radiology. Radiology 2003; 229:3–8.CrossRef Obuchowski NA, Receiver Operating Characteristic Curves and Their Use in Radiology. Radiology 2003; 229:3–8.CrossRef
10.
go back to reference Rickards G, Magee C, Artino AR. You Can’t Fix by Analysis What You’ve Spoiled by Design: Developing Survey Instruments and Collecting Validity Evidence J Grad Med Educ. 2012; 4(4): 407–410PubMed Rickards G, Magee C, Artino AR. You Can’t Fix by Analysis What You’ve Spoiled by Design: Developing Survey Instruments and Collecting Validity Evidence J Grad Med Educ. 2012; 4(4): 407–410PubMed
11.
go back to reference Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology. 1983;148(3):839-43.CrossRef Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology. 1983;148(3):839-43.CrossRef
12.
go back to reference Kim TJ, Lee KH, Kim YH, Sung WH et al. Postoperative Imaging of Esophageal Cancer :What chest radiologists need to know. RadioGraphics 2007;27:409-429.CrossRef Kim TJ, Lee KH, Kim YH, Sung WH et al. Postoperative Imaging of Esophageal Cancer :What chest radiologists need to know. RadioGraphics 2007;27:409-429.CrossRef
13.
go back to reference Flanagan JC, Batz R,Saboo SS, Nordeck SM, Abbara S, Kernstine K, Vasan V. Esophagectomy and Gastric Pull-through Procedures: Surgical Techniques, Imaging Features, and Potential Complications. RadioGraphics, 2016, Vol. 36: 107–121.CrossRef Flanagan JC, Batz R,Saboo SS, Nordeck SM, Abbara S, Kernstine K, Vasan V. Esophagectomy and Gastric Pull-through Procedures: Surgical Techniques, Imaging Features, and Potential Complications. RadioGraphics, 2016, Vol. 36: 107–121.CrossRef
14.
go back to reference Madan R, Laur O, MD, Crudup B, Peavy P, Carter BW. Imaging of iatrogenic oesophageal injuries usingoptimized CT oesophageal leak protocol: pearls and pitfalls. Br J Radiol 2017; 90: 20170629. Madan R, Laur O, MD, Crudup B, Peavy P, Carter BW. Imaging of iatrogenic oesophageal injuries usingoptimized CT oesophageal leak protocol: pearls and pitfalls. Br J Radiol 2017; 90: 20170629.
15.
go back to reference Suarez-Poveda T, Morales-Uribe C H, Sanabria A, Llano-Sánchez A, Valencia-Delgado AM et al. Diagnostic performance of CT esophagography in patients with suspected esophageal rupture. Emerg Radiol (2014) 21:505–510.CrossRef Suarez-Poveda T, Morales-Uribe C H, Sanabria A, Llano-Sánchez A, Valencia-Delgado AM et al. Diagnostic performance of CT esophagography in patients with suspected esophageal rupture. Emerg Radiol (2014) 21:505–510.CrossRef
16.
go back to reference Fadoo F, Ruiz DE, Dawn SK, Webb WR, Gotway MB. Helical CT esophagography for the evaluation of suspected esophageal perforation or rupture. AJR;182:1177-1179.CrossRef Fadoo F, Ruiz DE, Dawn SK, Webb WR, Gotway MB. Helical CT esophagography for the evaluation of suspected esophageal perforation or rupture. AJR;182:1177-1179.CrossRef
17.
go back to reference Ho AS, Ahmed A, S. Huang JS, MD, Menias CO, MD, Bhalla S. Multidetector Computed Tomography of Spontaneous Versus Secondary Pneumomediastinum in 89 Patients Can Multidetector Computed Tomography be Used to Reliably Distinguish Between the 2 Entities? J Thorac Imaging 2012;27:85–92. Ho AS, Ahmed A, S. Huang JS, MD, Menias CO, MD, Bhalla S. Multidetector Computed Tomography of Spontaneous Versus Secondary Pneumomediastinum in 89 Patients Can Multidetector Computed Tomography be Used to Reliably Distinguish Between the 2 Entities? J Thorac Imaging 2012;27:85–92.
18.
go back to reference Sakai M1, Murayama S, Gibo M, Akamine T, Nagata O. Frequent cause of the Macklin effect in spontaneous pneumomediastinum: demonstration by multidetector-row computed tomography. J Comput Assist Tomogr. 2006;30(1):92-4. Sakai M1, Murayama S, Gibo M, Akamine T, Nagata O. Frequent cause of the Macklin effect in spontaneous pneumomediastinum: demonstration by multidetector-row computed tomography. J Comput Assist Tomogr. 2006;30(1):92-4.
Metadata
Title
Esophagography and chest CT for detection of perforated esophagus: what factors influence accuracy?
Authors
Martha Terrazas
Lauren Marjon
Matthew Geter
Jess Schwartz
William Thompson
Publication date
01-10-2020
Publisher
Springer US
Keyword
Esophagography
Published in
Abdominal Radiology / Issue 10/2020
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-02187-w

Other articles of this Issue 10/2020

Abdominal Radiology 10/2020 Go to the issue