Skip to main content
Top
Published in: Abdominal Radiology 6/2019

01-06-2019 | Insulinoma | Pancreas

Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters

Authors: Ping Li, Wanling Deng, Huadan Xue, Kai Xu, Liang Zhu, Juan Li, Zhaoyong Sun, Zhengyu Jin

Published in: Abdominal Radiology | Issue 6/2019

Login to get access

Abstract

Purpose

We evaluate the reliability and feasibility of weight-adapted ultra-low-dose pancreatic perfusion CT.

Methods

A total of 100 (47 men, 53 women) patients were enrolled prospectively and were assigned to five groups (A, B, C, D, and E) with different combination of tube voltage and tube current according to their body weight. Radiation dose parameters including volume CT dose index (CTDI) and dose-length product (DLP) were recorded. Image quality was evaluated both subjectively and objectively (noise, signal-to-noise ratio, contrast-to-noise ratio). Perfusion parameters including blood flow (BF), blood volume (BV), and permeability (PMB) were measured. The dose, image quality measurements, and perfusion parameters were compared between the five groups using one-way analysis of variance (ANOVA).

Results

Radiation dose reached 8.7 mSv in patients under 50 kg and was 18.9 mSv in patients above 80 kg. The mean subjective image quality score was above 4.45 on a 5-point scale with good agreement between two radiologists. Groups A–D had equivalent performance on objective image quality (P > 0.05), while Group E performed even better (P < 0.05). No significant differences emerged in comparison with perfusion parameters (BF, BV, PMB) of normal pancreas parenchyma between the five groups.

Conclusion

Weight-adapted ultra-low-dose pancreatic perfusion CT can effectively reduce radiation dose without prejudice to image quality, and the perfusion parameters of normal parenchyma are accurate and reliable.
Literature
11.
go back to reference Zhu L, Xue H, Sun Z, Li P, Qian T, Xing X, Li N, Zhao Y, Wu W, Jin Z (2017) Prospective comparison of biphasic contrast-enhanced CT, volume perfusion CT, and 3 Tesla MRI with diffusion-weighted imaging for insulinoma detection. Journal of magnetic resonance imaging : JMRI 46 (6):1648-1655. https://doi.org/10.1002/jmri.25709 CrossRefPubMed Zhu L, Xue H, Sun Z, Li P, Qian T, Xing X, Li N, Zhao Y, Wu W, Jin Z (2017) Prospective comparison of biphasic contrast-enhanced CT, volume perfusion CT, and 3 Tesla MRI with diffusion-weighted imaging for insulinoma detection. Journal of magnetic resonance imaging : JMRI 46 (6):1648-1655. https://​doi.​org/​10.​1002/​jmri.​25709 CrossRefPubMed
12.
go back to reference Tsuji Y, Hamaguchi K, Watanabe Y, Okumura A, Isoda H, Yamamoto N, Kikuchi O, Yamamoto H, Matsueda K, Ueno K, Tada S, Togashi K, Yamamoto H, Chiba T (2010) Perfusion CT is superior to angiography in predicting pancreatic necrosis in patients with severe acute pancreatitis. Journal of gastroenterology 45 (11):1155-1162. https://doi.org/10.1007/s00535-010-0267-8 CrossRefPubMed Tsuji Y, Hamaguchi K, Watanabe Y, Okumura A, Isoda H, Yamamoto N, Kikuchi O, Yamamoto H, Matsueda K, Ueno K, Tada S, Togashi K, Yamamoto H, Chiba T (2010) Perfusion CT is superior to angiography in predicting pancreatic necrosis in patients with severe acute pancreatitis. Journal of gastroenterology 45 (11):1155-1162. https://​doi.​org/​10.​1007/​s00535-010-0267-8 CrossRefPubMed
14.
go back to reference Tsuji Y, Yamamoto H, Yazumi S, Watanabe Y, Matsueda K, Yamamoto H, Chiba T (2007) Perfusion computerized tomography can predict pancreatic necrosis in early stages of severe acute pancreatitis. Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 5 (12):1484-1492. https://doi.org/10.1016/j.cgh.2007.07.014 CrossRef Tsuji Y, Yamamoto H, Yazumi S, Watanabe Y, Matsueda K, Yamamoto H, Chiba T (2007) Perfusion computerized tomography can predict pancreatic necrosis in early stages of severe acute pancreatitis. Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 5 (12):1484-1492. https://​doi.​org/​10.​1016/​j.​cgh.​2007.​07.​014 CrossRef
15.
go back to reference Yadav AK, Sharma R, Kandasamy D, Pradhan RK, Garg PK, Bhalla AS, Gamanagatti S, Srivastava DN, Sahni P, Upadhyay AD (2016) Perfusion CT - Can it resolve the pancreatic carcinoma versus mass forming chronic pancreatitis conundrum? Pancreatology : official journal of the International Association of Pancreatology (IAP) [et al] 16 (6):979-987. https://doi.org/10.1016/j.pan.2016.08.011 Yadav AK, Sharma R, Kandasamy D, Pradhan RK, Garg PK, Bhalla AS, Gamanagatti S, Srivastava DN, Sahni P, Upadhyay AD (2016) Perfusion CT - Can it resolve the pancreatic carcinoma versus mass forming chronic pancreatitis conundrum? Pancreatology : official journal of the International Association of Pancreatology (IAP) [et al] 16 (6):979-987. https://​doi.​org/​10.​1016/​j.​pan.​2016.​08.​011
16.
go back to reference Wang X, Henzler T, Gawlitza J, Diehl S, Wilhelm T, Schoenberg SO, Jin ZY, Xue HD, Smakic A (2016) Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer. Eur J Radiol 85 (11):2104-2110. https://doi.org/10.1016/j.ejrad.2016.09.024 CrossRefPubMed Wang X, Henzler T, Gawlitza J, Diehl S, Wilhelm T, Schoenberg SO, Jin ZY, Xue HD, Smakic A (2016) Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer. Eur J Radiol 85 (11):2104-2110. https://​doi.​org/​10.​1016/​j.​ejrad.​2016.​09.​024 CrossRefPubMed
17.
go back to reference Gordic S, Morsbach F, Schmidt B, Allmendinger T, Flohr T, Husarik D, Baumueller S, Raupach R, Stolzmann P, Leschka S, Frauenfelder T, Alkadhi H (2014) Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping. Investigative radiology 49 (7):465-473. https://doi.org/10.1097/RLI.0000000000000037 CrossRefPubMed Gordic S, Morsbach F, Schmidt B, Allmendinger T, Flohr T, Husarik D, Baumueller S, Raupach R, Stolzmann P, Leschka S, Frauenfelder T, Alkadhi H (2014) Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping. Investigative radiology 49 (7):465-473. https://​doi.​org/​10.​1097/​RLI.​0000000000000037​ CrossRefPubMed
19.
go back to reference Tesche C, De Cecco CN, Vliegenthart R, Albrecht MH, Varga-Szemes A, Duguay TM, Ebersberger U, Bayer RR, 2nd, Canstein C, Schmidt B, Allmendinger T, Litwin SE, Morris PB, Flohr TG, Hoffmann E, Schoepf UJ (2017) Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration. Am J Cardiol 119 (4):675-680. https://doi.org/10.1016/j.amjcard.2016.10.051 CrossRefPubMed Tesche C, De Cecco CN, Vliegenthart R, Albrecht MH, Varga-Szemes A, Duguay TM, Ebersberger U, Bayer RR, 2nd, Canstein C, Schmidt B, Allmendinger T, Litwin SE, Morris PB, Flohr TG, Hoffmann E, Schoepf UJ (2017) Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration. Am J Cardiol 119 (4):675-680. https://​doi.​org/​10.​1016/​j.​amjcard.​2016.​10.​051 CrossRefPubMed
21.
go back to reference Apfaltrer G, Albrecht MH, Schoepf UJ, Duguay TM, De Cecco CN, Nance JW, De Santis D, Apfaltrer P, Eid MH, Eason CD, Thompson ZM, Bauer MJ, Varga-Szemes A, Jacobs BE, Sorantin E, Tesche C (2018) High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction. European radiology 28 (7):3097-3104. https://doi.org/10.1007/s00330-017-5249-2 CrossRefPubMed Apfaltrer G, Albrecht MH, Schoepf UJ, Duguay TM, De Cecco CN, Nance JW, De Santis D, Apfaltrer P, Eid MH, Eason CD, Thompson ZM, Bauer MJ, Varga-Szemes A, Jacobs BE, Sorantin E, Tesche C (2018) High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction. European radiology 28 (7):3097-3104. https://​doi.​org/​10.​1007/​s00330-017-5249-2 CrossRefPubMed
22.
go back to reference Stacul F, van der Molen AJ, Reimer P, Webb JA, Thomsen HS, Morcos SK, Almen T, Aspelin P, Bellin MF, Clement O, Heinz-Peer G, Contrast Media Safety Committee of European Society of Urogenital R (2011) Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines. European radiology 21 (12):2527-2541. https://doi.org/10.1007/s00330-011-2225-0 CrossRef Stacul F, van der Molen AJ, Reimer P, Webb JA, Thomsen HS, Morcos SK, Almen T, Aspelin P, Bellin MF, Clement O, Heinz-Peer G, Contrast Media Safety Committee of European Society of Urogenital R (2011) Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines. European radiology 21 (12):2527-2541. https://​doi.​org/​10.​1007/​s00330-011-2225-0 CrossRef
29.
go back to reference Miles KA, Lee TY, Goh V, Klotz E, Cuenod C, Bisdas S, Groves AM, Hayball MP, Alonzi R, Brunner T, Experimental Cancer Medicine Centre Imaging Network G (2012) Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography. European radiology 22 (7):1430-1441. https://doi.org/10.1007/s00330-012-2379-4 CrossRefPubMed Miles KA, Lee TY, Goh V, Klotz E, Cuenod C, Bisdas S, Groves AM, Hayball MP, Alonzi R, Brunner T, Experimental Cancer Medicine Centre Imaging Network G (2012) Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography. European radiology 22 (7):1430-1441. https://​doi.​org/​10.​1007/​s00330-012-2379-4 CrossRefPubMed
38.
40.
go back to reference Xue HD, Jin ZY, Liu W, Wang Y, Zhao WM (2006) [Perfusion characteristics of normal pancreas and insulinoma on multi-slice spiral CT]. Zhongguo yi xue ke xue yuan xue bao Acta Academiae Medicinae Sinicae 28 (1):68-70.PubMed Xue HD, Jin ZY, Liu W, Wang Y, Zhao WM (2006) [Perfusion characteristics of normal pancreas and insulinoma on multi-slice spiral CT]. Zhongguo yi xue ke xue yuan xue bao Acta Academiae Medicinae Sinicae 28 (1):68-70.PubMed
Metadata
Title
Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters
Authors
Ping Li
Wanling Deng
Huadan Xue
Kai Xu
Liang Zhu
Juan Li
Zhaoyong Sun
Zhengyu Jin
Publication date
01-06-2019
Publisher
Springer US
Published in
Abdominal Radiology / Issue 6/2019
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-01938-z

Other articles of this Issue 6/2019

Abdominal Radiology 6/2019 Go to the issue

Classics in Abdominal Radiology

Teardrop sign