Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Authors: Kathryn E. Darras, Sheldon J. Clark, Heejun Kang, Mohammed F. Mohammed, Sarah Barrett, Silvia D. Chang, Alison C. Harris, Savvas Nicolaou, Patrick D. McLaughlin

Published in: Abdominal Radiology | Issue 2/2019

Login to get access

Abstract

Purpose

To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset.

Materials and methods

Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence.

Results

The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001).

Conclusion

VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.
Literature
1.
go back to reference Levy AD, Shaw JC, Sobin LH (2009) Secondary tumors and tumorlike lesions of the peritoneal cavity: imaging features with pathologic correlation. Radiographics 29(2):347–373CrossRefPubMed Levy AD, Shaw JC, Sobin LH (2009) Secondary tumors and tumorlike lesions of the peritoneal cavity: imaging features with pathologic correlation. Radiographics 29(2):347–373CrossRefPubMed
2.
go back to reference O’Dwyer S, Verwaal VJ, Sugarbaker PH (2015) Evolution of treatments for peritoneal metastases from colorectal cancer. J Clin Oncol 33(18):2122–2123CrossRefPubMed O’Dwyer S, Verwaal VJ, Sugarbaker PH (2015) Evolution of treatments for peritoneal metastases from colorectal cancer. J Clin Oncol 33(18):2122–2123CrossRefPubMed
3.
go back to reference Klaver CEL, et al. (2015) Adjuvant hyperthermic intraperitoneal chemotherapy (HIPEC) in patients with colon cancer at high risk of peritoneal carcinomatosis; the COLOPEC randomized multicentre trial. BMC Cancer 15:428CrossRefPubMedPubMedCentral Klaver CEL, et al. (2015) Adjuvant hyperthermic intraperitoneal chemotherapy (HIPEC) in patients with colon cancer at high risk of peritoneal carcinomatosis; the COLOPEC randomized multicentre trial. BMC Cancer 15:428CrossRefPubMedPubMedCentral
4.
go back to reference Naffouje SA, Salti GI (2018) Cytoreductive surgery and hyperthermic intraperitoneal chemotherapy in elderly patients: complete cytoreduction is feasible and crucial for improved survival despite high carcinomatosis index. Anticancer Res 38(1):441–448PubMed Naffouje SA, Salti GI (2018) Cytoreductive surgery and hyperthermic intraperitoneal chemotherapy in elderly patients: complete cytoreduction is feasible and crucial for improved survival despite high carcinomatosis index. Anticancer Res 38(1):441–448PubMed
5.
go back to reference Huang Y, Alzahrani NA, Liauw W, et al. (2017) Early postoperative intraperitoneal chemotherapy is associated with survival benefit for appendiceal adenocarcinoma with peritoneal dissemination. Eur J Surg Oncol 43(12):2292–2298CrossRefPubMed Huang Y, Alzahrani NA, Liauw W, et al. (2017) Early postoperative intraperitoneal chemotherapy is associated with survival benefit for appendiceal adenocarcinoma with peritoneal dissemination. Eur J Surg Oncol 43(12):2292–2298CrossRefPubMed
6.
go back to reference Magge D, et al. (2017) Hyperthermic intraperitoneal chemoperfusion as a component of multimodality therapy for ovarian and primary peritoneal cancer. J Surg Oncol 116(3):320–328CrossRefPubMedPubMedCentral Magge D, et al. (2017) Hyperthermic intraperitoneal chemoperfusion as a component of multimodality therapy for ovarian and primary peritoneal cancer. J Surg Oncol 116(3):320–328CrossRefPubMedPubMedCentral
7.
go back to reference Grabowska-Derlatka L, Derlatka P, Szeszkowski W, Cieszanowski A (2016) Diffusion-weighted imaging of small peritoneal implants in ‘potentially’ early-stage ovarian cancer. Biomed Res Int 2016:9254742CrossRefPubMedPubMedCentral Grabowska-Derlatka L, Derlatka P, Szeszkowski W, Cieszanowski A (2016) Diffusion-weighted imaging of small peritoneal implants in ‘potentially’ early-stage ovarian cancer. Biomed Res Int 2016:9254742CrossRefPubMedPubMedCentral
8.
go back to reference Fehniger J, et al. (2016) A prospective study evaluating diffusion weighted magnetic resonance imaging (DW-MRI) in the detection of peritoneal carcinomatosis in suspected gynecologic malignancies. Gynecol Oncol 142(1):169–175CrossRefPubMed Fehniger J, et al. (2016) A prospective study evaluating diffusion weighted magnetic resonance imaging (DW-MRI) in the detection of peritoneal carcinomatosis in suspected gynecologic malignancies. Gynecol Oncol 142(1):169–175CrossRefPubMed
9.
go back to reference Chen F-M, Ni J-M, Zhang Z-Y, et al. (2016) Presurgical evaluation of pancreatic cancer: a comprehensive imaging comparison of CT versus MRI. AJR Am J Roentgenol 206(3):526–535CrossRefPubMed Chen F-M, Ni J-M, Zhang Z-Y, et al. (2016) Presurgical evaluation of pancreatic cancer: a comprehensive imaging comparison of CT versus MRI. AJR Am J Roentgenol 206(3):526–535CrossRefPubMed
10.
go back to reference Schmidt S, Meuli RA, Achtari C, Prior JO (2015) Peritoneal carcinomatosis in primary ovarian cancer staging: comparison between MDCT, MRI, and 18F-FDG PET/CT. Clin Nucl Med 40(5):371–377CrossRefPubMed Schmidt S, Meuli RA, Achtari C, Prior JO (2015) Peritoneal carcinomatosis in primary ovarian cancer staging: comparison between MDCT, MRI, and 18F-FDG PET/CT. Clin Nucl Med 40(5):371–377CrossRefPubMed
11.
go back to reference Marin D, et al. (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm–initial clinical experience. Radiology 254(1):145–153CrossRefPubMed Marin D, et al. (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm–initial clinical experience. Radiology 254(1):145–153CrossRefPubMed
12.
go back to reference Silva AC, Morse BG, Hara AK, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics 31(4):1031–1050CrossRefPubMed Silva AC, Morse BG, Hara AK, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics 31(4):1031–1050CrossRefPubMed
13.
go back to reference Yu L, Christner JA, Leng S, et al. (2011) Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 38(12):6371–6379CrossRefPubMedPubMedCentral Yu L, Christner JA, Leng S, et al. (2011) Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 38(12):6371–6379CrossRefPubMedPubMedCentral
14.
go back to reference Yu L, Leng S, McCollough CH (2012) Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol 199(5 Suppl):S9–S15CrossRefPubMed Yu L, Leng S, McCollough CH (2012) Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol 199(5 Suppl):S9–S15CrossRefPubMed
15.
go back to reference Srinivasan A, Parker RA, Manjunathan A, et al. (2013) Differentiation of benign and malignant neck pathologies: preliminary experience using spectral computed tomography. J Comput Assist Tomogr 37(5):666–672CrossRefPubMed Srinivasan A, Parker RA, Manjunathan A, et al. (2013) Differentiation of benign and malignant neck pathologies: preliminary experience using spectral computed tomography. J Comput Assist Tomogr 37(5):666–672CrossRefPubMed
16.
go back to reference Shuman WP, et al. (2014) Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. AJR Am J Roentgenol 203(3):601–606CrossRefPubMed Shuman WP, et al. (2014) Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. AJR Am J Roentgenol 203(3):601–606CrossRefPubMed
17.
go back to reference Wang Q, Shi G, Qi X, Fan X, Wang L (2014) Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization. Eur J Radiol 83(10):1759–1764CrossRefPubMed Wang Q, Shi G, Qi X, Fan X, Wang L (2014) Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization. Eur J Radiol 83(10):1759–1764CrossRefPubMed
18.
go back to reference Hou WS, Wu HW, Yin Y, et al. (2015) Differentiation of lung cancers from inflammatory masses with dual-energy spectral CT imaging. Acad Radiol 22(3):337–344CrossRefPubMed Hou WS, Wu HW, Yin Y, et al. (2015) Differentiation of lung cancers from inflammatory masses with dual-energy spectral CT imaging. Acad Radiol 22(3):337–344CrossRefPubMed
19.
go back to reference Yuan Y, Zhang Y, Lang N, Li J, Yuan H (2015) Differentiating malignant vertebral tumours from non-malignancies with CT spectral imaging: a preliminary study. Eur Radiol 25(10):2945–2950CrossRefPubMed Yuan Y, Zhang Y, Lang N, Li J, Yuan H (2015) Differentiating malignant vertebral tumours from non-malignancies with CT spectral imaging: a preliminary study. Eur Radiol 25(10):2945–2950CrossRefPubMed
21.
go back to reference Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning. Am J Roentgenol 194(4):881–889CrossRef Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning. Am J Roentgenol 194(4):881–889CrossRef
22.
go back to reference Bongartz G et al. (1999) European guidelines on quality criteria for computed tomography. Eur Comm. Bongartz G et al. (1999) European guidelines on quality criteria for computed tomography. Eur Comm.
23.
go back to reference Fu W, et al. (2017) Optimizing window settings for improved presentation of virtual monoenergetic images in dual-energy computed tomography. Med Phys 44(11):5686–5696CrossRefPubMed Fu W, et al. (2017) Optimizing window settings for improved presentation of virtual monoenergetic images in dual-energy computed tomography. Med Phys 44(11):5686–5696CrossRefPubMed
25.
go back to reference Morgan DE (2018) The role of dual-energy computed tomography in assessment of abdominal oncology and beyond. Radiol Clin North Am 56(4):565–585CrossRefPubMed Morgan DE (2018) The role of dual-energy computed tomography in assessment of abdominal oncology and beyond. Radiol Clin North Am 56(4):565–585CrossRefPubMed
26.
go back to reference McNamara MM, Little MD, Alexander LF, et al. (2015) Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT. Abdom Imaging 40(5):1230–1240CrossRefPubMed McNamara MM, Little MD, Alexander LF, et al. (2015) Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT. Abdom Imaging 40(5):1230–1240CrossRefPubMed
27.
go back to reference Sodickson A, Primak A, Keraliya A. Workflow evaluation of a new fully automated dual-energy CT post-processing configuration. In: Radiological Society of North America (RSNA) Scientific Assembly and Annual Meeting Sodickson A, Primak A, Keraliya A. Workflow evaluation of a new fully automated dual-energy CT post-processing configuration. In: Radiological Society of North America (RSNA) Scientific Assembly and Annual Meeting
Metadata
Title
Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits
Authors
Kathryn E. Darras
Sheldon J. Clark
Heejun Kang
Mohammed F. Mohammed
Sarah Barrett
Silvia D. Chang
Alison C. Harris
Savvas Nicolaou
Patrick D. McLaughlin
Publication date
01-02-2019
Publisher
Springer US
Published in
Abdominal Radiology / Issue 2/2019
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-018-1733-7

Other articles of this Issue 2/2019

Abdominal Radiology 2/2019 Go to the issue