Skip to main content
Top
Published in: Abdominal Radiology 11/2018

01-11-2018

Dual-layer spectral detector CT: non-inferiority assessment compared to dual-source dual-energy CT in discriminating uric acid from non-uric acid renal stones ex vivo

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Yin Xi, Matthew A. Lewis, Margaret S. Pearle, Jodi A. Antonelli, Harold Goerne, Elysha M. Kolitz, Suhny Abbara, Robert E. Lenkinski, Julia R. Fielding, John R. Leyendecker

Published in: Abdominal Radiology | Issue 11/2018

Login to get access

Abstract

Purpose

To assess the non-inferiority of dual-layer spectral detector CT (SDCT) compared to dual-source dual-energy CT (dsDECT) in discriminating uric acid (UA) from non-UA stones.

Methods

Fifty-seven extracted urinary calculi were placed in a cylindrical phantom in a water bath and scanned on a SDCT scanner (IQon, Philips Healthcare) and second- and third-generation dsDECT scanners (Somatom Flash and Force, Siemens Healthcare) under matched scan parameters. For SDCT data, conventional images and virtual monoenergetic reconstructions were created. A customized 3D growing region segmentation tool was used to segment each stone on a pixel-by-pixel basis for statistical analysis. Median virtual monoenergetic ratios (VMRs) of 40/200, 62/92, and 62/100 for each stone were recorded. For dsDECT data, dual-energy ratio (DER) for each stone was recorded from vendor-specific postprocessing software (Syngo Via) using the Kidney Stones Application. The clinical reference standard of X-ray diffraction analysis was used to assess non-inferiority. Area under the receiver-operating characteristic curve (AUC) was used to assess diagnostic performance of detecting UA stones.

Results

Six pure UA, 47 pure calcium-based, 1 pure cystine, and 3 mixed struvite stones were scanned. All pure UA stones were correctly separated from non-UA stones using SDCT and dsDECT (AUC = 1). For UA stones, median VMR was 0.95–0.99 and DER 1.00–1.02. For non-UA stones, median VMR was 1.4–4.1 and DER 1.39–1.69.

Conclusion

SDCT spectral reconstructions demonstrate similar performance to those of dsDECT in discriminating UA from non-UA stones in a phantom model.
Literature
1.
go back to reference Scales CD Jr, Smith AC, Hanley JM, Saigal CS (2012) Prevalence of kidney stones in the United States. Eur Urol 62:160–165CrossRef Scales CD Jr, Smith AC, Hanley JM, Saigal CS (2012) Prevalence of kidney stones in the United States. Eur Urol 62:160–165CrossRef
2.
go back to reference Uribarri J, Oh MS, Carroll HJ (1989) The first kidney stone. Ann Intern Med 111:1006–1009CrossRef Uribarri J, Oh MS, Carroll HJ (1989) The first kidney stone. Ann Intern Med 111:1006–1009CrossRef
3.
go back to reference Morgan MS, Pearle MS (2016) Medical management of renal stones. BMJ (Clinical research ed) 352:i52 Morgan MS, Pearle MS (2016) Medical management of renal stones. BMJ (Clinical research ed) 352:i52
4.
go back to reference Newhouse JH, Prien EL, Amis ES Jr, Dretler SP, Pfister RC (1984) Computed tomographic analysis of urinary calculi. AJR Am J Roentgenol 142:545–548CrossRef Newhouse JH, Prien EL, Amis ES Jr, Dretler SP, Pfister RC (1984) Computed tomographic analysis of urinary calculi. AJR Am J Roentgenol 142:545–548CrossRef
5.
go back to reference Motley G, Dalrymple N, Keesling C, Fischer J, Harmon W (2001) Hounsfield unit density in the determination of urinary stone composition. Urology 58:170–173CrossRef Motley G, Dalrymple N, Keesling C, Fischer J, Harmon W (2001) Hounsfield unit density in the determination of urinary stone composition. Urology 58:170–173CrossRef
6.
go back to reference Graser A, Johnson TR, Bader M, et al. (2008) Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol 43:112–119CrossRef Graser A, Johnson TR, Bader M, et al. (2008) Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol 43:112–119CrossRef
7.
go back to reference Boll DT, Patil NA, Paulson EK, et al. (2009) Renal stone assessment with dual-energy multidetector CT and advanced postprocessing techniques: improved characterization of renal stone composition–pilot study. Radiology 250:813–820CrossRef Boll DT, Patil NA, Paulson EK, et al. (2009) Renal stone assessment with dual-energy multidetector CT and advanced postprocessing techniques: improved characterization of renal stone composition–pilot study. Radiology 250:813–820CrossRef
8.
go back to reference Duan X, Li Z, Yu L, et al. (2015) Characterization of urinary stone composition by use of third-generation dual-source dual-energy CT with increased spectral separation. AJR Am J Roentgenol 205:1203–1207CrossRef Duan X, Li Z, Yu L, et al. (2015) Characterization of urinary stone composition by use of third-generation dual-source dual-energy CT with increased spectral separation. AJR Am J Roentgenol 205:1203–1207CrossRef
9.
go back to reference Kulkarni NM, Eisner BH, Pinho DF, et al. (2013) Determination of renal stone composition in phantom and patients using single-source dual-energy computed tomography. J Comput Assist Tomogr 37:37–45CrossRef Kulkarni NM, Eisner BH, Pinho DF, et al. (2013) Determination of renal stone composition in phantom and patients using single-source dual-energy computed tomography. J Comput Assist Tomogr 37:37–45CrossRef
10.
go back to reference Ananthakrishnan L, Rajiah P, Ahn R, et al. (2017) Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT. Abdom Radiol (NY) 42(3):702–709CrossRef Ananthakrishnan L, Rajiah P, Ahn R, et al. (2017) Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT. Abdom Radiol (NY) 42(3):702–709CrossRef
11.
go back to reference Blackledge MD, Collins DJ, Koh DM, Leach MO (2016) Rapid development of image analysis research tools: bridging the gap between researcher and clinician with pyOsiriX. Comput Biol Med 69:203–212CrossRef Blackledge MD, Collins DJ, Koh DM, Leach MO (2016) Rapid development of image analysis research tools: bridging the gap between researcher and clinician with pyOsiriX. Comput Biol Med 69:203–212CrossRef
12.
go back to reference McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653CrossRef McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653CrossRef
13.
go back to reference Lombardo F, Bonatti M, Zamboni GA, et al. (2017) Uric acid versus non-uric acid renal stones: in vivo differentiation with spectral CT. Clin Radiol 72:490–496CrossRef Lombardo F, Bonatti M, Zamboni GA, et al. (2017) Uric acid versus non-uric acid renal stones: in vivo differentiation with spectral CT. Clin Radiol 72:490–496CrossRef
14.
go back to reference Hidas G, Eliahou R, Duvdevani M, et al. (2010) Determination of renal stone composition with dual-energy CT: in vivo analysis and comparison with x-ray diffraction. Radiology 257:394–401CrossRef Hidas G, Eliahou R, Duvdevani M, et al. (2010) Determination of renal stone composition with dual-energy CT: in vivo analysis and comparison with x-ray diffraction. Radiology 257:394–401CrossRef
15.
go back to reference Siener R, Buchholz N, Daudon M, et al. (2016) quality assessment of urinary stone analysis: results of a multicenter study of laboratories in Europe. PloS ONE 11:e0156606CrossRef Siener R, Buchholz N, Daudon M, et al. (2016) quality assessment of urinary stone analysis: results of a multicenter study of laboratories in Europe. PloS ONE 11:e0156606CrossRef
Metadata
Title
Dual-layer spectral detector CT: non-inferiority assessment compared to dual-source dual-energy CT in discriminating uric acid from non-uric acid renal stones ex vivo
Authors
Lakshmi Ananthakrishnan
Xinhui Duan
Yin Xi
Matthew A. Lewis
Margaret S. Pearle
Jodi A. Antonelli
Harold Goerne
Elysha M. Kolitz
Suhny Abbara
Robert E. Lenkinski
Julia R. Fielding
John R. Leyendecker
Publication date
01-11-2018
Publisher
Springer US
Published in
Abdominal Radiology / Issue 11/2018
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-018-1589-x

Other articles of this Issue 11/2018

Abdominal Radiology 11/2018 Go to the issue
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.