Abstract

Purpose

To determine whether the use of a low-dose acquisition protocol (LDP) in digital subtraction angiography during transjugular intrahepatic portosystemic shunt (TIPS) creation/revision results in significant reduction of patient radiation exposure and adequate image quality, as compared to a default reference standard-dose acquisition protocol (SDP).

Methods

Two angiographic runs were performed during TIPS creation/revision: the first following catheterization of the portal venous system and the second after stent deployment/angioplasty. Constant field of view, object to image-detector distance, and source to image-receptor distance were maintained in each patient during the two angiographic runs. 17 consecutive adult patients who underwent TIPS creation (n = 11) or TIPS revision (n = 6) from December 2013 to March 2014 were considered eligible for this single centre prospective study. In each patient, the LDP and the SDP were used in a random order for the two runs, with each patient serving as his/her own control. The dose-area product (DAP) was calculated for each image and compared. Image quality was graded by two interventional radiologists other than the operator.

Results

In all runs acquired with the LDP, image quality was considered adequate for a successful procedural outcome. The DAP per image of the LDP was numerically inferior as compared to the DAP per image of the SDP in all patients. The mean reduction in DAP per image was 75.24% ± 5.7% (p < 0. 001).

Conclusion

Radiation exposure during TIPS creation/revision was significantly reduced by selecting a LDP in our flat-panel detector-based system, while maintaining adequate image quality.
Literature
1.
go back to reference Pitton MB, Kloeckner R, Schneider J, et al. (2012) Radiation exposure in vascular angiographic procedures. J Vasc Interv Radiol 23(11):1487–1495PubMedCrossRef Pitton MB, Kloeckner R, Schneider J, et al. (2012) Radiation exposure in vascular angiographic procedures. J Vasc Interv Radiol 23(11):1487–1495PubMedCrossRef
2.
go back to reference Kuon E, Robinson DM, Empen K, Dahm JB (2005) Fluoroscopy time—an overestimated factor for patient radiation exposure in invasive cardiology. Rofo 177:812–817PubMedCrossRef Kuon E, Robinson DM, Empen K, Dahm JB (2005) Fluoroscopy time—an overestimated factor for patient radiation exposure in invasive cardiology. Rofo 177:812–817PubMedCrossRef
3.
go back to reference Miller DL, Balter S, Cole PE, et al. (2003) Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 14(6):711–727PubMedCrossRef Miller DL, Balter S, Cole PE, et al. (2003) Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 14(6):711–727PubMedCrossRef
4.
go back to reference Zweers D, Geleijns J, Aarts NJ, et al. (1998) Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings. Br J Radiol 71(846):672–676PubMedCrossRef Zweers D, Geleijns J, Aarts NJ, et al. (1998) Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings. Br J Radiol 71(846):672–676PubMedCrossRef
5.
go back to reference Garcia-Pagan JC, Heydtmann M, Raffa S, et al. (2008) TIPS for Budd–Chiari syndrome: long-term results and prognostics factors in 124 patients. Gastroenterology 135(3):808–815PubMedCrossRef Garcia-Pagan JC, Heydtmann M, Raffa S, et al. (2008) TIPS for Budd–Chiari syndrome: long-term results and prognostics factors in 124 patients. Gastroenterology 135(3):808–815PubMedCrossRef
6.
go back to reference Tripathi D, Macnicholas R, Kothari C, et al. (2014) Good clinical outcomes following transjugular intrahepatic portosystemic stent-shunts in Budd–Chiari syndrome. Aliment Pharmacol Ther 39(8):864–872PubMedCrossRef Tripathi D, Macnicholas R, Kothari C, et al. (2014) Good clinical outcomes following transjugular intrahepatic portosystemic stent-shunts in Budd–Chiari syndrome. Aliment Pharmacol Ther 39(8):864–872PubMedCrossRef
7.
go back to reference Seijo S, Plessier A, Hoekstra J, et al. (2013) Good long-term outcome of Budd–Chiari syndrome with a step-wise management. Hepatology 57(5):1962–1968PubMedCrossRef Seijo S, Plessier A, Hoekstra J, et al. (2013) Good long-term outcome of Budd–Chiari syndrome with a step-wise management. Hepatology 57(5):1962–1968PubMedCrossRef
8.
go back to reference Di Giorgio A, Agazzi R, Alberti D, Colledan M, D’Antiga L (2012) Feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in children. J Pediatr Gastroenterol Nutr 54(5):594–600PubMedCrossRef Di Giorgio A, Agazzi R, Alberti D, Colledan M, D’Antiga L (2012) Feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in children. J Pediatr Gastroenterol Nutr 54(5):594–600PubMedCrossRef
9.
go back to reference Mermuys K, Maleux G, Heye S, Lombaerts R, Nevens F (2008) Use of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation in children: initial clinical experience. Cardiovasc Intervent Radiol 31(Suppl 2):S192–196PubMedCrossRef Mermuys K, Maleux G, Heye S, Lombaerts R, Nevens F (2008) Use of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation in children: initial clinical experience. Cardiovasc Intervent Radiol 31(Suppl 2):S192–196PubMedCrossRef
10.
go back to reference Vo NJ, Shivaram G, Andrews RT, et al. (2012) Midterm follow-up of transjugular intrahepatic portosystemic shunts using polytetrafluoroethylene endografts in children. J Vasc Interv Radiol 23(7):919–924PubMedCrossRef Vo NJ, Shivaram G, Andrews RT, et al. (2012) Midterm follow-up of transjugular intrahepatic portosystemic shunts using polytetrafluoroethylene endografts in children. J Vasc Interv Radiol 23(7):919–924PubMedCrossRef
11.
go back to reference Pillai AK, Joseph AM, Reddick M, Toomay S, Kalva S (2014) Intravascular US-guided transjugular intrahepatic portosystemic shunt creation in a second-trimester pregnancy to prophylactically decompress abdominal wall varices before cesarean section. J Vasc Interv Radiol 25(3):481–483PubMedCrossRef Pillai AK, Joseph AM, Reddick M, Toomay S, Kalva S (2014) Intravascular US-guided transjugular intrahepatic portosystemic shunt creation in a second-trimester pregnancy to prophylactically decompress abdominal wall varices before cesarean section. J Vasc Interv Radiol 25(3):481–483PubMedCrossRef
12.
go back to reference Savage C, Patel J, Lepe MR, Lazarre CH, Rees CR (2007) Transjugular intrahepatic portosystemic shunt creation for recurrent gastrointestinal bleeding during pregnancy. J Vasc Interv Radiol 18(7):902–904PubMedCrossRef Savage C, Patel J, Lepe MR, Lazarre CH, Rees CR (2007) Transjugular intrahepatic portosystemic shunt creation for recurrent gastrointestinal bleeding during pregnancy. J Vasc Interv Radiol 18(7):902–904PubMedCrossRef
13.
go back to reference Arasaratnam P, Low W, Wilkinson N, Felix C, Beri N, Ho H, Foo D, Ong P (2012) Radiation dose in Asia Pacific region—how low can we go? Paper presented at European Society of Cardiology (ESC) Congress, Aug 25–29, Munich, Germany Arasaratnam P, Low W, Wilkinson N, Felix C, Beri N, Ho H, Foo D, Ong P (2012) Radiation dose in Asia Pacific region—how low can we go? Paper presented at European Society of Cardiology (ESC) Congress, Aug 25–29, Munich, Germany
14.
go back to reference Miraglia R, Maruzzelli L, Tuzzolino F, Indovina PL, Luca A (2013) Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system. Cardiovasc Interv Radiol 36(6):1670–1676CrossRef Miraglia R, Maruzzelli L, Tuzzolino F, Indovina PL, Luca A (2013) Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system. Cardiovasc Interv Radiol 36(6):1670–1676CrossRef
15.
go back to reference Suzuki S, Furui S, Kobayashi I, et al. (2005) Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit. Am J Roentgenol 185(4):855–859CrossRef Suzuki S, Furui S, Kobayashi I, et al. (2005) Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit. Am J Roentgenol 185(4):855–859CrossRef
16.
go back to reference Soderman M, Holmin S, Andersson T, et al. (2013) Image noise reduction algorithm for digital subtraction angiography: clinical results. Radiology 269(2):553–560PubMedCrossRef Soderman M, Holmin S, Andersson T, et al. (2013) Image noise reduction algorithm for digital subtraction angiography: clinical results. Radiology 269(2):553–560PubMedCrossRef
Metadata
Title
Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system
Authors
Roberto Miraglia
Luigi Maruzzelli
Kelvin Cortis
Corrado Tafaro
Roberta Gerasia
Carmelo Parisi
Angelo Luca
Publication date
01-08-2015
Publisher
Springer US
Published in
Abdominal Radiology / Issue 6/2015
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-014-0313-8

Other articles of this Issue 6/2015

Abdominal Radiology 6/2015 Go to the issue

Classics in Abdominal Imaging

“Feline” esophagus

Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.